Eaton Crouse-Hinds VMVL-5-UNV1-EM1 LED Light - IP66
Part Number: VMVL-5-UNV1-EM1
Quick Summary
VMVL-5-UNV1-EM1 LED light fixture with emergency back-up is designed to deliver dependable illumination for hazardous industrial environments. In demanding facilities, outages or power quality issues can compromise safety, so this fixture provides reliable emergency illumination to keep egress paths and critical work areas illuminated. It carries IP66 and NEMA 4X ratings, along with NEC/CEC compliance and hazardous-location classifications such as Class I Division 2, Zone 2, Class II Division 1, and Class III, ensuring suitability in a wide range of locations. With 5000 lumens at 128 lm/W and a universal 100-277 VAC input, it combines energy efficiency with robust performance. The result is safer operations, simplified procurement, and a scalable lighting solution that supports modern control strategies and lifecycle cost reduction.
Product Information
Extended Description
VMVL-5-UNV1-EM1 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Champ VMVL LED light fixture with emergency back-up, Cool white, 0-10V dimming, No guard, Tempered glass lens, 5000 lumens, 128 lm/W, Copper-free aluminum, No mounting module, Type V, 100-277 Vac, 46W
Product Name
Eaton Crouse-Hinds series Champ VMVL LED light fixture with emergency back-up
Catalog Number
VMVL-5-UNV1-EM1
UPC
662276957756
Product Length/Depth
13.13 in
Product Height
15.68 in
Product Width
12.75 in
Product Weight
32.7 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2 Class I, Zone 2 Class II, Division 1 Class III
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Lumens
5000
Lumens per watt
128
Color temperature
Cool white
Mounting Method
No mounting module
Optical distribution
Type V
Guard type
No guard
Voltage rating
100-277 Vac
Material
Cast copper-free aluminum
Lens material
Tempered glass
Special features
Emergency driver system
Dimming
0-10 V
Frequency rating
50/60 Hz
Power factor
> 0.90
Wattage
46W
SP3D Design Package - Champ VMVL EM with Emergency Back-up Battery
Champ VMVL LED with Emergency Back-up Battery flyer
Crouse-Hinds series Champ VMVL LED with Emergency Back-up catalog page
IF 1920 - Champ VMVL and PVML Emergency LED Battery and Driver Replacement Kit
IF 1920 - Champ VMVL and PVML Emergency LED Battery and Driver Replacement Kit
Eaton Specification Sheet - VMVL-5-UNV1-EM1
Feature: 5000 lumens at 128 lm/W with a 46W input. Business Impact: high brightness and efficiency reduce energy usage and cooling needs while delivering strong visibility across large areas. Application: plant floors, storage halls, and maintenance corridors in hazardous locations. Feature: Universal voltage 100-277 VAC. Business Impact: simplifies electrical design, lowers inventory costs, and enables quick retrofits without rewiring. Application: installations with mixed voltage sources or evolving power systems in industrial facilities. Feature: Emergency back-up / emergency driver system. Business Impact: maintains essential illumination during power outages, supporting safe evacuation and compliance with safety standards. Application: egress routes, exit stairwells, and safety-critical zones in hazardous environments. Feature: Rugged enclosure with copper-free aluminum, tempered glass lens, IP66 and NEMA 4X. Business Impact: superior corrosion and impact resistance reduces maintenance cycles and downtime. Application: harsh, wet, dirty, or chemically aggressive spaces such as chemical plants or offshore facilities. Feature: Type V optical distribution with no guard and no mounting module. Business Impact: optimized light spread and easier install/removal, lowering installation time and cost. Application: high-height ceilings and open-area lighting in industrial settings. Feature: 0-10V dimming and 50/60 Hz compatibility. Business Impact: enables integration with building and process controls for energy savings and better visibility control. Application: sensor-based or occupancy-controlled hazardous-area lighting schemes for continuous uptime while saving energy.
Get a Quick Quote for a Eaton Crouse-Hinds VMVL-5-UNV1-EM1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds VMVL-5-UNV1-EM1?
Enquire Now
FAQs
VMVL-5-UNV1-EM1 is qualified for Class I Division 2, Zone 2, Class II Division 1, and Class III configurations, with NEC/CEC compliance. Its IP66/NEMA 4X enclosure and lack of a mounting module simplify retrofits and align with stringent safety standards in chemical plants, refineries, and mining sites.
The fixture accepts 100-277 VAC, uses 46W to deliver 5000 lumens at 128 lm/W, and supports 50/60 Hz. It also includes 0-10V dimming for control integration, enabling compatible occupancy or process-control schemes in hazardous environments.
The unit includes an emergency driver system that provides backup illumination during power interruptions. This supports safe egress and operations in critical zones without requiring separate standby gear, which simplifies maintenance and increases reliability.
Key certifications include NEC/CEC compliance, IP66 ingress protection, NEMA 4X enclosure rating, and hazardous-location classifications such as Class I Division 2, Zone 2, Class II Division 1, and Class III, making it suitable for a wide range of industrial and hazardous settings.
Product dimensions are 13.13 in L, 15.68 in H, and 12.75 in W with a weight of 32.7 lb, enabling accurate space planning and mounting considerations in ceilings or protected enclosures.