Eaton Crouse-Hinds VMVL-5-W-J-UNV1-TB6 LED light fixture - IP66
Part Number: VMVL-5-W-J-UNV1-TB6
Manufacturer
Eaton Crouse-Hinds
Part number
VMVL-5-W-J-UNV1-TB6
Category
Quick Summary
The VMVL LED light fixture from Eaton Crouse-Hinds provides reliable hazardous-location illumination for industrial facilities. Many engineers struggle with rugged environments, broad voltage needs, and the risk of noncompliant fixtures in hazardous areas. This luminaire carries NEMA 4X, IP66, and IECEx/ATEX Zone 21 certifications, with NEC/CEC compliance for Class I, Division 2 and other hazardous locations. Designed for energy-efficient upgrades, it pairs universal voltage operation with dimmable drivers for reliable, low-maintenance lighting in industrial plants.
Product Information
Extended Description
VMVL-5-W-J-UNV1-TB6 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Champ VMVL LED fixture, Warm white, 100W HID equiv, No guard, Glass lens, 5000 lumens, 127 lm/W, Die cast alum, Stanchion 25° angled, Type V, 6-pole terminal block, 1-1/2" trade size, 100-277 Vac, 127-250 Vdc, 45W
Product Name
Eaton Crouse-Hinds series Champ VMVL LED light fixture
Catalog Number
VMVL-5-W-J-UNV1-TB6
UPC
662276906402
Product Length/Depth
15.07 in
Product Height
12.85 in
Product Width
11.62 in
Product Weight
22.5 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IEC IECEx/ATEX
NEC hazardous rating
Class I, Division 2 Class I, Zone 2 Class II, Division 1 Class III
IECEx/ATEX hazardous rating
Zone 21
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Lumens
5000
Lumens per watt
127
Color temperature
Warm white
Mounting Method
Stanchion 25° angled
Trade size
1-1/2"
Optical distribution
Type V
Guard type
No guard
Voltage rating
100-277 Vac, 127-250 Vdc
Frequency rating
50/60 Hz
Wattage
45W
Dimming
Dimmable driver
Power factor
> 0.90
Equivalent luminaire
100W HID
Material
Die cast aluminum
Lens material
Heat and impact resistant glass
Special features
Six-pole terminal block
SP3D Design Package - Champ VMVL LED Hazardous Area Light Fixtures
Crouse-Hinds series DLC approved lighting products
Crouse-Hinds series DLC approved lighting products
Crouse-Hinds series DLC approved lighting products
Crouse-Hinds series Champ VMVL LED luminaires - 3,000 to 13,000 lumens catalog page
IF 1882 - Champ VMVL and PVML LED luminaires
IF 1882 - Champ VMVL and PVML LED luminaires
Eaton Specification Sheet - VMVL-5-W-J-UNV1-TB6
Eaton Specification Sheet - VMVL-5-W-J-UNV1-TB6
Die-cast aluminum housing and heat-resistant glass lens deliver a rugged, corrosion-resistant enclosure that withstands harsh industrial environments, reducing maintenance cycles and replacement costs while preserving light quality in demanding locations. Business impact: lower total cost of ownership and improved uptime in temperature-variant plants; Application: outdoor yards, chemical plants, and mining sites requiring durable IP66/NEMA 4X protection. Universal voltage with a dimmable driver simplifies installation and enables precise lighting control across 100-277 VAC or 127-250 VDC systems. Business impact: faster commissioning and energy savings through dimming strategies; Application: process areas where light levels must adapt to shifts or automation milestones. Type V optical distribution paired with a 5000 lumen output and 127 lm/W efficiency delivers uniform illumination over large work zones, reducing dark spots and improving sight lines for operators. Business impact: enhanced safety and productivity; Application: high-ceiling facilities and wide aisles. Six-pole terminal block and 1-1/2 inch trade size streamline wiring and field installation, minimizing downtime during retrofits. Business impact: faster project turns and reduced labor costs; Application: retrofits in hazardous locations with limited space. Dimming, warm-white output, and a robust 45W driver balance brightness with energy efficiency, while IECEx/ATEX Zone 21, IP66, and NEMA 4X ratings ensure compliance and long life. Business impact: regulatory alignment and reliable operation in chemical, oil, and gas environments; Application: hazardous-area lighting upgrades across industries.
Get a Quick Quote for a Eaton Crouse-Hinds VMVL-5-W-J-UNV1-TB6
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds VMVL-5-W-J-UNV1-TB6?
Enquire Now
FAQs
The VMVL-5-W-J-UNV1-TB6 is designed for field installation with a 1-1/2 inch trade size and a stanchion mounting option set at 25 degrees. It features a six-pole terminal block for secure connections and a sturdy die-cast aluminum housing with a glass lens. For retrofit projects, the fixture supports quick wiring and compliant wiring methods in Class I, Division 2 environments.
VMVL-5-W-J-UNV1-TB6 delivers IP66 ingress protection and NEMA 4X enclosure protection, ensuring resistance to dust, water jets, and corrosion. IECEx/ATEX Zone 21 certification confirms suitability for indoor and outdoor hazardous locations. NEC/CEC compliance with Class I, Division 2 and related zones further validates safe operation in hazardous-area facilities across oil, gas, and chemical sectors.
Yes. VMVL-5-W-J-UNV1-TB6 supports universal input of 100-277 VAC and 127-250 VDC, simplifying global or multi-site installations. It includes a dimmable driver to support adaptive lighting strategies, enabling energy savings, smoother transitions, and better operator comfort without compromising compliance in hazardous environments.
The VMVL delivers about 5000 lumens at 45W with a high efficiency of 127 lm/W, reducing energy consumption versus 100W HID equivalents. Its long-life LEDs and rugged housing lower maintenance, battery of spare parts, and scheduled relamping costs, while IP66/NEMA 4X protection minimizes downtime in wet, dusty, or corrosive locations.
Access CAD-friendly resources including SP3D Design Packages, installation sheets (IF 1882 variants), product brochures, catalog pages, and the Eaton Specification Sheet. These assets support planning, 3D modeling, wiring diagrams, and compliant installation in hazardous locations, ensuring a smooth procurement-to-installation workflow.