Eaton Crouse-Hinds Terminator II TMCX200 2 L Cable Gland - Explosion-Proof, NEMA 4X

Part Number: TMCX200 2 L
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
TMCX200 2 L

Quick Summary

The TMCX200 2 L cable gland is a rugged, explosion-proof seal for armored cables used in hazardous locations. Field technicians often contend with moisture ingress, mismatched seals, and downtime caused by unreliable gland performance. This terminator II gland supports NEC/CEC compliance and area classifications for hazardous/classified locations, with a NEMA 4X rating for demanding environments. Its aluminum body and TECK armoured compatibility deliver durable protection, even in corrosive or washdown areas. The design accommodates TECK armoured, metal-clad, and tray-cable configurations, simplifying installation and reducing spare-part needs. By delivering robust sealing and straightforward field assembly, it helps ensure ongoing safety, reduced leaks, and lower lifecycle costs for safety-critical facilities.

Product Information

Extended Description

TMCX200 2 L Eaton Crouse-Hinds: Eaton Crouse-Hinds series Terminator II TMCX cable gland,Liquid compound,Cable Range:1.81-2.72",Cable Sealing:2 (M),Metal-cladcorrugated armoured,TECK armoured,armoured barrier and tray cable,Armoured gland, Aluminum, 2" NPT
Product Name
Eaton Crouse-Hinds series Terminator II TMCX cable gland
Catalog Number
TMCX200 2 L
UPC
662276440296
Product Length/Depth
6.88 in
Product Height
4.98 in
Product Width
4.98 in
Product Weight
12.52 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
4X
Protection type
Explosion-proof
Cable type
TECK armoured Tray cable Metal-clad with interlocked or continuously welded corrugated armoured Armoured barrier
Gland type
Armoured
Thread Size
2"
Thread type
NPT
Cable sealing range
2 (M)
Cable range (min/max)
1.81-2.72"
Material
Aluminum
Barrier type
Liquid Compound
Feature → Explosion-proof aluminum body with armoured barrier compatibility. Business Impact → Reduces ignition risk and protects equipment in explosive atmospheres, supporting compliance in hazardous locations. Application → TECK armoured, metal-clad tray cables in petrochemical plants and offshore facilities benefit from durable, fail-safe sealing. Feature → Cable sealing range 2 (M) and range 1.81-2.72 inches. Business Impact → Ensures a precise seal across a defined set of cable diameters, preventing moisture ingress and gasket failures. Application → Sealing for 1.81–2.72 in cables in control panels, enclosures, and field joints across harsh environments. Feature → 2" NPT thread size. Business Impact → Standardized penetrations accelerate installation and stocking, reducing project lead times. Application → Fits common 2" NPT boss openings in enclosures and equipment housings. Feature → Aluminum body and liquid compound barrier. Business Impact → Corrosion resistance and effective sealing under washdowns, improving lifecycle costs. Application → Use in chemical plants, water treatment, and mining where armoured barriers are required. Feature → Area classification and NEC/CEC compliance with NEMA 4X protection. Business Impact → Ensures regulatory compliance and reliable performance in hazardous locations. Application → Suitable for Class I, II, III environments with rugged outdoor or washdown demands.

Get a Quick Quote for a Eaton Crouse-Hinds TMCX200 2 L

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds TMCX200 2 L? Enquire Now

FAQs

Install on a 2" NPT opening using the TECK armoured configuration. The gland supports TECK armoured and metal-clad tray cables with a liquid barrier and a 2 (M) sealing range for cables 1.81–2.72 inches in diameter. Refer to IF 1647 installation sheets for torque, assembly order, and gasket seating guidance.
Key specs include explosion-proof protection, NEC/CEC compliance, and a NEMA 4X rating for harsh environments. The cable sealing range is 2 (M) with a cable range of 1.81–2.72 inches, designed for TECK armoured and tray cable types. These features collectively support reliable ingress protection and regulatory compliance in hazardous locations.
Yes. It carries NEC hazardous ratings for Class I Division 1, Class II Division 1, and Class III, with area classification for Hazardous/Classified Locations and a NEMA 4X enclosure rating, making it appropriate for the most demanding hazardous-location installations.
Available materials include the Crouse-Hinds Chico LiquidSeal flyers, the TMCX II catalog page, UL Canadian certification references, IF 1647 instruction sheets, installation guides, and the Eaton specification sheet. These resources assist with selection, installation, and regulatory verification.
It reduces downtime through robust sealing, lowers maintenance costs with corrosion-resistant aluminum construction, and ensures regulatory compliance via NEC/CEC standards and NEMA 4X protection. Its compatibility with TECK armoured and metal-clad cables streamlines procurement and installation, delivering long-term lifecycle savings.