Eaton Crouse-Hinds XDT3B30 Dry-Type Transformer - Hazardous/Classified Locations

Part Number: XDT3B30
Manufacturer
Eaton Crouse-Hinds
Part number
XDT3B30

Quick Summary

Eaton Crouse-Hinds XDT3B30 dry-type transformer delivers safe, reliable voltage conversion for hazardous-location electrical systems in demanding industrial settings. This 30 kVA unit steps 480 Vac down to 208Y/120 Vac in a three-phase, 60 Hz configuration, helping control panels and instrumentation run safely at lower voltages. In rugged plant environments, uptime and ignition protection are critical; the XDT3B30’s resin-encapsulated winding and painted steel enclosure minimize moisture ingress, contaminant exposure, and maintenance cycles. Key certifications matter in regulated facilities: NEC/CEC compliance, Class I, Division 2 hazardous ratings, and NEMA 3R enclosure support installation in indoor and exposed outdoor locations. For engineers and procurement, the model also integrates with standard Eaton/Crouse-Hinds power-distribution ecosystems, improving compatibility and total-cost-of-ownership.

Product Information

Extended Description

XDT3B30 Eaton Crouse-Hinds: Eaton Crouse-Hinds series XDT dry-type transformer, 60 Hz, 30 kVA, Painted steel, Three-phase, 480 Vac, 208Y/120 Vac, Copper windings, Resin encapsulated
Product Name
Eaton Crouse-Hinds series XDT dry-type transformer
Catalog Number
XDT3B30
UPC
662276424616
Product Length/Depth
25.15 in
Product Height
26.57 in
Product Width
12.76 in
Product Weight
620 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2
NEMA Rating
3R
Type
Resin encapsulated
Phase
Three-phase
Primary voltage
480 Vac
Secondary Voltage
208Y/120 Vac
Frequency rating
60 Hz
Material
Painted steel
Special features
Copper windings
Feature: Resin-encapsulated winding and copper windings provide superior moisture and contaminant resistance, enabling reliable operation in hazardous locations. Business impact: reduces insulation failures and maintenance costs while extending mean time between failures. Application: ideal for motors, drives, and instrumentation in Class I, Division 2 environments. The resin encapsulation also contributes to consistent performance across temperature swings typical in chemical plants and refineries.\n\nFeature: 480 VAC primary to 208Y/120 VAC secondary, three-phase, 60 Hz design. Business impact: standardizes power delivery to control panels and instrumentation, simplifying panel wiring and improving overall system efficiency. Application: used in process control rooms and hazardous-area substations requiring stable low-voltage supplies.\n\nFeature: Painted steel enclosure with NEMA 3R rating. Business impact: proven durability against dust, moisture, and outdoor exposure, reducing corrosion-related downtime. Application: suitable for indoor and protected outdoor installations, including outdoor switchgear enclosures in industrial yards.\n\nFeature: NEC/CEC compliance and Class I, Division 2 hazardous-location rating. Business impact: ensures regulatory alignment, streamlining approvals, audits, and installation in regulated facilities. Application: critical for oil & gas, chemical processing, and mining environments where safety and compliance are non-negotiable.\n\nFeature: Dimensions and weight (25.15 in L × 12.76 in W × 26.57 in H; 620 lb). Business impact: predictable footprint for equipment layouts and rack/maneline integration, enabling accurate space planning and reduced installation time. Application: suitable for existing assemblies and retrofit projects where space is constrained.\n\nInsight: The XDT3B30 aligns with Eaton/Crouse-Hinds power-distribution ecosystems, delivering compatibility with standard installation practices and service workflows, which translates to lower training costs and faster onboarding for maintenance teams.

Get a Quick Quote for a Eaton Crouse-Hinds XDT3B30

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds XDT3B30? Enquire Now

FAQs

For XDT3B30 installations in Hazardous/Classified Locations, verify area classification and ensure compliance with NEC/CEC requirements. Mount in a protected area or NEMA 3R enclosure, maintain proper clearances for cooling, and connect 480 VAC primary to 208Y/120 VAC secondary in a three-phase, 60 Hz configuration. Use approved certified wiring methods and follow manufacturer installation instructions to minimize ignition risks and maximize uptime.
The XDT3B30 is a 30 kVA resin-encapsulated dry-type transformer with a 480 VAC primary and 208Y/120 VAC secondary. It operates at 60 Hz and is a three-phase unit with copper windings. These specifications support safe, efficient step-down power for control systems, instrumentation, and motors in hazardous locations, while meeting NEC/CEC and Class I, Division 2 requirements.
Yes. The XDT3B30 carries NEC/CEC compliance with a Class I, Division 2 hazardous-location rating and an area classification of Hazardous/Classified Locations. It also features a NEMA 3R enclosure suitable for indoor and weather-exposed installations. This combination supports regulatory approvals, audits, and safer operation in regulated facilities such as chemical plants and refineries.
Typical applications include powering control panels, instrumentation, and drives in hazardous environments. The transformer steps down 480 VAC to 208Y/120 VAC for smart sensors and PLCs while maintaining isolation and reliability. It is well-suited for oil and gas facilities, chemical processing plants, and mining operations where compliance and robust performance under harsh conditions are essential.
Maintenance is minimized by the resin-encapsulated windings and durable painted-steel enclosure, which resist moisture and contaminants. Regular checks should include enclosure integrity, connection torque, cooling pathways, and inspection for signs of corrosion or damage. Follow manufacturer guidelines for periodic testing and lubrication of any accessories, and document maintenance to support lifecycle cost optimization.