Eaton Crouse-Hinds VMVL-7-J-R3-UNV1-TB6 LED Fixture - IP66
Part Number: VMVL-7-J-R3-UNV1-TB6
Manufacturer
Eaton Crouse-Hinds
Part number
VMVL-7-J-R3-UNV1-TB6
Category
Quick Summary
The VMVL-7-J-R3-UNV1-TB6 LED fixture provides high-efficiency lighting for hazardous-area industrial applications. Engineers frequently confront limited mounting options, extended downtime, and strict compliance requirements in demanding environments. It carries NEC/CEC and IECEx/ATEX certifications, including Class I, Division 2 and Zone 2, with IP66 ingress protection and NEMA 4X enclosure ratings. Designed for versatile voltage input (100-277 Vac and 127-250 Vdc) and dimmable operation, the unit supports easy installation, reliable hazardous-location lighting, and lower lifecycle costs.
Product Information
Extended Description
VMVL-7-J-R3-UNV1-TB6 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Champ VMVL LED fixture, Cool white, 175W HID equiv, No guard, Glass lens, 7000 lumens, 127 lm/W, Die cast alum, Stanchion 25° angled, Type III, 6-pole terminal blk, 1-1/2" trade size, 100-277 Vac, 127-250 Vdc, 61W
Product Name
Eaton Crouse-Hinds series Champ VMVL LED light fixture
Catalog Number
VMVL-7-J-R3-UNV1-TB6
UPC
662276892736
Product Length/Depth
15.07 in
Product Height
12.85 in
Product Width
11.62 in
Product Weight
22.5 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IEC IECEx/ATEX
NEC hazardous rating
Class I, Division 2 Class I, Zone 2 Class II, Division 1 Class III
IECEx/ATEX hazardous rating
Zone 21
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Lumens
7000
Lumens per watt
127
Color temperature
Cool white
Mounting Method
Stanchion 25° angled
Trade size
1-1/2"
Optical distribution
Type III
Guard type
No guard
Voltage rating
100-277 Vac, 127-250 Vdc
Frequency rating
50/60 Hz
Wattage
61W
Dimming
Dimmable driver
Power factor
> 0.90
Equivalent luminaire
175W HID
Material
Die cast aluminum
Lens material
Heat and impact resistant glass
Special features
Six-pole terminal block
SP3D Design Package - Champ VMVL LED Hazardous Area Light Fixtures
Crouse-Hinds series Champ VMVL LED Luminaires - 3,000 to 13,000 lumens brochure
Crouse-Hinds series Champ VMVL LED Luminaires - 3,000 to 13,000 lumens brochure
Crouse-Hinds series Champ VMVL LED Luminaires - 3,000 to 13,000 lumens brochure
Crouse-Hinds series Champ VMVL LED luminaires - 3,000 to 13,000 lumens catalog page
IF 1882 - Champ VMVL and PVML LED luminaires
IF 1882 - Champ VMVL and PVML LED luminaires
Eaton Specification Sheet - VMVL-7-J-R3-UNV1-TB6
Eaton Specification Sheet - VMVL-7-J-R3-UNV1-TB6
Lumens and efficiency: The VMVL delivers 7000 lumens at 127 lm/W to maximize site visibility while reducing fixture counts. Business impact: lowers energy consumption and capital expenditure for large installations. Application: ideal for wide-area illumination in hazardous locations with Type III distribution. Rugged construction and protection: Die-cast aluminum housing with heat-dissipating design and a heat- and impact-resistant glass lens, paired with IP66 and NEMA 4X ratings. Business impact: superior durability in washdown environments and corrosive settings, lowering maintenance and replacement costs. Application: chemical plants, refineries, and outdoor yard lighting. Mounting and optical distribution: Stanchion mounting at 25° with Type III optics for broad, uniform coverage. Business impact: flexible positioning reduces labor during installation and retrofit projects. Application: outdoor jurisdictions and industrial facilities requiring directional, wide-beam lighting. Voltage compatibility and dimmable driver: 100-277 Vac and 127-250 Vdc input with a dimmable driver. Business impact: reduces inventory by supporting multiple supply voltages and allows controls integration for energy savings. Application: retrofit projects and new builds with variable power infrastructure. Wiring and convenience: Six-pole terminal block simplifies field wiring and reliability. Business impact: faster commissioning, fewer electrical faults, and improved fault isolation. Application: installation in hazardous locations with constrained access. Durability and maintenance: 1-1/2" trade size, glass lens, and no guard design optimize serviceability and compatibility with common mounting hardware. Business impact: minimizes downtime during maintenance and extends asset life. Application: industrial sites with stringent safety and serviceability needs.
Get a Quick Quote for a Eaton Crouse-Hinds VMVL-7-J-R3-UNV1-TB6
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds VMVL-7-J-R3-UNV1-TB6?
Enquire Now
FAQs
When deploying VMVL-7-J-R3-UNV1-TB6 in hazardous locations, plan for stanchion mounting at 25 degrees, use the 1-1/2 inch trade size, and wire through the six-pole terminal block for reliable field connections. Ensure power is within 100-277 Vac or 127-250 Vdc and verify IP66/NEMA 4X ratings match the site protection requirements. Follow Eaton’s installation sheets for instruction alignment and safe commissioning.
The VMVL-7-J-R3-UNV1-TB6 delivers 7000 lumens with a high efficiency of 127 lm/W, providing broad, even illumination across hazardous locations. This reduces the number of fixtures needed to achieve target lux levels, lowers energy consumption, and supports compliant, high-visibility lighting for safety-critical operations in tough environments.
This luminaire carries NEC/CEC and IECEx/ATEX certifications, including Class I, Division 2 and Zone 2, with IECEx/ATEX Zone 21 for dust-explosive environments. It also holds IP66 ingress protection and a NEMA 4X enclosure rating. Together, these certifications ensure compliance with global hazardous-location standards and industrial safety requirements.
The VMVL combines energy-efficient output, dimmable operation, and a rugged die-cast aluminum housing to minimize energy costs and maintenance downtime. Its broad voltage range reduces inventory complexity, while Type III optics provide targeted illumination, lowering overall installed lighting costs and extending service intervals in harsh environments.
Adopt a standard maintenance window for inspecting the glass lens, verify terminal torque on the six-pole block, and confirm voltage is de-energized before servicing. Keep spares for the die-cast housing components and lenses, and consult Eaton’s IF1882 and data sheets for replacement procedures. Regular cleaning and inspection help sustain IP66/NEMA 4X performance.