Eaton TMCX075 2 NP Cable Gland - Explosion-Proof
Part Number: TMCX075 2 NP
Quick Summary
TMCX075 2 NP cable gland is explosion-proof sealing for armored cables in hazardous locations. Engineers often wrestle with sealing integrity and installation complexity in demanding environments. This product is NEC/CEC compliant and supports Class I Division 1; Class II Division 1; Class III ratings, with a NEMA 4X 6P enclosure protection baseline. The compact nickel-plated brass gland is designed for TECK armoured cables and a 3/4 in NPT thread, enabling quick, leak-free installs. With robust mechanical protection and clear documentation, you gain predictable maintenance cycles, faster fault isolation, and confident regulatory sign-off for safety-critical systems.
Product Information
Extended Description
TMCX075 2 NP Eaton Crouse-Hinds: Eaton Crouse-Hinds series Terminator II TMCX cable gland,TSC compound,Cable Range:0.65-1.18",Cable Sealing:2 (M),Metal-cladcorrugated armoured,TECK armoured,armoured barrier and tray cable,Armoured gland, Nickel-plated brass, 3/4" NPT
Product Name
Eaton Crouse-Hinds series Terminator II TMCX cable gland
Catalog Number
TMCX075 2 NP
UPC
662276298132
Product Length/Depth
4.18 in
Product Height
2.25 in
Product Width
2.25 in
Product Weight
2.3 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
4X 6P
Protection type
Explosion-proof
Cable type
TECK armoured Metal-clad with interlocked or continuously welded corrugated armoured Tray cable Armoured barrier
Gland type
Armoured
Thread Size
3/4"
Thread type
NPT
Cable sealing range
2 (M)
Cable range (min/max)
0.65-1.18"
Material
Nickel plated brass
Barrier type
TSC Compound
Eaton Crouse-Hinds TMCX075 2 NP 3D drawing
Crouse-Hinds series TMCX II brochure
Crouse-Hinds series TMCX II brochure
Crouse-Hinds series TMCX II catalog page
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland UL certification
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland UL certification
IF 1647B - TMCX Terminator II Cable Gland
IF 1647B - TMCX Terminator II Cable Gland
Eaton Specification Sheet - TMCX075 2 NP
Feature: Explosion-proof, armoured gland with TECK armoured compatibility. Business Impact: Ensures safety compliance and reduces risk of ingress in hazardous zones, lowering potential incident costs. Application: Ideal for power distribution panels in chemical plants and refineries where strict explosion-proof ratings are mandatory. Feature: Cable sealing range and seals. Business Impact: Accommodates a wide range of cable sizes (0.65–1.18 inches) with 2 (M) seals, reducing the need for multiple gland sizes and cutting installation time. Application: Control cabinets and machinery junction boxes in mixed-cable installations. Feature: Threaded connection and durable material. Business Impact: 3/4 inch NPT threads paired with nickel-plated brass provide corrosion resistance and reliable sealing in damp environments, extending component life. Application: Outdoor enclosures and wet plant areas with frequent cleaning cycles. Feature: Armoured barrier and metal-clad options. Business Impact: TECK armoured and metal-clad configurations offer enhanced mechanical protection and EMI shielding, improving system reliability. Application: Heavy-duty industrial facilities with demanding cabling paths. Feature: Certifications and compliance. Business Impact: NEC/CEC alignment, Class I, II, III ratings, and NEMA 4X 6P protection simplify regulatory approvals and project sign-offs. Application: Any hazardous-location installation requiring formal certification and documented compliance. Feature: UL and third-party certification readiness. Business Impact: UL certification support and documented test data streamline supplier approvals and customer audits. Application: Global projects with stringent supplier qualification processes.
Get a Quick Quote for a Eaton Crouse-Hinds TMCX075 2 NP
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TMCX075 2 NP?
Enquire Now
FAQs
The TMCX075 2 NP is designed for TECK armoured cables and features a 3/4 inch NPT thread, ensuring a robust, fit-for-purpose connection in hazardous environments. It accepts a cable range of 0.65 to 1.18 inches with two sealing elements, simplifying on-site selection and reducing the need for multiple gland variations. This compatibility translates to faster commissioning and fewer field modifications.
This gland is rated for explosion-proof service and supports NEC/CEC compliance with NEC hazardous ratings Class I Division 1, Class II Division 1, and Class III. It also carries a NEMA 4X 6P rating, indicating strong enclosure protection. These certifications help ensure safe operation in hazardous locations and streamline regulatory approvals.
Typical applications include control panels, motor starters, and junction cabinets in chemical processing, oil and gas, mining, and other facilities with hazardous locations. The gland’s armoured construction and 3/4" NPT thread make it suitable for demanding environments where cable integrity and environmental protection are critical.
Routine inspection of the sealing elements and the threaded connection is recommended, especially in harsh environments. Since the gland is explosion-proof and nickel-plated brass, check for signs of corrosion or seal wear. Resealing and periodic torque verification are part of standard preventive maintenance to maintain compliance and performance.
By supporting a wide cable range with two seals, 3/4" NPT threads, and rugged armoured protection, the gland reduces part variation, speeds installation, and minimizes resealing incidents. Compliance with NEC/CEC and NEMA 4X 6P lowers audit risk, while reliable sealing reduces downtime, delivering measurable lifecycle savings over complex hazardous-location cabling projects.