Eaton Crouse-Hinds TMCX350 1 NP CableGland - Explosionproof

Part Number: TMCX350 1 NP
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
TMCX350 1 NP

Quick Summary

The TMCX350 1 NP cable gland delivers explosion-proof sealing for armoured cables in hazardous locations, enabling safe, long-term operation. Engineers face retrofit challenges in tight enclosures, where improper glands can cause seal leaks, corrosion, or misalignment that disrupts control loops. This product integrates with TSC compound barriers and multiple armour configurations, offering robust protection across TECK, metal-clad, and corrugated armour systems. It carries Hazardous/Classified Locations approvals, NEC/CEC compliance, and a NEMA 4X rating, aligning with global electrical codes and safety standards. For procurement teams, the Terminator II family reduces installation time, simplifies inventory with a single gland range, and supports compliance-driven cost control.

Product Information

Extended Description

TMCX350 1 NP Eaton Crouse-Hinds: Eaton Crouse-Hinds series Terminator II TMCX cable gland,TSC compound,Cable Range:2.62-3.78",Cable Sealing:1 (S),Metal-cladcorrugated armoured,TECK armoured,armoured barrier and tray cable,Armoured gland, Nickel-plated brass, 3-1/2" NPT
Product Name
Eaton Crouse-Hinds series Terminator II TMCX cable gland
Catalog Number
TMCX350 1 NP
UPC
662276442566
Product Length/Depth
8.2 in
Product Height
6.23 in
Product Width
6.23 in
Product Weight
39.72 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
4X
Protection type
Explosion-proof
Cable type
Armoured barrier Tray cable Metal-clad with interlocked or continuously welded corrugated armoured TECK armoured
Gland type
Armoured
Thread Size
3-1/2"
Thread type
NPT
Cable sealing range
1 (S)
Cable range (min/max)
2.62-3.78"
Material
Nickel plated brass
Barrier type
TSC Compound
Explosion-proof protection is the core capability, delivering a robust seal for armoured cables while meeting NEC/CEC requirements and hazardous-location classifications. The business impact is clear: reduced risk of arcing, containment breaches, and costly downtime in refineries and chemical plants. In practice, this means safer panel entries and more predictable maintenance cycles for critical control circuits. Armoured barrier and TECK compatibility extend installation options. The gland supports metal-clad, interlocked or welded corrugated armour, and tray cables, which reduces the need for adapters and rework. Operators gain flexibility during panel builds and field retrofits, speeding commissioning and cutting inventory complexity while staying compliant with global armoured cable standards. Precise mechanical specs enable reliable sealing. With a 3-1/2 inch NPT thread, nickel-plated brass construction, and a sealing range of 2.62–3.78 inches, the gland tolerates real-world cable dimensional variation. The 1 (S) sealing mechanism simplifies field sealing while providing durable ingress protection in rugged environments. Environmental and regulatory robustness. Rated for Hazardous/Classified Locations and conforming to NEMA 4X, the gland resists dust, water, and corrosion, supporting outdoor and wet installations. This translates to lower replacement frequency, lower maintenance costs, and better total cost of ownership for long-life installations. Ease of installation and design support. The Terminator II family is designed for panel builders and integrators, with ready access to CAD drawings, instruction sheets, and spec sheets that accelerate engineering and reduce risk during commissioning. By standardizing on this gland, teams can improve procurement lead times and ensure traceable compliance throughout the project lifecycle.

Get a Quick Quote for a Eaton Crouse-Hinds TMCX350 1 NP

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds TMCX350 1 NP? Enquire Now

FAQs

When installing the TMCX350 1 NP in hazardous locations, ensure the enclosure has appropriate ingress protection and that mounting surfaces are clean and corrosion-free to maintain gasket integrity. Use the 3-1/2 inch NPT thread to accept standard gland fittings, verify the 2.62–3.78 inch cable range matches your armoured or TECK armoured cables, and follow the supplied IF1647B instructions for correct sealing and barrier deployment.
The specified cable sealing range of 2.62–3.78 inches accommodates typical armoured cables used in hazardous areas, reducing the need for adapters and field modification. Properly matching the cable diameter to the sealing range ensures reliable ingress protection, minimizes leaks, and maintains the gland’s explosion-proof integrity under dynamic temperature and vibration conditions common in industrial environments.
Yes. The TMCX350 1 NP supports TECK armoured, armoured barrier, and metal-clad cables, including interlocked or welded corrugated armour. This versatility simplifies panel design and retrofits in chemical plants, refineries, and mining operations, enabling a single gland solution across multiple cable architectures while preserving compliance with applicable standards.
The gland is approved for Hazardous/Classified Locations and NEC/CEC compliant, with a NEMA 4X rating. These certifications ensure suitability for Class I, Division 1 environments as well as Class II and III, supporting safety and regulatory requirements across North American and international facilities.
Terminator II glands offer predictable performance, reducing maintenance cycles due to robust sealing and corrosion resistance of nickel-plated brass. By standardizing on a single gland range, procurement leads are shortened, field downtime is minimized, and lifecycle costs drop as spares inventory and commissioning time are streamlined.