Eaton Crouse-Hinds XDT3E3X Dry-Type Transformer - NEMA 4X
Part Number: XDT3E3X
Quick Summary
The Eaton Crouse-Hinds XDT3E3X dry-type transformer provides reliable 3 kVA power for hazardous-location control panels. In hazardous-area projects, space, heat, and certification hurdles slow timelines. The XDT3E3X carries NEC/CEC compliance, Class I Division 2 hazardous rating, and a NEMA 4X enclosure for tough environments. Its 316 stainless steel enclosure and copper windings deliver durable, low-maintenance performance, while resin encapsulation protects windings from moisture and contaminants. This combination supports industrial automation and power-distribution needs with a compact footprint and proven reliability in demanding facilities.
Product Information
Extended Description
XDT3E3X Eaton Crouse-Hinds: Eaton Crouse-Hinds series XDT dry-type transformer, 60 Hz, 3 kVA, 316 stainless steel, Three-phase, 600 Vac, 480Y/277 Vac, Copper windings, Resin encapsulated
Product Name
Eaton Crouse-Hinds series XDT dry-type transformer
Catalog Number
XDT3E3X
UPC
662276445789
Product Length/Depth
19.37 in
Product Height
11.34 in
Product Width
8.87 in
Product Weight
125 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2
NEMA Rating
4X
Type
Resin encapsulated
Phase
Three-phase
Primary voltage
600 Vac
Secondary Voltage
480Y/277 Vac
Frequency rating
60 Hz
Material
316 stainless steel
Special features
Copper windings
SP3D Design Package - XDT and XTT Hazardous Area Transformers
XDT and XTT Hazardous Area Transformers Flyer
XDT and XTT Hazardous Area Transformers catalog page
XDT and XTT Hazardous Area Transformers UL certification
XDT and XTT Hazardous Area Transformers UL certification
IF XDT - XDT Series Hazardous Area Transformers
XDT Hazardous Area Transformers
XDT Hazardous Area Transformers
Feature → Business Impact → Application: Three-phase 3 kVA transformer with 600 Vac primary and 480Y/277 Vac secondary at 60 Hz enables direct integration with standard plant power networks, delivering consistent voltage conversion and reduced wiring complexity. This translates to faster commissioning and lower field wiring risk in control cabinets and switchgear assemblies used in chemical plants and refineries. Feature → Business Impact → Application: Resin-encapsulated construction with copper windings offers moisture and chemical resistance, minimizing winding degradation and maintenance frequency; ideal for corrosive environments and harsh production lines in hazardous locations. Feature → Business Impact → Application: 316 stainless steel enclosure combined with a NEMA 4X rating delivers rugged enclosure protection, supporting compliance and long service life in outdoor or damp electrical rooms. Feature → Business Impact → Application: Class I, Division 2 hazardous-location rating and NEC/CEC standards streamline procurement and installation, reducing regulatory delays for process automation projects. Feature → Business Impact → Application: Compact dimensions (19.37 in L × 8.87 in W × 11.34 in H) and 125 lb weight provide installation flexibility in restricted spaces, enabling easier mounting near equipment and instrumentation. Feature → Business Impact → Application: Copper windings improve efficiency and heat management, lowering operating losses and extending transformer life in continuous-operation environments such as packaging lines and water treatment plants. Feature → Business Impact → Application: Overall design supports quick field service and compatibility with 600 Vac/480Y/277 Vac power networks, reducing downtime during maintenance and upgrades in industrial facilities.
Get a Quick Quote for a Eaton Crouse-Hinds XDT3E3X
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds XDT3E3X?
Enquire Now
FAQs
When installing XDT3E3X in hazardous locations, ensure mounting in a suitable enclosure and maintain recommended clearances for ventilation. Utilize the 316 stainless enclosure and resin-encapsulated windings to minimize moisture ingress, and align primary and secondary connections with 600 Vac and 480Y/277 Vac ratings. Follow NEC/CEC guidelines and manufacturer installation instructions for safe operation.
Key specs: three-phase, 3 kVA, primary 600 Vac, secondary 480Y/277 Vac, 60 Hz, copper windings, resin encapsulation. Choose this model for hazardous-area instrumentation and control panels that require a compact, rugged transformer with reliable step-down capability and compliant installation in Class I, Division 2 environments.
Yes. The XDT3E3X is designed for hazardous locations with NEC/CEC compliance, Class I Division 2 rating, and a NEMA 4X enclosure. Its resin-encapsulated windings, copper conductors, and 316 stainless steel construction offer chemical resistance and moisture protection, making it well-suited for chemical processing and other demanding industrial applications.
The transformer carries NEC/CEC standards, Class I Division 2 hazardous location rating, and a NEMA 4X enclosure. These certifications reduce regulatory risk, simplify procurement for hazardous-area projects, and ensure suitability for damp, corrosive, or outdoor environments in industrial facilities.
The resin-encapsulated design and copper windings reduce moisture-related failures and heat losses, lowering maintenance costs and extending service life. Its compact footprint and robust enclosure decrease installation time and space requirements, delivering faster project timelines and a lower total cost of ownership in continuous-operation facilities.