Eaton Crouse-Hinds WSRD103541CH Interlocked Receptacle - 3R

Part Number: WSRD103541CH
Manufacturer
Eaton Crouse-Hinds
Part number
WSRD103541CH

Quick Summary

Interlocked receptacle with enclosed safety disconnect from Eaton Crouse-Hinds is designed to provide controlled, safe power delivery for industrial equipment. This solution addresses maintenance risk by ensuring intentional disconnection prior to servicing. It carries NEC/CEC compliance and a NEMA 3R enclosure rating for reliable operation in non-hazardous locations, with a robust sheet steel build and brass contacts. Engineered for 480/600 VAC systems at 100A, it supports high-cycle environments while enabling fast, safe lockout during maintenance. For procurement teams, this combination of safety, reliability, and compliance translates to lower downtime, fewer field errors, and improved operator protection in everyday plant operations.

Product Information

Extended Description

WSRD103541CH Eaton Crouse-Hinds: Eaton Crouse-Hinds series Arktite WSRD interlocked receptacle with enclosed safety disconnect switch, 100A, Three-wire, three-pole, Brass contacts, Solid door, Non-fused, Style 1, Cutler-Hammer, Sheet steel, Spring door, 480/600 Vac
Product Name
Eaton Crouse-Hinds series Arktite WSRD interlocked receptacle with enclosed safety disconnect switch
Catalog Number
WSRD103541CH
UPC
662276534674
Product Length/Depth
11.14 in
Product Height
31.05 in
Product Width
10.21 in
Product Weight
35 lb
Area classification
Ordinary/Non-Hazardous Locations
Standards type
NEC/CEC
NEMA Rating
3R 12
Enclosure type
With switch
Door style
Solid
Amperage Rating
100A
Fusing
Non-fused
Grounding style
Style 1
Configuration
Three-wire, three-pole
Material
Sheet steel
Contact material
Brass
Voltage rating
480 Vac/600 Vac
Manufacturer
Cutler-Hammer
Receptacle style
Spring door
Feature → Business Impact → Application: Interlocked receptacle with enclosed safety disconnect switch provides a verifiable, fail-secure disconnection at 100A, reducing the risk of accidental energization during maintenance. This translates to tangible safety and compliance gains on the factory floor, especially for equipment using 480/600 VAC power. Application: ideal for ordinary/non-hazardous locations in process lines or packaging equipment where reliable shutdown is essential for worker protection and regulatory alignment. Feature → Business Impact → Application: Arktite WSRD uses a solid sheet steel enclosure with a spring door and a solid door design, delivering rugged durability in harsh environments and minimizing ingress. Application: suitable for hard-wearing industrial areas where protection against impact and dust is critical. Feature → Business Impact → Application: Brass contact material and three-wire, three-pole configuration optimize electrical conductivity and fault tolerance, supporting dependable, safe power distribution at 100A. Application: perfect for high-demand machines requiring sturdy, repeatable connections. Feature → Business Impact → Application: Rated for 480 Vac/600 Vac operations and NEC/CEC standards, ensuring regulatory compliance and predictable performance. Application: supporting cross-border projects and multi-national facilities with consistent electrical protection. This product’s compatibility with Cutler-Hammer Arktite line further simplifies replacement and spare-part strategies, reducing inventory complexity and maintenance costs. Feature → Business Impact → Application: Non-fused design reduces maintenance steps and simplifies field diagnostics, enabling quicker fault isolation and service. Application: beneficial in facilities prioritizing uptime and streamlined maintenance routines.

Get a Quick Quote for a Eaton Crouse-Hinds WSRD103541CH

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds WSRD103541CH? Enquire Now

FAQs

Begin by verifying service voltage and confirming the 100A rating. Mount the unit to a compatible enclosure, connect three-wire, three-pole conductors to the designated terminals, and attach the grounding lead per local codes. Install the solid door and ensure the interlock mechanism properly engages to prevent energization when the door is open. Finally, test the safety disconnect under supervision to confirm lockout capability.
Yes. This model is specified for 480 VAC and 600 VAC operation and uses a sheet steel enclosure with a spring door. The three-wire, three-pole configuration supports robust, safe power distribution in industrial settings, while the sheet steel construction provides durable protection against mechanical impact and environmental contaminants in ordinary locations.
Ideal for non-hazardous locations where safe maintenance shutdown is critical, such as manufacturing lines, packaging equipment, and automation panels. Its enclosed disconnect switch ensures deliberate de-energization before service, while the 100A rating supports high-current loads typical in industrial machinery and process equipment.
The WSRD103541CH adheres to NEC/CEC standards and carries a NEMA 3R rating, indicating suitability for outdoor or semi-exposed environments. It is UL-listed for safety, with documentation available for certification verification. The product is designed for ordinary/non-hazardous locations, aligning with typical industrial installation requirements.
The interlocked design minimizes misoperation and prevents accidental energization, reducing maintenance accidents and downtime. Its rugged sheet steel enclosure and durable brass contacts offer long-term reliability, lowering replacement and service costs. By standardizing on a compliant, easy-to-service unit, facilities can streamline spares, training, and maintenance workflows.