Eaton Crouse-Hinds TMCX100 1 Cable Gland - Explosion-Proof
Part Number: TMCX100 1
Quick Summary
The TMCX100 1 cable gland from Eaton Crouse-Hinds delivers a reliable, explosion-proof seal for armored cables used in hazardous locations. Engineers often face sealing challenges, corrosion risk, and prolonged downtime when wiring in classified areas. With NEC/CEC compliance and a UL explosion-proof rating, plus NEMA 6P 4X protection, this gland helps ensure safety and long-term reliability. By simplifying installation and ensuring compatible armoured cable types, it supports faster projects and reduces total cost of ownership. Its rugged aluminum body and barrier design stand up to harsh environments found in oil, gas, and chemical processing.
Product Information
Extended Description
TMCX100 1 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Terminator II TMCX cable gland,TSC compound,Cable Range:0.65-1.18",Cable Sealing:1 (S),Metal-cladcorrugated armoured,TECK armoured,armoured barrier and tray cable,Armoured gland, Aluminum, 1" NPT
Product Name
Eaton Crouse-Hinds series Terminator II TMCX cable gland
Catalog Number
TMCX100 1
UPC
662276298149
Product Length/Depth
4.26 in
Product Height
2.25 in
Product Width
2.25 in
Product Weight
0.9 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
6P 4X
Protection type
Explosion-proof
Cable type
Armoured barrier TECK armoured Metal-clad with interlocked or continuously welded corrugated armoured Tray cable
Gland type
Armoured
Thread Size
1"
Thread type
NPT
Cable sealing range
1 (S)
Cable range (min/max)
0.65-1.18"
Material
Aluminum
Barrier type
TSC Compound
Eaton Crouse-Hinds TMCX100 1 3D drawing
Crouse-Hinds series Chico LiquidSeal flyer
Crouse-Hinds series Chico LiquidSeal flyer
Crouse-Hinds series TMCX II catalog page
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland UL certification
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland UL certification
IF 1647B - TMCX Terminator II Cable Gland
IF 1647B - TMCX Terminator II Cable Gland
Eaton Specification Sheet - TMCX100 1
Feature: 1 inch NPT thread and armoured gland form a robust mechanical interface. Business Impact: reduces installation time and potential leak paths by providing a secure, code-compliant connection for shielded and shielded-tray cables. Application: ideal for armored barrier and tray cable systems in hazardous locations. The benefit is faster field termination with fewer rework incidents, improving project timelines and safety compliance. Long-tail keywords: explosion-proof cable gland, 1 inch NPT gland, armored barrier gland. Feature: Cable sealing range 0.65–1.18 inches with a 1 (S) sealing configuration. Business Impact: ensures proper sealing for a wide range of conductor sizes, lowering spare-part complexity and avoiding oversized fittings. Application: supports mixed-cabling installations in process plants and mining facilities. Long-tail keywords: cable sealing range, TECK armoured compatibility, tray cable gland. Feature: Material and barrier technology: aluminum housing with TSC barrier compound. Business Impact: delivers lightweight but durable protection that maintains integrity under electrical stress, reducing maintenance intervals. Application: use in environments requiring explosion-proof, corrosion-resistant enclosures. Long-tail keywords: aluminum gland, TSC barrier, explosion-proof enclosure. Feature: Cable types supported: armoured barrier, TECK armoured, metal-clad with interlocked or continuously welded corrugated armour, and tray cable. Business Impact: broad compatibility lowers part diversity, enabling one gland to cover multiple installation regimes. Application: suitable for TECK armour, metal-clad, and tray-cable runs in hazardous areas. Long-tail keywords: TECK armoured cable gland, metal-clad gland, tray cable gland. Feature: Certifications and compliance: NEC/CEC standards, NEC hazardous rating Class I, Division 1; Class II, Division 1; Class III; NEMA 6P 4X; UL explosion-proof certification. Business Impact: ensures regulatory compliance, reduces risk of non-conformance penalties, and supports third-party audits. Application: critical for refinery, chemical, and offshore facilities. Long-tail keywords: NEC/CEC compliance, hazardous location ratings, UL certified gland. Feature: Installation resources and documentation: IF 1647B/IF 1647 instruction sheets and specification sheets available. Business Impact: accelerates correct installation, verifies wiring methods, and decreases commissioning delays. Application: field technicians in industrial plants rely on precise guidance for safe termination. Long-tail keywords: installation instructions, IF 1647B, terminator II gland guidance.
Get a Quick Quote for a Eaton Crouse-Hinds TMCX100 1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TMCX100 1?
Enquire Now
FAQs
The TMCX100 1 is designed to accommodate TECK armoured, metal-clad, and interlocked or welded corrugated armour, as well as tray cables. This ensures a single gland can cover multiple installation scenarios, reducing part variety and speeding procurement. The gland’s aluminum housing maintains strength while keeping weight manageable for field installation.
The gland carries NEC/CEC compliance and NEC hazardous ratings of Class I, Division 1; Class II, Division 1; Class III, along with a NEMA 6P 4X rating and UL explosion-proof certification. These certifications validate safe operation in hazardous areas, support regulatory audits, and help prevent non-conformance penalties in oil, gas, and chemical facilities.
Key specs include a 1" NPT thread size, aluminum body, and cable sealing range of 0.65–1.18 inches with a 1 (S) seal. The product length is 4.26 in, height 2.25 in, width 2.25 in, and weight 0.9 lb, providing a compact yet rugged gland suitable for tight enclosures and difficult cable routes.
Yes. Installation sheets IF 1647B and IF 1647B cover Terminator II TMCX installation procedures, with additional Eaton literature and datasheets available online. Following these guides ensures correct cable termination, field wiring practices, and compliance with local electrical codes during commissioning.
Choosing the TMCX100 1 delivers enhanced safety through proven explosion-proof design, regulatory compliance with NEC/CEC and UL certification, and reduced installation time due to broad compatibility with armoured and tray cables. This leads to lower lifecycle costs, fewer field errors, and faster throughput on projects in hazardous environments.