Eaton XDT3B45 Dry-type Transformer - Class I, Division 2

Part Number: XDT3B45
Manufacturer
Eaton Crouse-Hinds
Part number
XDT3B45

Quick Summary

XDT3B45 dry-type transformer delivers safe, reliable power conversion for industrial control panels in hazardous locations. Engineers often face maintenance and compliance challenges when selecting equipment for Class I, Division 2 environments, where moisture, dust, and chemical exposure can degrade performance. This unit aligns with NEC/CEC standards and carries a NEMA 3R enclosure rating, supporting weatherproof and impact-resistant service in rugged settings. With resin encapsulation and copper windings, it combines excellent thermal management with high efficiency, while the 480 Vac to 208Y/120 Vac secondary delivers stable control voltages for motors and automation hardware. In practice, it translates to lower downtime, easier installation, and a clearer path to regulatory compliance for plant-wide power distribution.

Product Information

Extended Description

XDT3B45 Eaton Crouse-Hinds: Eaton Crouse-Hinds series XDT dry-type transformer, 60 Hz, 45 kVA, Painted steel, Three-phase, 480 Vac, 208Y/120 Vac, Copper windings, Resin encapsulated
Product Name
Eaton Crouse-Hinds series XDT dry-type transformer
Catalog Number
XDT3B45
UPC
662276424623
Product Length/Depth
28.17 in
Product Height
26.49 in
Product Width
14.66 in
Product Weight
811 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2
NEMA Rating
3R
Type
Resin encapsulated
Phase
Three-phase
Primary voltage
480 Vac
Secondary Voltage
208Y/120 Vac
Frequency rating
60 Hz
Material
Painted steel
Special features
Copper windings
The XDT3B45 is a 45 kVA, three-phase transformer rated for 60 Hz operation with a 480 Vac primary and 208Y/120 Vac secondary, enabling seamless integration with standard industrial power systems. Feature → Business Impact → Application: The resin-encapsulated design provides enhanced moisture and chemical resistance, reducing insulation failures in harsh environments and lowering maintenance costs for chemical plants or oil & gas facilities. Feature → Business Impact → Application: Copper windings offer improved efficiency and lower hot-spot temperatures, delivering measurable energy savings and extended equipment life for critical control panels in manufacturing lines. Feature → Business Impact → Application: Painted steel construction with a NEMA 3R enclosure supports reliable outdoor or damp-area installation, minimizing corrosion risk and enabling versatile site deployments. Feature → Business Impact → Application: NEC/CEC compliance and Class I, Division 2 hazardous-location ratings give procurement teams a clear path to regulatory acceptance, simplifying audits and safety reviews. Feature → Business Impact → Application: Compact dimensions (28.17 in x 26.49 in x 14.66 in) and a substantial 811 lb weight balance installation needs with stable mounting, facilitating integration in existing plant racks and layouts. This combination of rugged build, electrical performance, and compliance-oriented design makes the XDT3B45 a trusted solution for hazardous-area power distribution in process industries and aggressive environments.

Get a Quick Quote for a Eaton Crouse-Hinds XDT3B45

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds XDT3B45? Enquire Now

FAQs

When installing the XDT3B45 in hazardous locations, ensure proper area classification (Hazardous/Classified Locations) and secure mounting to support the 811 lb weight. Verify 480 Vac primary and 208Y/120 Vac secondary wiring with copper conductors, maintain adequate clearance, and follow NEC/CEC guidelines. Use a suitable enclosure rating (NEMA 3R) for weather exposure and protect terminations from vibration or impact during maintenance.
Key specs include 45 kVA rating, three-phase, 60 Hz, 480 Vac primary, and 208Y/120 Vac secondary. The transformer uses copper windings and is resin-encapsulated, with a painted steel enclosure. Dimensions are 28.17 in L, 26.49 in H, 14.66 in W, and weight about 811 lb, making it suitable for moderate footprint installations in control rooms or outdoors in protected areas.
Yes. The XDT3B45 is designed for hazardous/classified locations with Class I, Division 2 ratings and NEC/CEC compliance, plus a NEMA 3R enclosure. Its resin encapsulation and copper windings support reliable operation in chemical environments, while the 480 Vac to 208Y/120 Vac output fits standard control panels and automation equipment.
The transformer carries NEC/CEC compliance, a Class I, Division 2 hazardous-location rating, and a NEMA 3R enclosure. These certifications facilitate regulatory approvals, enable safer operation in hazardous environments, and support compliance during audits and procurement reviews for industrial facilities.
Resin encapsulation protects windings from moisture, dust, and chemical exposure, reducing insulation degradation and common field failures. This translates to lower maintenance costs, longer mean time between failures (MTBF), and improved reliability for critical processes in harsh environments such as chemical plants and oil refineries.