Eaton Crouse-Hinds TMCX075 2 Cable Gland - Explosion-Proof

Part Number: TMCX075 2
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
TMCX075 2

Quick Summary

Eaton Crouse-Hinds Terminator II TMCX075 2 cable gland delivers reliable, explosion-proof termination for metal-clad cables in hazardous locations. This gland reduces risk of seal failures and corrosion by delivering a rugged enclosure seal tailored for armoured and tray cables. It complies with NEC/CEC standards, is UL-listed for hazardous locations, and carries a NEMA 4X 6P rating, ensuring dependable performance in demanding environments. The design supports faster installation, reduced maintenance, and longer service life, delivering measurable uptime gains for plants and offshore facilities. For engineers and procurement teams, this gland offers a proven, compatible solution that minimizes inventory complexity while maximizing safety and compliance in critical electrical terminations.

Product Information

Extended Description

TMCX075 2 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Terminator II TMCX cable gland,TSC compound,Cable Range:0.65-1.18",Cable Sealing:2 (M),Metal-cladcorrugated armoured,TECK armoured,armoured barrier and tray cable,Armoured gland, Aluminum, 3/4" NPT
Product Name
Eaton Crouse-Hinds series Terminator II TMCX cable gland
Catalog Number
TMCX075 2
UPC
662276298118
Product Length/Depth
4.18 in
Product Height
2.25 in
Product Width
2.25 in
Product Weight
0.95 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
4X 6P
Protection type
Explosion-proof
Cable type
Metal-clad with interlocked or continuously welded corrugated armoured TECK armoured Tray cable Armoured barrier
Gland type
Armoured
Thread Size
3/4"
Thread type
NPT
Cable sealing range
2 (M)
Cable range (min/max)
0.65-1.18"
Material
Aluminum
Barrier type
TSC Compound
Feature: Explosion-proof aluminum Terminator II TMCX075 2 gland with 3/4" NPT thread. Business Impact: Delivers compliant, rugged terminations for metal-clad and TECK armoured cables, reducing safety risk and commissioning time. Application: Ideal for hazardous locations in process plants and offshore facilities, ensuring reliable enclosure sealing. Long-tail keywords: terminator II gland, armoured cable gland, 3/4 inch NPT gland. Feature: Wide cable range 0.65-1.18" and cable sealing range 2 (M). Business Impact: Supports multiple cable constructions with a single gland, lowering inventory and tool requirements while speeding field installs. Application: Works with TECK armoured, interlocked corrugated armouring, and tray cables. Feature: Barrier and material specs, TSC compound barrier in aluminum gland. Business Impact: Enhances ingress protection and barrier separation, improving long-term reliability in harsh environments. Application: Suitable for armoured barrier and tray cable glands in hazardous zones. Feature: Compliance and certifications, NEC/CEC, UL listings, and NEMA 4X 6P rating. Business Impact: Simplifies regulatory approvals, reduces audit findings, and improves overall plant safety. Application: Ready for hazardous-location installations under multiple standards. Feature: Installation compatibility, standard gland dimensions and 3/4" NPT with 2 (M) sealing. Business Impact: Facilitates quick retrofit and compatibility with existing enclosures, reducing downtime. Application: Widely used in electrical terminations for metal-clad and armoured cables in industrial environments.

Get a Quick Quote for a Eaton Crouse-Hinds TMCX075 2

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds TMCX075 2? Enquire Now

FAQs

For hazardous locations, install the Terminator II TMCX075 2 using the 3/4" NPT thread into approved enclosures designed for armoured cables. The gland supports metal-clad, TECK armoured, and tray cables with a 0.65–1.18" range and 2 (M) sealing, enabling a robust, lossless seal. Use the appropriate sealing compounds and torque specifications from the IF 1647B instructions to ensure integrity under vibration and temperature variations typical of process plants.
Key specs include a cable range of 0.65 to 1.18 inches and a cable sealing range of 2 (M). Thread size is 3/4 inches with an NPT thread type, and the gland is made from aluminum with an armoured barrier (TSC Compound). This combination supports reliable ingress protection and consistent sealing across armoured and tray cable configurations in hazardous locations.
Yes. The TMCX075 2 is designed for metal-clad cables with interlocked or continuously welded corrugated armoured TECK armoured, tray cable, and armoured barrier configurations. Its armoured gland design and barrier type are optimized for hazardous locations, enabling safe termination of TECK armoured and tray cables in enclosures used in Class I, II, and III environments.
The gland aligns with NEC/CEC standards and is rated for Hazardous/Classified Locations. It carries UL certification for explosion-proof use in hazardous environments and a NEMA 4X 6P rating, supporting reliable operation in harsh industrial spaces and offshore facilities.
The Terminator II TMCX075 2 offers durable aluminum construction, robust sealing with 2 (M) seals, and a TSC barrier, which together reduce leak paths and corrosion risk. This translates to lower maintenance intervals, higher uptime, and a favorable total cost of ownership by lowering replacement and inspection frequencies for hazardous-location terminations.