Eaton Crouse-Hinds TMC3-150-2-SS Cable Gland - IP66
Part Number: TMC3-150-2-SS
Quick Summary
TMC3 cable gland ensures rugged sealing for armored and non-armoured cables in hazardous environments. Users often struggle with ingress, corrosion, and downtime when glands fail in harsh plants, especially in classified locations. This gland meets NEC/CEC and IECEx/ATEX certifications and IP66/NEMA 4X protections, ensuring safe operation across global installations. Its armoured and non-armoured options, plus 1-1/2" NPT threading, support fast, reliable installation on existing equipment, reducing commissioning time. By offering broad cable compatibility and durable stainless steel, it helps OEMs and integrators cut spare part counts and maintenance costs while improving overall system reliability.
Product Information
Extended Description
TMC3-150-2-SS Eaton Crouse-Hinds: Eaton Crouse-Hinds series TMC3 cable gland, 1.520" - 2.060" armor min./max., 1.630" - 2.310" cable range min./max., Armoured and non-armoured, Stainless steel, 1.630" - 2.310" outer sheath min./max., Industrial protection, 1-1/2" NPT
Product Name
Eaton Crouse-Hinds series TMC3 cable gland
Catalog Number
TMC3-150-2-SS
UPC
662277130066
Product Length/Depth
6.17 in
Product Height
3.5 in
Product Width
3.5 in
Product Weight
7.01 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IECEx/ATEX
NEC hazardous rating
Class II, Division 1 Class III
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Protection type
Industrial
Gland type
Armoured and non-armoured
Cable type
MC MC-HL TECK TC TC-ER TC-ER-HL ITC ITC-ER ITC-HL PLTC PLTC-ER ACIC
Material
Stainless steel
Thread Size
1-1/2"
Thread type
NPT
Armor (min/max)
1.520" - 2.060"
Cable range (min/max)
1.630" - 2.310"
Outer sheath (min/max)
1.630" - 2.310"
Crouse-Hinds series TMC3 Armored Gland brochure
Crouse-Hinds series TMC3 Armored and Non-armored Cable Glands catalog page
TMC3 Armored Gland ATEX/IECEx certification
TMC3 Armored Gland ATEX/IECEx certification
TMC3 Armored Gland ATEX/IECEx certification
TMC3 Armored Gland ATEX/IECEx certification
TMC3 Armored Gland ATEX/IECEx certification
IF 1890 - TMC3 Cable Gland
Feature: Stainless steel construction provides excellent corrosion resistance in harsh environments. Business Impact: Extends service life and lowers replacement costs in chemical plants, offshore facilities, and outdoor installations. Application: Use in outdoor cabinets and offshore platforms where exposure to moisture and contaminants is high. Feature: Armoured and non-armoured design supports a wide range of cable types. Business Impact: Reduces part numbers needed and simplifies procurement across MC, MC-HL, TECK, TC, TC-ER, ITC families. Application: Ideal for mixed cabling in retrofit projects or new builds with diverse cable inventories. Feature: Large armor and cable ranges (armor 1.520"–2.060", cable 1.630"–2.310", outer sheath 1.630"–2.310"). Business Impact: Enables a single gland to seal multiple cable configurations, decreasing stock and installation time. Application: Fits varied cable assemblies without changing glands. Feature: 1-1/2" NPT thread size with stainless steel construction. Business Impact: Aligns with common enclosure fittings and long-term sealing integrity. Application: Facilitates quick mounting on standard panels and enclosures. Feature: IP66, NEMA 4X protection and hazardous-location ratings. Business Impact: Supports safe operation in Class II, Division 1, and Class III environments; improves compliance posture. Application: Essential for certified installations in hazardous and classified locations. Feature: Documentation and resources from Eaton. Business Impact: Speeds up procurement, verifies installation with IF 1890 instructions, and reduces field errors. Application: Useful for commissioning teams and field service.
Get a Quick Quote for a Eaton Crouse-Hinds TMC3-150-2-SS
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TMC3-150-2-SS?
Enquire Now
FAQs
The gland supports MC, MC-HL, TECK, TC, TC-ER, TC-ER-HL, ITC, ITC-ER, ITC-HL, PLTC, PLTC-ER, and ACIC cables. Choose armoured when external protection or abrasion resistance is required, and non-armoured for standard indoor or well-protected enclosures. Armor range is 1.520"–2.060" and cable range 1.630"–2.310" with an outer sheath similar range, ensuring a secure seal for many installations.
IP66 and NEMA 4X ratings ensure robust ingress protection against dust and water, enabling reliable operation in harsh environments. In hazardous locations, these ratings complement the NEC/CEC and IECEx/ATEX certifications, providing a dependable seal for cables entering enclosures and helping maintain compliance and safety during operation.
Yes. The TMC3-150-2-SS is certified for hazardous/classified locations with NEC/CEC and IECEx/ATEX, and it carries area classification of Hazardous/Classified Locations. The stainless steel construction and gland seal are designed to perform safely in Class II, Division 1 and Class III conditions when used with appropriate cables and enclosures.
Verify NEC/CEC and IECEx/ATEX certification listings, IP66 and NEMA 4X ratings, and the area classification for your installation. The product page includes downloadable certification reports and installation sheets to support your compliance validation and audit trails on site.
Eaton provides brochures, a dedicated TMC3 catalog page, ATEX/IECEx certification PDFs, and IF 1890 installation instructions. Using these resources can shorten lead times, clarify cable compatibility, and guide field technicians through correct gland selection and mounting procedures.