Eaton TMCX075 2 NP L Cable Gland - Explosion-proof
Part Number: TMCX075 2 NP L
Quick Summary
The Eaton TMCX075 2 NP L cable gland is a robust, explosion-proof sealing solution for TECK armoured and metal-clad cables used in hazardous locations. Many engineers struggle with maintaining sealing integrity in cramped enclosures while meeting strict NEC/CEC requirements. This gland meets critical safety standards and brings reliable performance to demanding environments. It delivers AREA classification for Hazardous/Classified Locations, UL certification for explosion-proof assemblies, and a NEMA 4X 6P rating, giving long-term protection against dust, moisture, and corrosion. With a nickel-plated brass body and 3/4 inch NPT threads, it offers durable installation and extended service life, supporting efficient asset management and compliant system integration. In addition to safety, it supports faster installs and predictable maintenance cycles.
Product Information
Extended Description
TMCX075 2 NP L Eaton Crouse-Hinds: Eaton Crouse-Hinds series Terminator II TMCX cable gland,Liquid compound,Cable Range:0.65-1.18",Cable Sealing:2 (M),Metal-cladcorrugated armoured,TECK armoured,armoured barrier and tray cable,Armoured gland, Nickel-plated brass, 3/4" NPT
Product Name
Eaton Crouse-Hinds series Terminator II TMCX cable gland
Catalog Number
TMCX075 2 NP L
UPC
662276303690
Product Length/Depth
4.18 in
Product Height
2.25 in
Product Width
2.25 in
Product Weight
2.3 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
4X 6P
Protection type
Explosion-proof
Cable type
TECK armoured Metal-clad with interlocked or continuously welded corrugated armoured Tray cable Armoured barrier
Gland type
Armoured
Thread Size
3/4"
Thread type
NPT
Cable sealing range
2 (M)
Cable range (min/max)
0.65-1.18"
Material
Nickel plated brass
Barrier type
Liquid Compound
Eaton Crouse-Hinds TMCX075 2 NP L 3D drawing
Crouse-Hinds series TMCX II brochure
Crouse-Hinds series TMCX II brochure
Crouse-Hinds series TMCX II catalog page
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland UL certification
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland UL certification
IF 1647 - TMCX Terminator II Cable Gland
IF 1647 - TMCX Terminator II Cable Gland
Eaton Specification Sheet - TMCX075 2 NP L
Feature: Explosion-proof protection type → Business Impact: Ensures safe operation in hazardous environments, reducing the risk of ignition during cable ingress; Application: chemical plants, mining, and offshore facilities. Feature: Cable range 0.65-1.18 inches with cable sealing range 2 (M) → Business Impact: Accommodates common TECK armoured and metal-clad cables, simplifying stocking and field installs; Application: medium-diameter armoured cables in hazardous zones. Feature: Thread Size 3/4 inch NPT → Business Impact: Fits standard enclosure ports, expediting retrofits and new builds; Application: panel and junction box installations. Feature: Material nickel-plated brass → Business Impact: Provides corrosion resistance and durability in harsh environments; Application: chemical processing and outdoor installations. Feature: Barrier type Liquid Compound and Gland type Armoured → Business Impact: Enhanced sealing performance and barrier integrity for continuous-duty service; Application: tray cables in demanding facilities. Feature: Certifications such as NEC/CEC, UL for hazardous locations, and NEMA 4X 6P → Business Impact: Demonstrates regulatory compliance and reliability, reducing certification lead times; Application: qualified for global projects and cross-border procurement.
Get a Quick Quote for a Eaton Crouse-Hinds TMCX075 2 NP L
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TMCX075 2 NP L?
Enquire Now
FAQs
The TMCX075 2 NP L is designed for hazardous locations, including Class I, Division 1 environments, and other NEC/CEC-compliant areas. It uses a 3/4 inch NPT thread and supports TECK armoured, metal-clad, and tray cables. This makes it ideal for chemical plants, refineries, and offshore facilities where reliable sealing and rugged construction are essential.
Key specs include a 3/4 inch NPT thread, nickel-plated brass body, explosion-proof protection, cable range 0.65-1.18 inches, and cable sealing range of 2 (M). The gland supports TECK armoured, metal-clad, and barrier configurations, and has a 4.18 in length, 2.25 in height, 2.25 in width, and a weight of 2.3 lb.
Yes. The TMCX075 2 NP L is specified for TECK armoured and metal-clad cables, including interlocked or continuously welded corrugated armour. It also accommodates armoured barrier and tray cable configurations, providing a versatile sealing solution for different installation architectures.
The gland is compliant with NEC/CEC standards and area classifications for Hazardous/Classified Locations. It carries UL certifications for hazardous locations and a NEMA 4X 6P rating, ensuring weatherproof and corrosion-resistant performance in challenging environments.
The TMCX075 2 NP L delivers durable, corrosion-resistant construction and robust sealing, which reduces ongoing maintenance and seal failures. Its explosion-proof design and proven compliance minimize commissioning time and retrofit risk, delivering a predictable return on investment through improved uptime and lower life-cycle costs.