Eaton TMCX200 2 Cable Gland - Explosion-proof 4X
Part Number: TMCX200 2
Quick Summary
Cable gland Terminator II TMCX200 2 seals armored cables for hazardous locations. Operators and maintenance teams struggle with seal degradation and ignition risk in harsh environments. This unit meets Hazardous/Classified Locations area classifications, NEC/CEC standards, and NEMA 4X protection, ensuring compliance and durability. Designed for quick installation on 2 inch NPT glands, it supports armored and TECK armoured cables, reducing downtime. With aluminum construction and a robust barrier material, it delivers long-term performance and cost savings for critical facilities.
Product Information
Extended Description
TMCX200 2 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Terminator II TMCX cable gland,TSC compound,Cable Range:1.81-2.72",Cable Sealing:2 (M),Metal-cladcorrugated armoured,TECK armoured,armoured barrier and tray cable,Armoured gland, Aluminum, 2" NPT
Product Name
Eaton Crouse-Hinds series Terminator II TMCX cable gland
Catalog Number
TMCX200 2
UPC
662276440289
Product Length/Depth
6.88 in
Product Height
4.98 in
Product Width
4.98 in
Product Weight
12.2 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
4X
Protection type
Explosion-proof
Cable type
Armoured barrier Tray cable TECK armoured Metal-clad with interlocked or continuously welded corrugated armoured
Gland type
Armoured
Thread Size
2"
Thread type
NPT
Cable sealing range
2 (M)
Cable range (min/max)
1.81-2.72"
Material
Aluminum
Barrier type
TSC Compound
Eaton Crouse-Hinds TMCX200 2 3D drawing
Crouse-Hinds series Chico LiquidSeal flyer
Crouse-Hinds series Chico LiquidSeal flyer
Crouse-Hinds series TMCX II catalog page
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland Canadian certification
TMCX II Explosionproof Armoured Barrier and Non-armoured Barrier Gland Canadian certification
IF 1647B - TMCX Terminator II Cable Gland
IF 1647B - TMCX Terminator II Cable Gland
Eaton Specification Sheet - TMCX200 2
Explosion-proof protection provides certified safety for hazardous locations, reducing ignition risk and downtime. In oil, gas, chemical processing, and mining facilities, uninterrupted seals directly translate to safer operations and reduced insurance costs. The TMCX200 2 Terminator II is engineered for 2 inch NPT glands and armoured barrier or TECK armoured cables, delivering compliant performance across NEC/CEC and NEMA 4X environments. Armoured barrier compatibility expands installation options by delivering a robust seal on metal-clad cables with interlocked or welded corrugated armour, as well as tray cables. The aluminum body combines corrosion resistance with light weight, simplifying field mounting and reducing fatigue on technicians during installation. This combination supports both retrofit upgrades and new-build projects, accelerating commissioning and minimizing electrical installation risk. Sealing range of 1.81–2.72 inches and a 2M sealing capacity cover the majority of industrial cables without bespoke adaptors, streamlining procurement. The gland’s 2" thread size and NPT thread type align with common enclosure fittings, reducing the need for specialty hardware. Operators can expect consistent compression and reliable ingress protection even under vibration and temperature cycling. From a maintenance perspective, the Terminator II design provides a durable barrier material (TSC Compound) that maintains seal integrity over time, lowering preventive-maintenance frequency. The aluminum construction resists corrosion in saline or chemical environments, extending service life in offshore platforms or chemical plants. Together with NEC/CEC compliance and Class I, II, III ratings, this gland supports sustained regulatory alignment and audits. Industry professionals appreciate the streamlined documentation and downloadable resources such as installation instructions and specification sheets, which shorten onboarding for technicians and procurement teams. With a focus on reducing operational risk and total cost of ownership, the TMCX200 2 cable gland helps facilities meet rigorous hazardous-location standards while maintaining high availability.
Get a Quick Quote for a Eaton Crouse-Hinds TMCX200 2
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TMCX200 2?
Enquire Now
FAQs
Ensure enclosure openings are prepared for a 2 inch NPT gland and verify cable ranges in the 1.81 to 2.72 inch band. Use appropriate armour and tray cable types listed for explosion-proof glands. Follow NEC/CEC guidelines and UL or equivalent compliance documentation when retrofitting equipment into Class I, II, III environments.
The unit is designed for Hazardous/Classified Locations with NEC/CEC standards conformance and a NEMA 4X rating. It supports Class I, Division 1; Class II, Division 1; Class III hazardous ratings, ensuring robust protection in chemical plants, refineries, and mining operations.
Yes. It is compatible with armoured barrier, TECK armoured, and metal-clad cables with interlocked or continuously welded corrugated armour, as well as tray cables. The gland type is Armoured, suitable for 2" NPT threaded mounting and a sealing range of 1.81–2.72 inches, simplifying cable selection.
The explosion-proof design and durable aluminum body resist corrosion and seal degradation, reducing unplanned outages. Its robust 2M sealing range and barrier material help maintain ingress protection over time, lowering preventive maintenance frequency and extending service life in harsh environments, leading to lower total cost of ownership.
Refer to Eaton's installation sheets IF 1647B for Terminator II and the Eaton specification sheet for TMCX200 2. These documents provide mounting instructions, torque recommendations, cable ranges, and material specs to support quick, compliant field installations.