Eaton Crouse-Hinds TMCX050 2 Cable Gland - Explosion-proof
Part Number: TMCX050 2
Quick Summary
Eaton Crouse-Hinds Terminator II TMCX cable gland seals armored cables in hazardous locations. It provides robust, explosion-proof sealing for metal-clad and tray cables while preserving enclosure integrity. The design aligns with NEC/CEC requirements and supports Class I, II, and III hazard classifications, along with NEMA 6P 4X protection for demanding environments. This gland offers straightforward installation, reliable compatibility with 1/2 in NPT fittings, and durable aluminum construction. By choosing this solution, you gain regulatory confidence, reduced maintenance, and a scalable path for cable management in harsh facilities.
Product Information
Extended Description
TMCX050 2 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Terminator II TMCX cable gland,TSC compound,Cable Range:0.65-1.18",Cable Sealing:2 (M),Metal-cladcorrugated armoured,TECK armoured,armoured barrier and tray cable,Armoured gland, Aluminum, 1/2" NPT
Product Name
Eaton Crouse-Hinds series Terminator II TMCX cable gland
Catalog Number
TMCX050 2
UPC
662276298088
Product Length/Depth
4.18 in
Product Height
2.25 in
Product Width
2.25 in
Product Weight
0.95 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
6P 4X
Protection type
Explosion-proof
Cable type
Metal-clad with interlocked or continuously welded corrugated armoured Tray cable TECK armoured Armoured barrier
Gland type
Armoured
Thread Size
1/2"
Thread type
NPT
Cable sealing range
2 (M)
Cable range (min/max)
0.65-1.18"
Material
Aluminum
Barrier type
TSC Compound
Eaton Crouse-Hinds TMCX050 2 3D drawing
Crouse-Hinds series TMCX II brochure
Crouse-Hinds series TMCX II brochure
Crouse-Hinds series TMCX II catalog page
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland UL certification
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland UL certification
IF 1647B - TMCX Terminator II Cable Gland
IF 1647B - TMCX Terminator II Cable Gland
Eaton Specification Sheet - TMCX050 2
Armoured cable compatibility supports metal-clad with interlocked or welded corrugated armour, TECK armoured, and armoured barrier cables. This simplifies procurement and reduces spares while ensuring a reliable seal across the 0.65-1.18 in range, improving field reliability and reducing downtime in critical systems. The 1/2 in NPT aluminum gland balances strength and weight, enabling faster, safer installations in confined panels and rugged environments. The term explosion-proof and NAC/NEC-rated construction means workers meet regulatory requirements with confidence, lowering risk during commissioning and maintenance. The 2 (M) cable sealing capability provides secure ingress protection for larger conductors, minimizing re-entry and resealing costs after cable changes. Together with UL certifications and NEMA 6P 4X protection, this gland delivers long-term cost reduction and improved lifecycle reliability for hazardous locations.
Get a Quick Quote for a Eaton Crouse-Hinds TMCX050 2
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TMCX050 2?
Enquire Now
FAQs
When installing the TMCX050 2, use the 1/2 in NPT threaded fitting on compatible enclosures and ensure the sealing range is appropriate for the conductor size (0.65–1.18 in). Fit the gland to armored or tray cables compatible with metal-clad systems, and tighten to the recommended torque to preserve the explosion-proof integrity. Verify NEC/CEC compliance and ensure enclosure surfaces are clean and undamaged prior to sealing.
The TMCX050 2 carries NEC/CEC standards with a hazardous location rating for Class I, Division 1, Class II, Division 1, and Class III, along with a NEMA 6P 4X protection rating. It is designed for use in hazardous locations and supports UL certification for explosion-proo f applications, giving users confidence in regulatory compliance and field performance.
This gland is designed for metal-clad cables with interlocked or continuously welded corrugated armour, TECK armoured, and armoured barrier cables. It also supports tray cable configurations and provides sealing for the cable range of 0.65–1.18 in with a 2 (M) sealing option, making it suitable for a variety of hazardous-location installations.
Key specs include a 1/2 in NPT thread size, aluminum material, and overall dimensions of approximately 4.18 in length, 2.25 in width, and 2.25 in height, with an approximate weight of 0.95 lb. The gland supports 0.65–1.18 in cable ranges and 2 (M) sealing, making it suitable for armored and barrier cable installations in demanding environments.
The gland delivers improved enclosure integrity and regulatory compliance for hazardous locations, reducing risk of ingress and outages. Its compatibility with multiple armour types lowers inventory complexity, while the explosion-proof design minimizes maintenance downtime and supports faster commissioning, translating to lower total cost of ownership and higher system uptime.