Eaton Crouse-Hinds XLHS12626200B Ex-CELL Enclosure - IP66
Part Number: XLHS12626200B
Manufacturer
Eaton Crouse-Hinds
Part number
XLHS12626200B
Quick Summary
Ex-CELL enclosure by Eaton Crouse-Hinds protects electrical gear in hazardous locations. This rugged stainless steel enclosure is designed to withstand corrosive environments while keeping internal components safe from dust, washdowns, and water ingress. Engineers often confront ingress, corrosion, and maintenance challenges in offshore, chemical, or mining facilities; this unit addresses those pains with a rigid 316L body and a hinged, bolted cover for rapid field service. Certifications include IECEx/ATEX for hazardous areas, IP66 ingress protection, and NEMA 4X weatherproofing, ensuring compliance across global markets. By combining compact dimensions—260 x 260 x 203 mm—with a 400 A capacity and 690 Vac/Vdc rating, it delivers reliable power protection without sacrificing space. This supports scalable installations and streamlined procurement for industrial projects.
Product Information
Extended Description
XLHS12626200B Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 400A, 260 x 260 x 203 mm enclosure size, 316L stainless steel, 0 gland plates, Cover fixed with hinges and bolts, Horizontal lugs, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLHS12626200B
EAN
4251958138598
Product Length/Depth
203 mm
Product Height
260 mm
Product Width
260 mm
Area classification
Hazardous/Classified Locations
Standards type
IECEx/ATEX NEC/CEC IEC
NEC hazardous rating
Class I, Division 2 Class I, Zone 1 Class II, Division 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
260 x 260 x 203 mm
Number of gland plates
0
Type
Horizontal lugs
Special features
Cover fixed with hinges and bolts
Crouse-Hinds series Stainless Steel Enclosures Solutions brochure
Crouse-Hinds series Ex-CELL Stainless Steel or Painted Steel Enclosures catalog page
Crouse-Hinds series Ex-CELL empty enclosures - IECEx Certificate of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - IECEx Certificate of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - IECEx Certificate of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - IECEx Certificate of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - IECEx Certificate of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - IECEx Certificate of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - IECEx Certificate of Conformity
ENK10673 Ex-Cell Operating Instructions
Feature: 316L stainless steel construction provides superior corrosion resistance in aggressive environments. Benefit: Extends service life and reduces corrosion-related maintenance costs for installations in chemical plants, offshore platforms, and mining sites. Application: Ideal for hazardous locations where durability and cleanability are critical. Feature: IP66 and NEMA 4X ratings deliver proven ingress protection and weather resistance. Benefit: Ensures reliable operation in washdowns and harsh outdoor conditions, supporting regulatory compliance and uptime. Application: Suitable for outdoor substations and hazardous-area control panels. Feature: Enclosure size 260 x 260 x 203 mm with 400 A capacity and 690 Vac/Vdc rating. Benefit: Balances compact footprint with high electrical capacity, enabling dense panel layouts and robust power distribution. Application: Panels with high-current feeds in space-constrained industrial installations. Feature: Cover fixed with hinges and bolts; 0 gland plates; horizontal lugs. Benefit: Facilitates quick maintenance and clean wiring routes, reducing assembly time and potential sealing points. Application: Field service scenarios where fast access and reliable sealing matter. Feature: Hazardous/classified locations area classification; IECEx/ATEX and NEC/CEC standards. Benefit: Regulatory alignment across geographies, simplifying procurement and reducing risk of non-compliance. Application: Global oil & gas, chemical, and processing facilities requiring certified enclosures.
Get a Quick Quote for a Eaton Crouse-Hinds XLHS12626200B
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds XLHS12626200B?
Enquire Now
FAQs
The Ex-CELL enclosure uses horizontal lugs for mounting and a hinged, bolted cover, with 0 gland plates that simplifies wiring routes. Its compact 260 x 260 x 203 mm footprint fits tight panels, while maintaining robust protection. For installation, align with standard enclosure supports and add glands only if required by the specific apparatus.
Yes. It is certified for hazardous areas with IECEx/ATEX standards and NEC/CEC compliance. The enclosure carries area classification for Hazardous/Classified Locations and supports Class I, Division 2 and Zone 1, making it appropriate for oil, gas, chemical, and other hazardous environments.
Dimensions are 260 x 260 x 203 mm (H x W x D). It is configured with horizontal lugs for panel mounting and a 316L stainless steel body. The design omits gland plates, enabling clean installation, while the hinged cover supports quick access during maintenance.
The XLHS12626200B carries IP66 and NEMA 4X protection, IECEx/ATEX and NEC/CEC standards, and NEC hazardous ratings including Class I, Division 2, and Zone 1. These certifications provide regulatory confidence for global deployment across hazardous location markets.
Stainless steel 316L construction offers corrosion resistance, reducing replacement and painting costs. The hinged, bolted cover simplifies field maintenance, and the 0 gland plate design minimizes sealing points. Together, these features lower downtime and maintenance labor while extending service life in challenging environments.