Eaton Crouse-Hinds TMCX075 0 Cable Gland - Explosion-proof
Part Number: TMCX075 0
Quick Summary
TMCX075 0 cable gland from Eaton Crouse-Hinds Terminator II provides explosion-proof sealing for armored cables in hazardous locations. Installers often struggle with ensuring reliable ingress protection, compatibility with multiple armour types, and long service life in confined spaces. This gland aligns with NEC/CEC hazardous location standards and carries a UL certification for explosive atmospheres, plus a NEMA 4X/6P rating for demanding environments. By combining an aluminum body with TECK armouring and interlocked or continuously welded corrugated armour options, it delivers robust performance against moisture, dust, and vibration while simplifying field installations. With a 3/4 in NPT thread and a cable range of 0.45–0.70 in, it supports common industrial cabling in oil, gas, chemical, and mining facilities.
Product Information
Extended Description
TMCX075 0 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Terminator II TMCX cable gland,TSC compound,Cable Range:0.45-0.70",Cable Sealing:0 (XS),Metal-cladcorrugated armoured,TECK armoured,armoured barrier and tray cable,Armoured gland, Aluminum, 3/4" NPT
Product Name
Eaton Crouse-Hinds series Terminator II TMCX cable gland
Catalog Number
TMCX075 0
UPC
662276558601
Product Length/Depth
3.83 in
Product Height
1.63 in
Product Width
1.63 in
Product Weight
4.95 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
4X 6P
Protection type
Explosion-proof
Cable type
Armoured barrier TECK armoured Metal-clad with interlocked or continuously welded corrugated armoured Tray cable
Gland type
Armoured
Thread Size
3/4"
Thread type
NPT
Cable sealing range
0 (XS)
Cable range (min/max)
0.45-0.70"
Material
Aluminum
Barrier type
TSC Compound
Eaton Crouse-Hinds TMCX075 0 3D drawing
Crouse-Hinds series Chico LiquidSeal flyer
Crouse-Hinds series Chico LiquidSeal flyer
Crouse-Hinds series TMCX II catalog page
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland UL certification
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland UL certification
IF 1647 - TMCX Terminator II Cable Gland
IF 1647 - TMCX Terminator II Cable Gland
Eaton Specification Sheet - TMCX075 0
Explosion-proof construction and aluminum body deliver durable protection and safer operation in hazardous areas, reducing maintenance cycles and ensuring long-term reliability for TECK armoured cables in oil, gas, and chemical processing plants. The integrated 3/4 in NPT thread simplifies mounting to standard enclosures, speeding up installation and minimizing field errors, which translates to lower labor costs and faster project completion. Cable sealing range of 0.45–0.70 in kombiniert with 0 (XS) sealing capability provides a precise, moisture-resistant seal across common cabling sizes, improving ingress protection and extending enclosure life. TECK armoured, metal-clad, and interlocked corrugated armour compatibility ensures broad cabling compatibility without sacrificing safety, decreasing inventory complexity and equipment downtime. The Terminator II TMCX series is designed for hazard locations (Class I, Division 1) with NEC/CEC compliance and UL certification, delivering peace of mind and regulatory alignment for critical facilities. Installation and compatibility with armoured barrier and tray cable reduces rework, improves safety margins, and supports scalable growth in mining, chemical, and refinery environments.
Get a Quick Quote for a Eaton Crouse-Hinds TMCX075 0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TMCX075 0?
Enquire Now
FAQs
The TMCX075 0 is designed for Hazardous/Classified Locations (NEC/CEC) with Class I, Division 1 ratings and UL certification. It fits armored barrier and tray cables with a 3/4 in NPT thread, making it ideal for oil, gas, chemical processing, and mining enclosures where explosion protection and reliable seals are critical.
Key specs include an aluminum body, 3/4 in NPT thread, cable sealing range of 0.45–0.70 in, and a protection type of explosion-proof. It supports TECK armour, metal-clad and interlocked corrugated armoured cables, with a 0 (XS) sealing range and a product weight around 4.95 lb for robust field performance.
Yes. The gland is specified for TECK armoured, metal-clad, interlocked or continuously welded corrugated armoured, and tray cables. This broad compatibility reduces inventory needs and simplifies installation across diverse armoured cable types while maintaining a high level of ingress protection.
The TMCX075 0 meets NEC/CEC hazardous location standards with Class I, Division 1 ratings, is UL certified for explosion-proof service, and carries a NEMA 4X 6P rating. These certifications support regulatory compliance and safe operation in harsh industrial environments.
By delivering reliable sealing, corrosion resistance (aluminum body), and compatible armour options, the gland reduces ingress-related failures and maintenance intervals. Its 3/4 in NPT mounting and broad armour compatibility also minimize installation time, lowering labor costs and supporting faster project delivery and long-term uptime in demanding facilities.