Eaton Crouse-Hinds VMVL-3-P-R1-UNV1-S903 LED - HazLoc IP66
Part Number: VMVL-3-P-R1-UNV1-S903
Manufacturer
Eaton Crouse-Hinds
Part number
VMVL-3-P-R1-UNV1-S903
Category
Quick Summary
Eaton Crouse-Hinds VMVL LED light fixture provides rugged illumination for hazardous area applications in industrial facilities. Engineers often battle lighting that fails in demanding environments, leading to maintenance delays and safety risks. This luminaire carries NEC/CEC IECEx/ATEX certifications, IP66 ingress protection, and a NEMA 4X rating, supporting Zone 2 and Class I Division 2 classifications. With a dimmable driver, wide voltage range, and a die-cast aluminum housing, it delivers reliable operation and lower lifecycle costs for asset-intensive plants. The rugged design is also well-suited for hazardous-location lighting, making it an ideal solution for industrial lighting needs, including LED luminaires and hazardous area luminaire applications.
Product Information
Extended Description
VMVL-3-P-R1-UNV1-S903 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Champ VMVL LED fixture, Cool white, 70W HID equivalent, No guard, Polycarbonate lens, 3000 lumens, 123 lm/W, Die cast aluminum, Stanchion straight, Type I, 1-1/2" trade size, 100-277 Vac, 127-250 Vdc, 28W
Product Name
Eaton Crouse-Hinds series Champ VMVL LED light fixture
Catalog Number
VMVL-3-P-R1-UNV1-S903
UPC
662276887169
Product Length/Depth
16.03 in
Product Height
11.1 in
Product Width
11.62 in
Product Weight
23.5 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IEC IECEx/ATEX
NEC hazardous rating
Class I, Division 2 Class I, Zone 2 Class II, Division 1 Class III
IECEx/ATEX hazardous rating
Zone 21
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Lumens
3000
Lumens per watt
123
Color temperature
Cool white
Mounting Method
Stanchion straight
Trade size
1-1/2"
Optical distribution
Type I
Guard type
No guard
Voltage rating
100-277 Vac, 127-250 Vdc
Frequency rating
50/60 Hz
Wattage
28W
Dimming
Dimmable driver
Power factor
> 0.90
Equivalent luminaire
70W HID
Material
Die cast aluminum
Lens material
Polycarbonate
SP3D Design Package - Champ VMVL LED Hazardous Area Light Fixtures
Crouse-Hinds series Champ VMVL LED Luminaires - 3,000 to 13,000 lumens brochure
Crouse-Hinds series Champ VMVL LED Luminaires - 3,000 to 13,000 lumens brochure
Crouse-Hinds series Champ VMVL LED Luminaires - 3,000 to 13,000 lumens brochure
Crouse-Hinds series Champ VMVL LED luminaires - 3,000 to 13,000 lumens catalog page
IF 1888 - Champ VMVL and PVML Driver Replacement
IF 1888 - Champ VMVL and PVML Driver Replacement
Champ VMV LED Hazardous Area
Champ VMV LED Hazardous Area
Feature: Die cast aluminum housing with a polycarbonate lens provides exceptional corrosion resistance and impact protection. Business impact: minimizes maintenance costs and downtime in harsh environments, extending service life in chemical plants and offshore facilities. Application: suitable for washdown zones and outdoor installations where harsh chemicals or salt spray are present. Feature: IP66 ingress protection and NEMA 4X enclosure rating for robust environmental sealing. Business impact: protects critical lighting from dust, water jets, and washdowns, reducing replacement cycles and ensuring consistent illumination. Application: marine, chemical processing, and rugged outdoor locations. Feature: Type I optical distribution delivers predictable, focused illumination along stanchion-mounted runs. Business impact: improves safety and workflow by reducing shadowed areas and optimizing workspace visibility. Application: utility corridors, loading bays, and process lines. Feature: 28W power with 3000 lumens and 123 lm/W efficacy. Business impact: HID-equivalent performance with significantly reduced energy use and heat generation. Application: facilities aiming to lower energy bills and cooling loads. Feature: Wide voltage range 100-277 Vac and 127-250 Vdc with a dimmable driver. Business impact: simplifies stocking for global facilities and enables on-demand lighting control, improving energy management. Application: multi-site plants and hazardous-area installations requiring dimming capability. Feature: Stanchion straight mounting and 1-1/2 inch trade size for quick, compatible installation. Business impact: reduces labor time and retrofit costs, enabling faster deployment in existing infrastructure. Application: plant walkways, platforms, and elevated work areas with standard stanchions.
Get a Quick Quote for a Eaton Crouse-Hinds VMVL-3-P-R1-UNV1-S903
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds VMVL-3-P-R1-UNV1-S903?
Enquire Now
FAQs
Yes. The VMVL fixture meets NEC/CEC and IECEx/ATEX certifications, includes Zone 2 and Class I Division 2 ratings, and features IP66 and NEMA 4X protection. This combination supports safe operation in hazardous locations while delivering reliable LED illumination in demanding processing areas.
The unit uses a straight stanchion mounting with a 1-1/2 inch trade size, aligning with standard industrial supports. This simplifies integration into existing walkways, platforms, and process lines, reducing field modification time and enabling faster commissioning.
Operating voltage is 100-277 Vac and 127-250 Vdc at 50/60 Hz, with a dimmable driver and a power draw of 28W. The fixture delivers a high power factor (>0.90) and 3000 lumens at 123 lm/W, making it suitable for energy management programs and controlled illumination in hazardous settings.
Certifications include NEC/CEC and IECEx/ATEX, with hazardous location ratings such as Zone 2 and Class I Division 2, plus Zone 21 for IECEx/ATEX. The luminaire also carries IP66 ingress protection and a NEMA 4X enclosure rating, ensuring robust compliance for industrial environments.
The VMVL LED solution consumes 28W for around 3000 lumens, delivering energy savings vs 70W HID equivalents while reducing ballast and lamp maintenance. Its long service life, dimmable driver, and rugged construction lower lifecycle costs, minimize downtime, and improve plant reliability in asset-intensive facilities.