Eaton TMCX200 Terminator II Cable Gland - Explosion-Proof

Part Number: TMCX200 1 SS L
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
TMCX200 1 SS L

Quick Summary

Eaton TMCX200 Terminator II cable gland seals cables in hazardous locations. This is a common pain point for engineers who must prevent ignition risks while minimizing downtime and cost. It delivers NEC/CEC compliance with Class I, II, and III hazardous locations and a robust NEMA 4X rating. Featuring stainless steel construction and TECK armoured compatibility, it supports long-term performance and easier installation. For procurement teams, the unit reduces spare parts and risk while meeting regulatory and uptime targets. Trust in its 2" NPT thread and stainless steel gasket arrangement to minimize ingress risk across oil, gas, and chemical processing facilities.

Product Information

Extended Description

TMCX200 1 SS L Eaton Crouse-Hinds: Eaton Crouse-Hinds series Terminator II TMCX cable gland,Liquid compound,Cable Range:1.42-2.07",Cable Sealing:1 (S),Metal-cladcorrugated armoured,TECK armoured,armoured barrier and tray cable,Armoured gland, Stainless steel, 2" NPT
Product Name
Eaton Crouse-Hinds series Terminator II TMCX cable gland
Catalog Number
TMCX200 1 SS L
UPC
662276508385
Product Length/Depth
5.96 in
Product Height
4.11 in
Product Width
4.11 in
Product Weight
17.64 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
4X
Protection type
Explosion-proof
Cable type
TECK armoured Tray cable Armoured barrier Metal-clad with interlocked or continuously welded corrugated armoured
Gland type
Armoured
Thread Size
2"
Thread type
NPT
Cable sealing range
1 (S)
Cable range (min/max)
1.42-2.07"
Material
Stainless steel
Barrier type
Liquid Compound
Explosion-proof protection type ensures safe operation in hazardous locations, reducing ignition risks and enabling NEC/CEC compliance. The TMCX200's stainless steel body delivers rugged durability, resisting corrosion and mechanical abuse while maintaining a reliable seal under vibration and temperature swings. In field applications such as refineries, chemical plants, offshore platforms, and mining sites, this gland supports TECK armoured and metal-clad cables with interlocked or welded armour, ensuring dependable performance across demanding environments and retrofit projects. Wide cable range compatibility simplifies procurement and installation. The gland accepts 1.42-2.07 in cables with a 1 (S) sealing option, including TECK armoured tray cables and barrier configurations. This range reduces spare parts inventory, minimizes re-terminations, and speeds commissioning across multi-cable systems in harsh environments. Durable stainless steel construction and armoured barrier design offer long-term protection in abrasive and chemically challenging settings. The barrier type uses a Liquid Compound to seal and isolate energized conductors, enhancing ingress protection and reliability. With NEC hazardous ratings and NEMA 4X protection, the gland is suited for Class I, II, and III locations, enabling safer operation in dust, moisture, and corrosive atmospheres. Installation is streamlined by a standard 2" NPT thread and compatible gland sealing arrangements, enabling fast, leak-free mounting on a wide range of enclosures. The unit's compatibility with TECK armoured trays and metal-clad cables reduces the need for adapters and extra hardware, cutting installation time in the plant and field upgrades. Comprehensive documentation and CAD resources (IF 1647 instructions and 3D drawings) support accurate planning and compliant retrofits. In regulated facilities, reliable explosion-proof glands are a strategic asset for uptime and safety, supported by UL certification and formal NEC/CEC compliance. The TMCX II Series, including TMCX200 1 SS L, offers traceability through UPC and catalog pages, simplifying audits and asset management. By aligning with hazardous location standards and providing durable, easy-to-install protection, it delivers measurable cost savings over glands with shorter service life.

Get a Quick Quote for a Eaton Crouse-Hinds TMCX200 1 SS L

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds TMCX200 1 SS L? Enquire Now

FAQs

For safe installation in hazardous locations, follow the IF 1647 installation guidelines and use the 2" NPT thread with the stainless steel sealing gasket. Verify cable range compatibility (1.42-2.07 in) and ensure TECK armoured or metal-clad cables are correctly seated with the 1 (S) seal. Confirm ingress protection and torque specifications for a reliable, compliant seal.
The TMCX200 is rated for NEC/CEC compliance with Class I, II, and III hazardous locations and carries a NEMA 4X protection rating. It is designed for explosion-proof service in Hazardous/Classified Locations, aligning with UL certifications. This combination supports regulatory audits and safe operation in mining, chemical processing, and oil & gas environments.
Yes. The gland is specified for TECK armoured tray cables and armoured barrier configurations, including metal-clad systems with interlocked or welded armour. This compatibility reduces required adapters, simplifies field retrofits, and ensures a secure, compliant connection for heavily armoured cabling in demanding plants.
The 1 (S) sealing range with a 1.42-2.07 in cable range accommodates several cable sizes without multiple glands. The standard 2" NPT thread enables broad enclosure compatibility and quick mounting, reducing installation time and potential leaks. Together, they support rapid commissioning and reliable performance in harsh industrial settings.
Long-term ROI comes from the gland’s corrosion resistance, explosion-proof protection, and 4X-like durability, which reduce replacement frequency and maintenance costs. The wide cable range minimizes spare parts, while its robust sealing reduces downtime during inspections. Overall, the gland contributes to safer operations, shorter audits, and steady uptime in regulated facilities.