Eaton Crouse-Hinds TECK300 20 Cable Gland - Hazardous Locations
Part Number: TECK300 20
Quick Summary
TECK300 20 cable gland is a rugged aluminum armoured gland designed for TECK armored cable in hazardous locations. This solution helps operators overcome confined-space installation and sealing challenges often faced in harsh environments. The unit aligns with NEC/CEC standards and NEMA 4 enclosure protection, supporting compliant, durable installations. By combining corrosion-resistant construction with precise machining for a 3 in NPT thread and armor range of 2.87–3.19 in and outer sheath range of 3.00–3.27 in, it delivers reliable ingress protection while enabling faster field retrofits. For engineers and procurement teams, this gland translates to reduced downtime, safer commissioning, and smoother maintenance cycles in demanding industrial settings.
Product Information
Extended Description
TECK300 20 Eaton Crouse-Hinds: Eaton Crouse-Hinds series TECK cable gland, TECK armoured cable, Armoured gland, Aluminum, Outer sheath min/max: 3.00-3.27", General purpose, 3" NPT, Armor range min/max: 2.87-3.19"
Product Name
Eaton Crouse-Hinds series TECK cable gland
Catalog Number
TECK300 20
UPC
782274116853
Product Length/Depth
6.4 in
Product Height
5.25 in
Product Width
5.25 in
Product Weight
2.75 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class III
NEMA Rating
4
Protection type
General purpose
Cable type
TECK armored
Gland type
Armoured
Material
Aluminum
Thread Size
3"
Thread type
NPT
Armor (min/max)
2.87-3.19"
Outer sheath (min/max)
3.00-3.27"
Crouse-Hinds series TECK catalog page
IF 1417 - TECK Cable Fittings
Eaton Specification Sheet - TECK300 20
Feature to business impact to application pattern: The TECK300 20 uses aluminum armor-ready construction for rugged, long-life performance, which reduces maintenance costs and downtime in harsh facilities. This improves availability for critical lines and keeps project timelines on track in chemical plants and refineries. It supports TECK armour cable installations with a 3 inch NPT thread, enabling quick, code-compliant connections with existing fittings and minimizing accessory costs during installation. Armoured gland compatibility ensures a tight seal on armor ranging from 2.87 to 3.19 inches, lowering the risk of moisture and dust ingress in hazardous environments. The outer sheath accommodates 3.00 to 3.27 inches, delivering consistent sealing across standard TECK cable diameters and streamlining stock management for procurement teams. By meeting NEC/CEC standards and NEMA 4 protection, this gland reduces regulatory risk while supporting reliable outdoor and wet-location deployments. The product’s area classification for Hazardous/Classified Locations provides confidence for use in Class II Division 1 and Class III zones, enabling safe, compliant operation in mines, paint shops, and similar industries. Together with installation accessories and TECK fittings, it offers a plug-and-play upgrade path that shortens commissioning time and minimizes lifecycle costs. Industry practitioners benefit from first-hand assurances of compatibility with TECK armour cable, while project managers appreciate predictable performance, documented specifications, and reduced variance in field assemblies. This gland is especially advantageous when upgrading legacy systems, where a robust, code-compliant gland prevents costly retrofits and accelerates modernization projects.
Get a Quick Quote for a Eaton Crouse-Hinds TECK300 20
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TECK300 20?
Enquire Now
FAQs
TECK300 20 is designed specifically for TECK armour cable and uses a 3 in NPT thread with aluminum armoured construction. It matches armor range 2.87–3.19 in and outer sheath range 3.00–3.27 in, ensuring a secure, code-compliant fit with standard TECK fittings while maintaining NEMA 4 and NEC/CEC compliance for hazardous environments.
The gland provides an enclosure and seal suitable for Hazardous/Classified Locations and aligns with NEC/CEC standards and area classifications. When installing, verify that the TECK armoured cable diameter matches the armor and sheath ranges, tighten to the specified torque per installation instructions, and use recommended TECK fittings to preserve intrinsic safety and ingress protection.
Yes. The product is designed with a NEMA 4 enclosure rating and hazardous location approvals, which support outdoor and wet environments when installed with compatible TECK fittings. Always confirm the exact installation conditions, seal integrity, and environmental exposure to maintain compliance and performance over time.
TECK300 20 supports NEC/CEC standards and NEMA 4 protection, along with Hazardous/Classified Location area classifications. These certifications reduce regulatory risk, simplify electrical documentation, and streamline approvals for projects in mining, chemical processing, and other demanding sectors.
Upgrading to TECK300 20 offers faster installs with reliable sealing, minimizes downtime during maintenance, and lowers failure-related costs in hazardous areas. The aluminum construction and precise gland dimensions reduce field rework, extend equipment life, and improve overall system reliability in critical processes.