Eaton Crouse-Hinds TMCXM25 2 NP L Cable Gland - Explosion-proof

Part Number: TMCXM25 2 NP L
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
TMCXM25 2 NP L

Quick Summary

Eaton Crouse-Hinds Terminator II TMCX cable gland is a high‑integrity sealing solution for armored and non‑armored cables in hazardous locations. In practice, selecting the right gland reduces moisture ingress, arc risk, and unplanned downtime caused by incorrect termination. This model aligns with NEC/CEC compliance and rugged NEMA 4X/6P reliability, supporting safe installations in demanding environments. With an M25 thread and armor-compatible construction, it also delivers operational efficiency and predictable maintenance costs for industrial automation and process control projects.

Product Information

Extended Description

TMCXM25 2 NP L Eaton Crouse-Hinds: Eaton Crouse-Hinds series Terminator II TMCX cable gland,Liquid compound,Cable Range:16.5-29.9 mm,Cable Sealing:2 (M),Metal-cladcorrugated armoured,TECK armoured,armoured barrier and tray cable,Armoured gland, Nickel-plated brass, M25
Product Name
Eaton Crouse-Hinds series Terminator II TMCX cable gland
Catalog Number
TMCXM25 2 NP L
UPC
662276304208
Product Length/Depth
4.18 in
Product Height
2.25 in
Product Width
2.25 in
Product Weight
2.3 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
4X 6P
Protection type
Explosion-proof
Cable type
Armoured barrier Metal-clad with interlocked or continuously welded corrugated armoured TECK armoured Tray cable
Gland type
Armoured
Thread Size
M25
Thread type
Metric
Cable sealing range
2 (M)
Cable range (min/max)
16.5-29.9 mm
Material
Nickel plated brass
Barrier type
Liquid Compound
Feature: Armor‑grade construction using nickel-plated brass ensures corrosion resistance in harsh environments → Business Impact: longer service life and fewer gland replacements, reducing maintenance costs over the asset’s life → Application: oil & gas, chemical plants, and hazardous locations where corrosion risk is high. Feature: Cable sealing range of 2 (M) and cable range of 16.5–29.9 mm → Business Impact: accommodates a wide variety of cables without custom adapters, lowering stocking needs and installation time → Application: mixed cabling in control panels and field junctions. Feature: Thread Size M25 (Metric) and Armoured Gland type → Business Impact: simplifies compatibility with standard enclosures and fast, reliable sealing → Application: panel entries and outdoor housings requiring standard metric glands. Feature: Protection type Explosion-proof and Area classification Hazardous/Classified Locations → Business Impact: ensures compliant performance in Class I, II, III environments, reducing regulatory risk → Application: petrochemical, mining, and heavy manufacturing where hazardous atmospheres exist. Feature: Barrier type Liquid Compound and Cable type compatibility (armoured, TECK, tray cable) → Business Impact: versatile sealing for multiple installation configurations, improving project flexibility and inventory control → Application: armored barrier glands on complex cable runs in both new builds and retrofits. Feature: NEMA Rating 4X 6P and NEC/CEC standards compliance → Business Impact: proven enclosure protection and regulatory adherence, improving uptime and insurance positioning → Application: outdoor, dusty, and wet environments where robust protection is required.

Get a Quick Quote for a Eaton Crouse-Hinds TMCXM25 2 NP L

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds TMCXM25 2 NP L? Enquire Now

FAQs

For proper installation, use the M25 metric thread to secure the gland into standard enclosures. Ensure the cable range is within 16.5-29.9 mm and that the cable sealing range is 2 (M) to achieve a reliable seal. Compatible with armored, TECK, and tray cables, the gland should be mounted in a controlled environment to maintain NEMA 4X/6P protection.
The TMCXM25 2 NP L is designed for Hazardous/Classified Locations with NEC/CEC compliance and NEC hazardous ratings that include Class I, Division 1; Class II, Division 1; and Class III. It also carries a NEMA rating of 4X 6P, enabling safe operation in tough industrial environments and helping you satisfy regulatory and insurance requirements.
Yes. The gland supports armoured barrier and metal-clad cables with interlocked or continuously welded corrugated armour, TECK armour, and tray cables. This broad compatibility reduces part variety and simplifies implementation for mixed cabling in control rooms, switchgear, and field installations.
The gland uses nickel-plated brass for corrosion resistance, combined with a liquid compound barrier for robust sealing. These features minimize ingress under moisture and chemical exposure, extending service life and reducing maintenance cycles in harsh industrial settings.
By delivering reliable ingress protection, NEC/CEC compliance, and reduced maintenance due to corrosion resistance and wide cable compatibility, operators can lower downtime, prevent non-conformance penalties, and optimize spares inventory. Over asset life, the gland contributes to a lower total cost of ownership in demanding environments.