Eaton TMCX075 0 L Cable Gland - Explosion-proof
Part Number: TMCX075 0 L
Quick Summary
Cable gland TMCX075 0 L provides explosion‑proof sealing for armored tray cables in hazardous locations. Unsealed penetrations can allow moisture ingress, gas ignition, and costly downtime, making a reliable enclosure seal essential. This unit meets NEC/CEC standards and is rated for Class I, Division 1, Class II, Division 1, and Class III environments, with a NEMA 4X protection rating for rugged outdoor and harsh indoor conditions. The Terminator II design supports TECK armoured tray cables and metal-clad systems, enabling faster, compliant installations in control panels and equipment housings while reducing maintenance costs and downtime. The gland’s liquid barrier and 3/4 inch NPT entry simplify retrofit and new-build projects alike, delivering long-term reliability in industrial wiring.
Product Information
Extended Description
TMCX075 0 L Eaton Crouse-Hinds: Eaton Crouse-Hinds series Terminator II TMCX cable gland,Liquid compound,Cable Range:0.45-0.70",Cable Sealing:0 (XS),Metal-cladcorrugated armoured,TECK armoured,armoured barrier and tray cable,Armoured gland, Aluminum, 3/4" NPT
Product Name
Eaton Crouse-Hinds series Terminator II TMCX cable gland
Catalog Number
TMCX075 0 L
UPC
662276558618
Product Length/Depth
3.83 in
Product Height
1.63 in
Product Width
1.63 in
Product Weight
0.67 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
4X 6P
Protection type
Explosion-proof
Cable type
TECK armoured Tray cable Metal-clad with interlocked or continuously welded corrugated armoured Armoured barrier
Gland type
Armoured
Thread Size
3/4"
Thread type
NPT
Cable sealing range
0 (XS)
Cable range (min/max)
0.45-0.70"
Material
Aluminum
Barrier type
Liquid Compound
Crouse-Hinds series Chico LiquidSeal flyer
Crouse-Hinds series Chico LiquidSeal flyer
Crouse-Hinds series TMCX II catalog page
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland UL certification
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland UL certification
IF 1647 - TMCX Terminator II Cable Gland
IF 1647 - TMCX Terminator II Cable Gland
Eaton Specification Sheet - TMCX075 0 L
Explosion-proof design with a liquid barrier protects energized terminations from ignition sources, reducing the risk of arc and spark propagation in Class I/II environments. This directly translates to lower incident costs and enhanced regulatory compliance, especially in chemical plants and offshore facilities. Applications include TECK armoured tray cables entering control panels and equipment enclosures in hazardous locations. The sealing range accommodates a wide cable diameter (0.45–0.70 in) with an XS seal option, while the standard 3/4 in NPT thread provides a robust entry that aligns with common enclosure fittings, enabling straightforward installation and fewer field adaptations. Aluminum body offers corrosion resistance and lighter weight, improving handling during installation and retrofit and extending service life in humid or coastal environments. Compatibility with TECK armoured tray cables and armoured barrier ensures mechanical protection and reliable sealing for interlocked or welded armour, supported by a liquid compound barrier for tight ingress protection. Certifications include NEC/CEC hazard location ratings, Class I, Division 1; Class II, Division 1; Class III, and a NEMA 4X rating, enabling multi-jurisdictional compliance and streamlined procurement for safety-critical projects. These features collectively reduce maintenance labor, shorten project timelines, and improve overall reliability in hazardous area wiring.
Get a Quick Quote for a Eaton Crouse-Hinds TMCX075 0 L
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TMCX075 0 L?
Enquire Now
FAQs
Begin by selecting the correct gasket or XS seal for the target cable diameter, clean the mating threads, and apply a suitable thread sealant or lubricant compatible with enclosure materials. Thread the gland into the enclosure, torque to manufacturer specifications, and verify the liquid barrier is seated before routing the TECK armoured tray cable into the cable gland. Inspect for any gap or misalignment and perform a functional test to confirm ingress protection and enclosure integrity.
The TMCX075 0 L is designed for TECK armoured tray cables and metal-clad systems with interlocked or welded corrugated armour, including armoured barriers. It covers a cable sealing range of 0.45–0.70 inches, accommodating typical tray and armour variations while maintaining a sealed, hazardous-location-rated entry.
Yes. It is rated for Hazardous/Classified Locations and meets NEC/CEC standards. Certifications include Class I, Division 1; Class II, Division 1; Class III ratings, along with a NEMA 4X protection rating, and UL-listed gland certifications for explosion-proof operation in relevant environments.
Post-installation, perform periodic checks for seal integrity, verify that the liquid barrier remains intact, and confirm there are no signs of corrosion or wear on the aluminum body and armour. Document torque values and inspect the NPT thread engagement during routine enclosure maintenance, especially in challenging environments where exposure to moisture or chemicals is common.
Using the TMCX075 0 L reduces risk of ignition and enclosure ingress, minimizes downtime through reliable sealing, and simplifies multi-jurisdiction compliance with NEC/CEC and UL listings. The NEMA 4X rating supports outdoor and corrosive environments, lowering maintenance costs and extending service life for critical electrical installations in hazardous locations.