Eaton TMCX3112 BR Cable Gland - Explosion-Proof
Part Number: TMCX3112 BR
Quick Summary
The TMCX3112 BR cable gland from Eaton protects TECK armoured and tray cables in hazardous locations. Engineers and procurement teams face ongoing challenges maintaining seal integrity and safe cable entries under harsh environments and tight project schedules. This gland aligns with NEC/CEC requirements and hazardous-location ratings, including Class I, Division 1; Class II, Division 1; Class III, plus a NEMA 4 enclosure rating. Built for rugged field installations, it supports armoured barrier and non-armoured barrier configurations. The combination of robust brass casting, 1" NPT threading, and precise outer sheath and armor tolerances improves installation speed, reduces maintenance downtime, and strengthens regulatory compliance—delivering measurable cost savings over life cycles.
Product Information
Extended Description
TMCX3112 BR Eaton Crouse-Hinds: Eaton Crouse-Hinds series TMCX cable gland,Metal-cladcorrugated,TECK armoured and tray cable,Armoured barrier and non-armoured barrier, Brass, Outer Sheath:0.85-1.31", 1" NPT,Armor Range:0.80-1.12"
Product Name
Eaton Crouse-Hinds series TMCX cable gland
Catalog Number
TMCX3112 BR
UPC
782274037318
Product Length/Depth
4.07 in
Product Height
2 in
Product Width
2 in
Product Weight
1.75 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
4
Protection type
Explosion-proof
Cable type
TECK armoured Tray cable Metal-clad with interlocked or continuously welded corrugated armoured
Gland type
Armoured Barrier and Non-armoured Barrier
Material
Brass
Thread Size
1"
Thread type
NPT
Armor (min/max)
0.80-1.12"
Outer sheath (min/max)
0.85-1.31"
Crouse-Hinds series TMCX catalog page
TMCX Explosionproof Armoured Barrier Gland UL certification
IF 1184 - TMCX Terminator Cable Fittings
Eaton Specification Sheet - TMCX3112 BR
Brass construction provides robust corrosion resistance for tough industrial environments, reducing replacement costs and downtime. This durability is particularly valuable in chemical plants, refineries, offshore platforms, and mining sites where moisture, salt spray, and aggressive substances challenge seal performance and cable integrity. By selecting a gland designed for explosion-proof service, maintenance teams benefit from longer service intervals, fewer leak-related failures, and improved overall asset reliability, translating to lower total cost of ownership across the lifecycle of installations. With a 1 inch NPT thread, installation is straightforward alongside common conduit systems, minimizing field assembly time and risk of leaks. It is engineered for TECK armoured tray cables and metal-clad with interlocked or welded armour, ensuring a secure seal even in vibratory, high-temperature, and demanding heavy-industrial environments. The standardized thread also simplifies spares management, allowing technicians to reuse compatible fittings across multiple projects. Armoured Barrier and Non-armoured Barrier options provide flexible configurations without changing fittings, speeding retrofits and new installations. This versatility reduces procurement complexity and helps projects adapt to evolving cable assemblies while maintaining the same enclosure protection level and regulatory compliance. For installers, this translates into fewer part substitutions, shorter lead times, and a more predictable commissioning sequence. Armor range 0.80–1.12 in and outer sheath 0.85–1.31 in provide a precise fit for TECK armoured trays, preventing looseness that can compromise protection. Combined with a brass body and 1" NPT threading, this gland delivers reliable ingress protection (NEMA 4) and durability in harsh environments. Long-term performance is supported by UL explosion-proof listing and NEC/CEC conformity, reducing risk in critical safety applications. UL certification and NEC/CEC compliance streamline regulatory approvals, while the gland’s rugged construction supports continuous operation in Class I, Division 1, Class II, Division 1, and Class III environments across chemical processing, oil & gas, mining, and power generation sectors. Catalog availability and compatibility with Eaton's installation sheets streamline procurement, training, and on-site installation, reducing project delays and warranty issues. In practice, these factors translate to faster time to productive operation and measurable ROI on new and retrofit projects.
Get a Quick Quote for a Eaton Crouse-Hinds TMCX3112 BR
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TMCX3112 BR?
Enquire Now
FAQs
Designed for hazardous/classified locations per NEC/CEC, including Class I, Division 1, Class II, Division 1, and Class III, with NEMA 4 protection and UL explosion-proof listing suitable for chemical, oil & gas, and mining environments.
Yes. The gland supports TECK armoured tray cables with interlocked or welded armour and offers armoured barrier and non-armoured barrier configurations for flexible installations.
It features a 1 inch NPT thread with brass construction. Armor range is 0.80–1.12 inches and outer sheath range is 0.85–1.31 inches. Overall size is 4.07 in length, 2 in width, and 2 in height.
NEC/CEC compliance, UL exploded-proof certification, and NEMA 4 enclosure rating, supporting Class I, II, III hazardous locations with robust field reliability.
Improved safety and regulatory compliance, reduced maintenance and downtime, faster installation with 1" NPT threading, and flexible barrier configurations that simplify procurement and retrofit efforts.