Eaton Crouse-Hinds TMCX100 1 SS L Gland - Explosion-Proof
Part Number: TMCX100 1 SS L
Quick Summary
The TMCX100 1 SS L cable gland from Eaton Crouse-Hinds provides explosion-proof cable termination for hazardous locations. Engineers struggle with moisture ingress, seals failures, and compliance risk in harsh environments, causing downtime and maintenance costs. It meets NEC/CEC compliance and hazardous-location ratings—Class I, Division 1; Class II, Division 1; Class III—and NEMA 4X 6P, ensuring reliable performance in demanding areas. This solution simplifies armoured TECK/tray cable installations and reduces inventory, delivering long-term cost savings for industrial automation projects. Its stainless steel body delivers corrosion resistance in chemical and outdoor environments, while the 1" NPT threaded gland and 0.65–1.18" cable range support flexible installations across TECK-armoured tray cables and metal-clad conductors. Users gain faster compliance validation through documented UL/UL-listed certifications and installation sheets included in the downloads.
Product Information
Extended Description
TMCX100 1 SS L Eaton Crouse-Hinds: Eaton Crouse-Hinds series Terminator II TMCX cable gland,Liquid compound,Cable Range:0.65-1.18",Cable Sealing:1 (S),Metal-cladcorrugated armoured,TECK armoured,armoured barrier and tray cable,Armoured gland, Stainless steel, 1" NPT
Product Name
Eaton Crouse-Hinds series Terminator II TMCX cable gland
Catalog Number
TMCX100 1 SS L
UPC
662276303713
Product Length/Depth
4.26 in
Product Height
2.25 in
Product Width
2.25 in
Product Weight
1.84 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
4X 6P
Protection type
Explosion-proof
Cable type
TECK armoured Tray cable Metal-clad with interlocked or continuously welded corrugated armoured Armoured barrier
Gland type
Armoured
Thread Size
1"
Thread type
NPT
Cable sealing range
1 (S)
Cable range (min/max)
0.65-1.18"
Material
Stainless steel
Barrier type
Liquid Compound
Eaton Crouse-Hinds TMCX100 1 SS L 3D drawing
Crouse-Hinds series TMCX II brochure
Crouse-Hinds series TMCX II brochure
Crouse-Hinds series TMCX II catalog page
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland UL certification
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland UL certification
IF 1647 - TMCX Terminator II Cable Gland
IF 1647 - TMCX Terminator II Cable Gland
Eaton Specification Sheet - TMCX100 1 SS L
Explosion-proof design and stainless steel construction deliver rugged, durable terminations for hazardous locations, reducing ignition risk and enhancing personnel safety in chemical plants, refineries, and mining operations. The gland supports flexible TECK armoured tray cables with a 1" NPT thread and a cable range of 0.65–1.18 inches, simplifying procurement and reducing the number of gland variants needed on site. Compatibility with TECK armoured tray cables and metal-clad conductors provides robust sealing against moisture, dust, and corrosive elements, extending equipment life and lowering maintenance costs in outdoor or challenging environments. Compliance with NEC/CEC and hazards-location ratings—Class I Division 1, Class II Division 1, Class III—and NEMA 4X 6P streamlines audits, enabling smoother project approvals and regulatory confidence. Documentation and install support, including UL certification references, 3D CAD drawings, IF1647 installation sheets, and catalogs, accelerate engineering workflows and reduce field rework, delivering measurable productivity gains for engineering and procurement teams.
Get a Quick Quote for a Eaton Crouse-Hinds TMCX100 1 SS L
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TMCX100 1 SS L?
Enquire Now
FAQs
The gland uses 1" NPT threads and is designed for TECK armoured tray cables and metal-clad conductors with interlocked or welded armour. Install per IF 1647 instructions and ensure proper sealing range 1(S) to meet the application needs.
It carries NEC/CEC compliance with Class I, Division 1; Class II, Division 1; Class III ratings, and a NEMA 4X 6P enclosure rating, suitable for hazardous and classified locations in harsh environments.
Yes. The explosion-proof stainless steel Terminator II gland is designed for hazardous-area terminations and supports TECK armoured and metal-clad cables, with documentation and UL certifications to support installation in oil, gas, and chemical processing facilities.
Included are UL certification reports, IF 1647 installation instructions, installation sheets, a 3D CAD drawing package, a catalog page, and the Eaton specification sheet to streamline design reviews and field assembly.
Expect reduced maintenance and downtime due to robust seals and corrosion resistance, faster approvals with recognized NEC/CEC and UL certifications, fewer gland variants needed thanks to flexible cable range, and improved installation efficiency through readily available CAD drawings and installation sheets.