Eaton Crouse-Hinds TMCX150 2 SS L Cable Gland - Explosion-proof
Part Number: TMCX150 2 SS L
Quick Summary
Eaton Crouse-Hinds TMCX150 2 SS L Cable Gland is an explosion-proof solution for hazardous-area electrical installations. Maintenance teams often confront ingress, corrosion, and sealing failures in harsh environments. The device carries NEC/CEC compliance with Hazardous/Classified Locations area classifications and a NEMA 4X rating, ensuring safety and audit readiness. Its stainless-steel construction is ideal for TECK armoured, barrier, and tray cables, delivering reliable sealing, installer-friendly fit, and long-term cost savings across demanding industrial facilities.
Product Information
Extended Description
TMCX150 2 SS L Eaton Crouse-Hinds: Eaton Crouse-Hinds series Terminator II TMCX cable gland,Liquid compound,Cable Range:1.42-2.07",Cable Sealing:2 (M),Metal-cladcorrugated armoured,TECK armoured,armoured barrier and tray cable,Armoured gland, Stainless steel, 1-1/2" NPT
Product Name
Eaton Crouse-Hinds series Terminator II TMCX cable gland
Catalog Number
TMCX150 2 SS L
UPC
662276507777
Product Length/Depth
5.96 in
Product Height
4.11 in
Product Width
4.11 in
Product Weight
18.54 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
4X
Protection type
Explosion-proof
Cable type
TECK armoured Armoured barrier Tray cable Metal-clad with interlocked or continuously welded corrugated armoured
Gland type
Armoured
Thread Size
1-1/2"
Thread type
NPT
Cable sealing range
2 (M)
Cable range (min/max)
1.42-2.07"
Material
Stainless steel
Barrier type
Liquid Compound
Eaton Crouse-Hinds TMCX150 2 SS L 3D drawing
Crouse-Hinds series Chico LiquidSeal flyer
Crouse-Hinds series Chico LiquidSeal flyer
Crouse-Hinds series TMCX II catalog page
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland UL certification
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland UL certification
IF 1647 - TMCX Terminator II Cable Gland
IF 1647 - TMCX Terminator II Cable Gland
Eaton Specification Sheet - TMCX150 2 SS L
Feature: Explosion-proof construction provides intrinsic safety for penetrations in hazardous locations. The design contains arcs and heat within approved enclosures, reducing ignition risk. Application: chemical plants, refineries, and offshore installations require this level of protection for reliable operations. Feature: TECK armoured and metal-clad compatibility supports interlocked or welded corrugated armour. Business Impact: delivers rugged mechanical protection and simplifies installation in tight or congested penetrations. Application: armored cable runs in heavy industrial settings such as mining, petrochem, and steel plants. Feature: Stainless steel material delivers exceptional corrosion resistance and heat tolerance. Business Impact: extends service life, lowers replacement costs, and reduces maintenance frequency in washdown and coastal environments. Application: chemical processing, water treatment, and offshore facilities where exposure to moisture and chemicals is constant. Feature: Sealing range of 2 (M) and cable range of 1.42-2.07 inches provide a tight ingress seal for varied cable diameters. Business Impact: minimizes water and dust ingress, improving reliability and reducing gasket failures. Application: mixed-cable penetrations and barrier installations across hazardous zones. Feature: Certifications and installation resources, including NEC/CEC compliance, HazLoc ratings, and NEMA 4X, plus IF 1647 instruction sheets and 3D CAD drawings. Business Impact: supports faster design reviews, smoother procurement, and compliant commissioning. Application: engineering design, procurement, and field installation in hazardous locations. Feature: Thread size 1-1/2 inch NPT and compact footprint of 5.96 in length by 4.11 in square enable straightforward compatibility with standard conduit systems. Business Impact: reduces integration risk, speeds installation, and minimizes field modification. Application: retrofit projects and new-build installations in demanding facilities.
Get a Quick Quote for a Eaton Crouse-Hinds TMCX150 2 SS L
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TMCX150 2 SS L?
Enquire Now
FAQs
For proper installation, verify 1-1/2 inch NPT thread engagement and ensure the gland is used with TECK armoured or metal-clad cables. Consult IF 1647 instructions and use the 2 (M) cable sealing range to achieve a tight seal. Utilize the 3D CAD drawings when planning penetrations to minimize interference with surrounding equipment.
The TMCX150 2 SS L meets NEC/CEC standards and is rated for Hazardous/Classified Locations with Class I, Division 1, Class II, Division 1, and Class III ratings. It carries a NEMA 4X protection class and UL certifications for explosion-proof operation in demanding environments.
Yes. The gland is designed for TECK armoured, armoured barrier, and tray cable configurations, including metal-clad armour variants. Its 1-1/2" NPT thread and stainless-steel construction provide a robust, serviceable solution for armored cable penetrations in harsh industrial settings.
Ideal for chemical plants, refineries, offshore platforms, and other hazardous locations where armored cables must penetrate enclosures while maintaining ingress protection and corrosion resistance. It supports reliable operation in washdown zones and environments with exposure to moisture and chemicals.
Long-term cost savings come from extended service life due to stainless steel construction, reduced maintenance frequency, and lower risk of sealing failures in harsh environments. The gland’s compliance and readily available installation resources also reduce commissioning time and audit-related expenses.