Eaton TMCX150 1 NP L Cable Gland - Explosion Proof
Part Number: TMCX150 1 NP L
Quick Summary
TMCX150 1 NP L cable gland is a rugged termination for explosion-proof, hazardous-location wiring. Engineers often struggle with sealing integrity and corrosion resistance in harsh environments, especially when servicing TECK armoured or metal-clad cables in cramped spaces. This Terminator II gland meets NEC/CEC requirements and UL certifications for hazardous areas while delivering robust NEMA 4X protection. By combining a durable nickel-plated brass gland with a proven barrier design, it ensures reliable performance, long service life, and predictable maintenance cycles for your automation and electrical installations in challenging plants and facilities.
Product Information
Extended Description
TMCX150 1 NP L Eaton Crouse-Hinds: Eaton Crouse-Hinds series Terminator II TMCX cable gland,Liquid compound,Cable Range:1.03-1.71",Cable Sealing:1 (S),Metal-cladcorrugated armoured,TECK armoured,armoured barrier and tray cable,Armoured gland, Nickel-plated brass, 1-1/2" NPT
Product Name
Eaton Crouse-Hinds series Terminator II TMCX cable gland
Catalog Number
TMCX150 1 NP L
UPC
662276441446
Product Length/Depth
5.96 in
Product Height
3.73 in
Product Width
3.73 in
Product Weight
15.24 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
4X
Protection type
Explosion-proof
Cable type
TECK armoured Tray cable Armoured barrier Metal-clad with interlocked or continuously welded corrugated armoured
Gland type
Armoured
Thread Size
1-1/2"
Thread type
NPT
Cable sealing range
1 (S)
Cable range (min/max)
1.03-1.71"
Material
Nickel plated brass
Barrier type
Liquid Compound
Eaton Crouse-Hinds TMCX150 1 NP L 3D drawing
Crouse-Hinds series TMCX II brochure
Crouse-Hinds series TMCX II brochure
Crouse-Hinds series TMCX II catalog page
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland UL certification
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland UL certification
IF 1647 - TMCX Terminator II Cable Gland
IF 1647 - TMCX Terminator II Cable Gland
Eaton Specification Sheet - TMCX150 1 NP L
Feature → 1-1/2 inch NPT threaded armoured gland provides rugged ingress protection and compatibility with TECK armoured cables. Business impact → Delivers reliable seal integrity under vibration and temperature swings, reducing field adjustments and maintenance costs. Application → Suitable for explosion-proof equipment and metal-clad systems in hazardous-location installations such as refineries, chemical plants, and mining sites. Feature → Cable sealing range 1.03–1.71 inches and sealing capacity 1 (S) support a wide cable footprint. Business impact → Accommodates a broad range of cable diameters without gland changes, shortening project timelines and minimizing stock variety. Application → Ideal for power and control cables in TECK armoured and tray cable configurations. Feature → Nickel-plated brass construction with a liquid compound barrier delivers corrosion resistance and robust environmental sealing. Business impact → Extends service life in washdowns, chemical exposure, and outdoor installations, reducing replacement intervals. Application → Offshore platforms, chemical processing, and other harsh environments requiring durable gland assemblies. Feature → Hazardous/classified locations certification with NEC/CEC standards and Class I, II, III ratings; NEMA 4X protection. Business impact → Ensures regulatory compliance, simplifies procurement, and mitigates non-conformance risk. Application → Oil & gas, mining, and energy sectors where safe termination in hazardous areas is mandatory. Feature → Comprehensive installation resources including 3D CAD drawings, installation sheets, and UL references. Business impact → Speeds design-in, reduces errors, and improves commissioning efficiency. Application → Streamlines engineering workflows for panel builders deploying Terminator II TMCX glands across projects.
Get a Quick Quote for a Eaton Crouse-Hinds TMCX150 1 NP L
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TMCX150 1 NP L?
Enquire Now
FAQs
The gland uses a 1-1/2 inch NPT thread and supports TECK armoured and metal-clad cables, with a sealing range of 1.03–1.71 inches. For hazardous locations, ensure alignment with NEC/CEC requirements and proper mounting to maintain NEMA 4X protection. UL documentation is available for certified configurations, aiding expedited installation in plants.
The device delivers a cable sealing range of 1.03–1.71 inches and a sealing capacity of 1 (S), enabling a broad spectrum of cable diameters without swapping glands. This reduces part diversity, speeds field installation, and minimizes retrofit risk in evolving automation systems.
Yes. The gland is designed for Hazardous/Classified Locations with NEC/CEC compliance and Class I, Division 1 ratings, along with a NEMA 4X protection level, making it appropriate for oil & gas, chemical processing, and mining applications where explosive atmospheres are a concern.
The TMCX150 aligns with NEC/CEC standards, Class I, Division 1/II, Class III ratings, and NEMA 4X protection. UL certification references and installation sheets (IF 1647 and related resources) are available to validate compliance and simplify supplier audits during project commissioning.
In addition to standard installation instructions, 3D CAD drawings and a full catalog of brochures and datasheets are available, reducing design time and helping integrators verify fitment and clearance before procurement, thereby lowering lifecycle costs and accelerating time-to-operation.