Eaton Crouse-Hinds VMVL-17-UNV1-S891-M2 LED Light - IP66
Part Number: VMVL-17-UNV1-S891-M2
Manufacturer
Eaton Crouse-Hinds
Part number
VMVL-17-UNV1-S891-M2
Category
Quick Summary
The VMVL-17-UNV1-S891-M2 LED light fixture from Eaton Crouse-Hinds delivers high-output illumination for hazardous-area facilities. In harsh environments, engineers often struggle with reliable performance and maintaining regulatory compliance over time. It meets IECEx/ATEX Zone 21, NEC Class I, Division 2, and IP66/NEMA 4X, ensuring rugged durability in demanding locations. Designed for flexible mounting and energy-efficient operation, it reduces maintenance costs while delivering consistent lighting performance for critical processes and safety compliance.
Product Information
Extended Description
VMVL-17-UNV1-S891-M2 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Champ VMVL LED fixture, Cool white, 400W-600W HID equivalent, No guard, Diffused glass lens, 17000 lumens, 121 lm/W, Die cast aluminum, No mounting module, Type V, 120-277 Vac, 108-250 Vdc, 140W
Product Name
Eaton Crouse-Hinds series Champ VMVL LED light fixture
Catalog Number
VMVL-17-UNV1-S891-M2
UPC
662276992313
Product Length/Depth
14.17 in
Product Height
9.53 in
Product Width
14.17 in
Product Weight
22.3 lb
Area classification
Hazardous/Classified Locations
Standards type
IEC NEC/CEC IECEx/ATEX
NEC hazardous rating
Class III Class I, Division 2 Class I, Zone 2 Class II, Division 1
IECEx/ATEX hazardous rating
Zone 21
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Lumens
17000
Lumens per watt
121
Color temperature
Cool white
Mounting Method
No mounting module
Optical distribution
Type V
Guard type
No guard
Voltage rating
120-277 Vac, 108-250 Vdc
Frequency rating
50/60 Hz
Wattage
140W
Dimming
Dimmable driver
Power factor
> 0.90
Equivalent luminaire
400W-600W HID
Material
Die cast aluminum
Lens material
Diffused Glass
SP3D Design Package - Champ VMVL LED Hazardous Area Light Fixtures
Crouse-Hinds series DLC approved lighting products
Crouse-Hinds series DLC approved lighting products
Crouse-Hinds series DLC approved lighting products
Crouse-Hinds series Champ VMVL LED Luminaires - 17,000 to 25,000 lumens catalog pages
IF 1882 - Champ VMVL and PVML LED luminaires
IF 1882 - Champ VMVL and PVML LED luminaires
IF 1882 - Champ VMVL and PVML LED luminaires
Crouse-Hinds series Champ VMVL LED High Lumen IES photometric files
Crouse-Hinds series Champ VMVL LED High Lumen IES photometric files
Crouse-Hinds series Champ VMVL LED High Lumen IES photometric files
Feature → Business Impact → Application: 17000 lumen cool-white LED output with a 121 lm/W efficiency reduces fixture counts and lowers energy consumption in long-run hazardous-location installations such as chemical plants and oil refineries. This translates to lower operating costs and fewer outages in mission-critical areas. Application: Ideal for Class I, Division 2 environments demanding reliable illumination with long service life. Feature → Business Impact → Application: Diffused glass lens and die-cast aluminum housing provide robust protection against dust, moisture, and impacts, extending fixture life in rugged facilities. Application: Perfect for wet, dusty, or explosive-hazard zones where continuous operation is essential. Feature → Business Impact → Application: Dimmable driver and wide voltage range (120-277 Vac, 108-250 Vdc) enable seamless integration with existing controls and power systems, reducing installation time. Application: Suitable for retrofits and new builds in hazardous locations requiring flexible dimming and drive efficiency. Feature → Business Impact → Application: Type V optical distribution with no mounting module simplifies installation and alignment, decreasing commissioning time by engineers onsite. Application: Use in large-area luminaires for warehouse, plant floor, and maintenance aisles. Feature → Business Impact → Application: IP66, NEMA 4X protection and Zone 21/Zone-rated compliance provide end-to-end safety, lowering regulatory risk and documentation effort. Application: Essential for facilities handling dust, water ingress, or corrosive environments where robust sealing matters.
Get a Quick Quote for a Eaton Crouse-Hinds VMVL-17-UNV1-S891-M2
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds VMVL-17-UNV1-S891-M2?
Enquire Now
FAQs
For hazardous locations, follow local compliance codes and ensure a secure mounting method since this unit is designed for Zone 21 and Class I/Division 2 environments. Use proper conduit fittings, sealants, and anti-rotation mounting hardware. The fixture’s no mounting module means you may require compatible brackets or housings to achieve the correct orientation and spacing on industrial ceilings or walls.
The luminaire produces 17000 lumens at 140W with a 121 lm/W efficacy and PF > 0.90, replacing 400W–600W HID equivalents. This results in meaningful energy savings, reduced maintenance cycles due to longer LED life, and lower total-cost-of-ownership in continuous-operation settings like processing floors and loading docks.
Yes. The fixture is rated NEC Class I Division 2 and Zone 21 per IECEx/ATEX, along with IP66 and NEMA 4X protections. This combination supports operation in hazardous areas with chemical exposure, dust, and moisture, while complying with industry electrical codes and safety standards.
The VMVL-17-UNV1-S891-M2 supports 120-277 VAC and 108-250 VDC with a dimmable driver, enabling flexible integration with emergency and general lighting controls. The wide voltage range reduces the need for power conversion during retrofits, while dimming helps optimize energy use and light levels for different shifts or tasks.
Expect considerations around mounting, sealing, and alignment in hazardous spaces. The unit uses a diffused glass lens and die-cast aluminum housing for durability, with no integrated mounting module which simplifies certain configurations but may require compatible brackets. Planning for IP66/NEMA 4X protection and Zone 21 compliance during initial installation reduces rework and guarantees long-term reliability.