Eaton Crouse-Hinds VMVL-7-W-J-R1-G-UNV1 LED fixture - IP66
Part Number: VMVL-7-W-J-R1-G-UNV1
Manufacturer
Eaton Crouse-Hinds
Part number
VMVL-7-W-J-R1-G-UNV1
Category
Quick Summary
VMVL LED light fixture from Eaton Crouse-Hinds delivers reliable hazardous-location illumination for industrial plants. Facilities often struggle with HID replacements, frequent maintenance, and unreliable performance in harsh environments. This luminaire carries NEC/CEC and IECEx/ATEX certifications and is rated for Hazardous/Classified Locations, Zone 21, IP66 protection, and NEMA 4X durability, ensuring safe operation in wet, dusty, and explosive atmospheres. Its warm white light, 7000 lumens, and 127 lm/W efficiency translate to lower energy costs and fewer relamping cycles. In addition, a dimmable driver and a broad voltage range support flexible controls and worldwide installation, reducing total cost of ownership while meeting stringent regulatory and safety requirements.
Product Information
Extended Description
VMVL-7-W-J-R1-G-UNV1 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Champ VMVL LED fixture, Warm white, 175W HID equivalent, Wire guard, Glass lens, 7000 lumens, 127 lm/W, Die cast aluminum, Stanchion 25° angled, Type I, 1-1/2" trade size, 100-277 Vac, 127-250 Vdc, 61W
Product Name
Eaton Crouse-Hinds series Champ VMVL LED light fixture
Catalog Number
VMVL-7-W-J-R1-G-UNV1
UPC
662276896147
Product Length/Depth
15.07 in
Product Height
12.85 in
Product Width
11.62 in
Product Weight
22.5 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IEC IECEx/ATEX
NEC hazardous rating
Class I, Division 2 Class I, Zone 2 Class II, Division 1 Class III
IECEx/ATEX hazardous rating
Zone 21
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Lumens
7000
Lumens per watt
127
Color temperature
Warm white
Mounting Method
Stanchion 25° angled
Trade size
1-1/2"
Optical distribution
Type I
Guard type
Wire
Voltage rating
100-277 Vac, 127-250 Vdc
Frequency rating
50/60 Hz
Wattage
61W
Dimming
Dimmable driver
Power factor
> 0.90
Equivalent luminaire
175W HID
Material
Die cast aluminum
Lens material
Heat and impact resistant glass
SP3D Design Package - Champ VMVL LED Hazardous Area Light Fixtures
Crouse-Hinds series Champ VMVL LED Luminaires - 3,000 to 13,000 lumens brochure
Crouse-Hinds series Champ VMVL LED Luminaires - 3,000 to 13,000 lumens brochure
Crouse-Hinds series Champ VMVL LED Luminaires - 3,000 to 13,000 lumens brochure
Crouse-Hinds series Champ VMVL LED luminaires - 3,000 to 13,000 lumens catalog page
IF 1888 - Champ VMVL and PVML Driver Replacement
IF 1888 - Champ VMVL and PVML Driver Replacement
Champ VMV LED Hazardous Area
Champ VMV LED Hazardous Area
The VMVL series leverages LED technology to deliver high-lumen efficiency while reducing maintenance intervals and energy consumption. Feature → Business Impact → Application: 7000 lumens at 127 lm/W reduces energy use versus traditional HID, cutting utility costs and extending service intervals for manufacturing floors and processing plants. The 61W input replaces a 175W HID equivalent, delivering immediate energy savings and smaller line-item impact on capital budgets, ideal for facilities upgrading older lighting. The wide voltage range 100-277 Vac and 127-250 Vdc supports global sites and retrofit projects, enabling standardized lighting across multinational operations. A dimmable driver facilitates integration with building management and surge-lighting controls, improving process visibility and asset monitoring while lowering maintenance labor. Rugged die-cast aluminum housing, heat- and impact-resistant glass, and a wire guard enable long service life in dusty, damp, or vibrating environments, translating to lower replacement costs and less downtime. The stanchion 25° angled mounting and Type I optical distribution optimize light placement for walkways, mezzanines, and hazardous locations, reducing glare and improving worker safety. With IP66, NEMA 4X, and Zone 21 ratings, this fixture meets stringent safety standards necessary for chemical plants, oil & gas facilities, and mining operations, supporting compliance while lowering risk. Overall, the VMVL fixture combines durable construction, regulatory compliance, and energy efficiency to deliver a compelling total ownership cost advantage for industrial operators.
Get a Quick Quote for a Eaton Crouse-Hinds VMVL-7-W-J-R1-G-UNV1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds VMVL-7-W-J-R1-G-UNV1?
Enquire Now
FAQs
VMVL-7-W-J-R1-G-UNV1 uses a 1-1/2 inch trade size with a stanchion mounting arrangement set at 25 degrees. Its compact dimensions (15.07 in length, 12.85 in height, 11.62 in width) and rugged housing simplify retrofits on standard hazardous-location stanchions. Ensure existing mounts meet the 1-1/2 inch conduit size and provide proper conduit entry protection to maintain IP66/NEMA 4X ratings.
This luminaire holds NEC/CEC and IECEx/ATEX standards, with hazardous-location ratings including Zone 21, Class I and II, Division 1 and Division 2, plus Class III. It carries IP66 ingress protection and a NEMA 4X enclosure rating, making it suitable for demanding environments such as chemical plants, offshore facilities, and mining operations.
Ideal for hazardous and classified locations, it serves chemical processing, oil and gas facilities, mining operations, power plants, and outdoor industrial spaces. Its rugged build, 7000-lumen output, and warm white light enhance visibility on walkways, platforms, and staging areas while meeting strict safety and compliance requirements.
With 7000 lumens at 127 lm/W and a 61W input, the VMVL delivers HID-equivalent brightness with significantly lower energy use. The dimmable driver enables occupancy or daylight harvesting control, reducing energy costs further. Its long-life design and protective glass lens lower maintenance and replacement cycles, improving overall uptime in harsh environments.
Choose proper mounting and wiring to preserve IP66 and NEMA 4X integrity, verify voltage compatibility (100-277 Vac or 127-250 Vdc), and use the dimmable driver in coordination with control systems to optimize energy use. Regular inspection of the die-cast housing, lens, and guard for damage will sustain protection against dust, moisture, and vibration.