Eaton Crouse-Hinds XLHS12626201 Ex-CELL enclosure - IP66/NEMA 4X
Part Number: XLHS12626201
Manufacturer
Eaton Crouse-Hinds
Part number
XLHS12626201
Quick Summary
XLHS12626201 Ex-CELL enclosure protects high‑current control gear in hazardous locations. In harsh environments, corrosion and ingress can drive costly downtime and frequent replacements. This enclosure is built from 316L stainless steel and delivers robust protection while supporting easy maintenance. It carries IECEx/ATEX and NEC/CEC certifications, plus IP66 ingress protection and a NEMA 4X rating, ensuring safe operation in extreme conditions. The 260 x 260 x 203 mm footprint and 400 A capability align with mid‑to‑high power automation applications, while the one gland plate and horizontal lugs simplify installation and future expansion, delivering measurable business value through reliability and compliance.
Product Information
Extended Description
XLHS12626201 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 400A, 260 x 260 x 203 mm enclosure size, 316L stainless steel, 1 gland plate, Horizontal lugs, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLHS12626201
EAN
4251958138604
Product Length/Depth
203 mm
Product Height
260 mm
Product Width
260 mm
Area classification
Hazardous/Classified Locations
Standards type
IEC IECEx/ATEX NEC/CEC
NEC hazardous rating
Class I, Division 2 Class I, Zone 1 Class II, Division 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
260 x 260 x 203 mm
Number of gland plates
1
Type
Horizontal lugs
Crouse-Hinds series Stainless Steel Enclosures Solutions brochure
Crouse-Hinds series Ex-CELL Stainless Steel or Painted Steel Enclosures catalog page
Crouse-Hinds series Ex-CELL empty enclosures - UKCA Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - UKCA Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - UKCA Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - UKCA Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - UKCA Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - UKCA Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - UKCA Declaration of Conformity
ENK10673 Ex-Cell Operating Instructions
316L stainless steel construction provides superior corrosion resistance in chemical, offshore, and washdown environments, extending service life and reducing replacement costs while maintaining mechanical integrity under vibration and temperature fluctuations. IP66 ingress protection combined with a NEMA 4X rating shields sensitive electrical gear from dust, water, and chemicals, minimizing maintenance cycles and downtime in outdoor and harsh indoor setups. Ex-CELL enclosures are purpose‑built for hazardous locations, enabling safe installations in Class I, Division 2 and Zone 1 areas, which accelerates project timelines and reduces risk during commissioning. The 400 A rating with horizontal lugs supports high‑current feeders while the single gland plate simplifies cable entry and gland management, improving wiring quality and reducing installation time. Compact 260 x 260 x 203 mm dimensions fit constrained cabinets and retrofit projects, promoting standardization across sites and lowering spare parts inventory. IECEx/ATEX and NEC/CEC certifications provide global compliance, easing cross-border deployments and reducing engineering effort for regulatory approvals. A 690 Vac/Vdc rating covers both AC and DC automation drives, enabling versatile power distribution within a single enclosure and reducing part numbers, inventory, and logistics complexity.
Get a Quick Quote for a Eaton Crouse-Hinds XLHS12626201
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds XLHS12626201?
Enquire Now
FAQs
The XLHS12626201 Ex-CELL enclosure is designed for hazardous locations and supports Class I Division 2 and Zone 1 environments. It uses horizontal lugs, a single gland plate, and 316L stainless steel, providing straightforward wiring, reliable gland management, and easy retrofit into existing systems without redesigning the panel layout.
Key specs include 400 A current rating, 690 Vac/Vdc capability, IP66 ingress protection, and NEMA 4X protection. Dimensions are 260 x 260 x 203 mm with one gland plate. Material is 316L stainless steel, offering excellent corrosion resistance in tough environments such as chemical plants or offshore installations.
Yes. The enclosure carries IECEx/ATEX and NEC/CEC certifications, plus hazardous location protection ratings (Class I Division 2, Zone 1; Class II Division 2). Its corrosion‑resistant material and robust sealing make it well suited for process areas, offshore rigs, and other demanding environments.
Ex-CELL enclosures like XLHS12626201 meet IECEx/ATEX and NEC/CEC standards, with additional protection from IP66 and NEMA 4X. These certifications support global deployment and simplify regulatory approvals for projects across multiple regions.
The combination of 316L stainless steel durability, high ingress protection, hazardous-location compliance, and reduced maintenance translates to lower lifecycle costs, fewer unplanned downtimes, and standardized parts across sites. The single gland plate and fixed dimensions further streamline procurement and installation, delivering faster project completion and long‑term cost savings.