Eaton X37 Condulet Form 7 conduit outlet body - NEMA 12
Part Number: X37
Quick Summary
X37 Condulet Form 7 conduit outlet body provides rugged 1 inch terminations for industrial enclosures. Engineers often encounter installation delays from ill-fitting parts and non-UL components that disrupt schedules. This unit aligns with NEC/CEC standards, carries a NEMA 12 rating, and is approved for Ordinary/Non-Hazardous Locations, ensuring reliability in dusty, damp, or compliant environments. With its Feraloy iron alloy construction and Form 7 geometry, it simplifies wiring integration, reduces field modifications, and lowers spare-parts inventory, delivering measurable efficiency gains for panel builders and maintenance teams.
Product Information
Extended Description
X37 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Condulet Form 7 conduit outlet body, Feraloy iron alloy, X shape, 1"
Product Name
Eaton Crouse-Hinds series Condulet Form 7 conduit outlet body
Catalog Number
X37
UPC
782274746104
Product Length/Depth
7.25 in
Product Height
4 in
Product Width
2.25 in
Product Weight
2.75 lb
Area classification
Ordinary/Non-Hazardous Locations
Standards type
NEC/CEC
NEMA Rating
12
Shape
X
Trade size
1"
Material
Feraloy iron alloy
Crouse-Hinds series Form 7 catalog page
Condulet Form 7 Conduit Outlet Bodies and Covers UL certification
Condulet Form 7 Conduit Outlet Bodies and Covers UL certification
IF 863 - Conduit Body Wire Pulling
IF 863 - Conduit Body Wire Pulling
Condulet Form 7 Industrial Grade Conduit Bodies
Condulet Form 7 Industrial Grade Conduit Bodies
Industrial Fittings Wire Fill Chart
Industrial Fittings Wire Fill Chart
Feature: Feraloy iron alloy construction offers superior corrosion and impact resistance. Business Impact: longer service life and reduced maintenance costs in harsh environments. Application: outdoor and damp industrial installations where protection against dust and moisture matters. Feature: X shape Form 7 design with a 1 in trade size enables compact wiring and efficient cable management. Business Impact: smaller panel footprints and faster assembly, lowering labor time. Application: control panels, motor control centers, and equipment enclosures in manufacturing facilities. Feature: NEC/CEC compliance and NEMA 12 rating provide code-friendly protection. Business Impact: simplified compliance and durable enclosure protection in Ordinary/Non-Hazardous locations. Application: plants, warehouses, and process lines requiring reliable dust and water resistance. Feature: UL certification references and installation resources streamline procurement. Business Impact: faster spec-to-install cycles and fewer vendor questions. Application: project bidding, field commissioning, and maintenance planning. Feature: compatibility with IF 863 wire pulling guidance and Form 7 catalog information enables smooth installation. Business Impact: reduced miswires and easier future maintenance. Application: field retrofits and new builds across industrial wiring networks.
Get a Quick Quote for a Eaton Crouse-Hinds X37
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds X37?
Enquire Now
FAQs
For X37 installation use the 1 in trade size Condulet Form 7 body with compatible covers and fittings; refer to IF 863 for conduit body wire pulling guidance and ensure proper sealing. Plan a clean wiring path, verify enclosure rating, and confirm area classification aligns with Ordinary locations. Use UL-listed components to maintain NEMA 12 protection and complete the setup with correct grounding per NEC/CEC requirements.
Key specs include a 1 in trade size and Form 7 X-shaped body made from Feraloy iron alloy. It carries a NEMA 12 protection rating and NEC/CEC compliance, suitable for Ordinary/Non-Hazardous Locations. The catalog number is X37 and UPC is 782274746104, supporting reliable integration into standard wiring diagrams and panel assemblies.
The X37 Condulet Form 7 is rated for Ordinary/Non-Hazardous Locations with a NEMA 12 enclosure protection level. It is not intended for hazardous (classified) locations. For hazardous environments, consider Form 7 options with higher ingress protection and appropriate certifications and consult UL and regional standards to select a compliant alternative.
It adheres to NEC/CEC standards and carries a NEMA 12 rating. The product has UL certification references for Condulet Form 7 conduit outlet bodies and covers, including Canada-specific listings. Area classification is Ordinary/Non-Hazardous Locations, ensuring compliance across typical industrial facilities and non-hazardous workspaces.
The X37 reduces field rework through robust Feraloy iron alloy construction and a compact 1 in Form 7 design, cutting downtime and spare-parts costs. Its NEC/CEC compliance and NEMA 12 protection lower compliance risk, while readily available catalog resources and wiring guides speed procurement, installation, and future maintenance.