Eaton Crouse-Hinds Cable Gland TMCX125 2 L - Explosionproof
Part Number: TMCX125 2 L
Quick Summary
The TMCX125 2 L explosion-proof TECK armoured cable gland securely seals armored cables in hazardous locations. Installers often struggle with reliable seals under vibration, chemical exposure, and tight spaces. This gland meets NEC/CEC standards and hazardous-location ratings, including Class I, Division 1, Class II, Division 1, Class III, with NEMA 4X 6P protection for added resilience. Designed for aluminum construction and TECK armour, it accommodates a 1-1/4" NPT thread, enabling quick, compliant installations and long service life. This gland reduces maintenance downtime and regulatory risk while supporting scalable compatibility with tray cables and armoured barriers, helping manufacturers improve uptime across plant floors.
Product Information
Extended Description
TMCX125 2 L Eaton Crouse-Hinds: Eaton Crouse-Hinds series Terminator II TMCX cable gland,Liquid compound,Cable Range:1.03-1.71",Cable Sealing:2 (M),Metal-cladcorrugated armoured,TECK armoured,armoured barrier and tray cable,Armoured gland, Aluminum, 1-1/4" NPT
Product Name
Eaton Crouse-Hinds series Terminator II TMCX cable gland
Catalog Number
TMCX125 2 L
UPC
662276438354
Product Length/Depth
5.96 in
Product Height
3.73 in
Product Width
3.73 in
Product Weight
7.42 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
4X 6P
Protection type
Explosion-proof
Cable type
TECK armoured Metal-clad with interlocked or continuously welded corrugated armoured Armoured barrier Tray cable
Gland type
Armoured
Thread Size
1-1/4"
Thread type
NPT
Cable sealing range
2 (M)
Cable range (min/max)
1.03-1.71"
Material
Aluminum
Barrier type
Liquid Compound
Crouse-Hinds series TMCX II brochure
Crouse-Hinds series TMCX II brochure
Crouse-Hinds series TMCX II catalog page
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland UL certification
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland UL certification
IF 1647 - TMCX Terminator II Cable Gland
IF 1647 - TMCX Terminator II Cable Gland
Eaton Specification Sheet - TMCX125 2 L
Feature: Explosion-proof construction with aluminum TECK armoured cable gland provides a safe, compliant entry point for power and control cables. Business Impact: Reduces ignition risk and non-compliance penalties in hazardous locations while meeting NEC/CEC requirements. Application: Ideal for chemical plants, oil and gas facilities, and mining operations where ignition hazards are present. Feature: 1-1/4" NPT thread standardizes mounting with common enclosures. Business Impact: Accelerates installation, reduces tooling needs, and lowers field labor costs. Application: Panel entries and control cabinets requiring a stable gland interface. Feature: Cable sealing range 2 (M) and cable range 1.03-1.71" provide flexibility. Business Impact: Minimizes SKU proliferation and simplifies procurement. Application: TECK armoured, metal-clad, armoured barrier and tray cables. Feature: Aluminum housing with liquid barrier compound provides corrosion resistance and rugged outdoors performance. Business Impact: Extends service life in wet, dusty, or corrosive environments, lowering replacement cycles. Application: Outdoor installations and harsh indoor environments. Feature: Certifications and compliance including NEC hazardous ratings Class I, Division 1; Class II, Division 1; Class III and NEMA 4X 6P. Business Impact: Assurance for regulatory audit readiness and worker safety. Application: Any hazardous-location project requiring strict compliance. Feature: Compatibility with interlocked or welded corrugated armour, armoured barrier and tray cable, and rapid retrofit capability. Business Impact: Enables quick upgrades and minimal downtime during plant modernization. Application: Retrofitting existing systems or new installations in process industries.
Get a Quick Quote for a Eaton Crouse-Hinds TMCX125 2 L
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TMCX125 2 L?
Enquire Now
FAQs
For safe, compliant installation, verify enclosure compatibility with a 1-1/4" NPT gland, ensure proper torque on the gland thread, and ensure the connected TECK armoured or metal-clad cable is within the 1.03–1.71" range. Use appropriate sealing compounds and follow manufacturer torque guidelines to maintain the Class I, Division 1 ratings.
The gland is designed for TECK armoured, metal-clad cables, including interlocked or welded corrugated armour, armoured barrier, and tray cables. It supports a cable range of 1.03 to 1.71 inches with a sealing range of 2 (M), enabling a single gland to cover multiple cable diameters and reducing stocking requirements.
The TMCX125 2 L carries NEC/CEC compliance with hazardous-location ratings Class I, Division 1, Class II, Division 1, and Class III, plus a NEMA 4X 6P protection rating. It is suitable for Hazardous/Classified Locations, aligning with industry safety and regulatory expectations for critical process environments.
Yes. It is compatible with TECK armoured cables and metal-clad options, including interlocked or welded corrugated armour, armour barriers, and tray cables. This compatibility allows quick retrofits or new installations without additional adapters, streamlining project timelines and reducing downtime.
The gland offers robust sealing that minimizes ignition risk, reduces maintenance cycles, and shortens installation times. By consolidating cable types into a single, compliant gland, it lowers inventory costs and simplifies regulatory audits, delivering tangible uptime gains and lower total cost of ownership over the equipment’s life cycle.