Eaton XLHS13026131 Ex-CELL Enclosure - IP66, NEMA 4X

Part Number: XLHS13026131
Manufacturer
Eaton Crouse-Hinds
Part number
XLHS13026131

Quick Summary

Ex-CELL Enclosure provides a rugged stainless steel housing for electrical control panels in hazardous locations. Operators encounter corrosion, dust ingress, and strict compliance hurdles when selecting protective enclosures for harsh environments. This Ex-CELL is certified for NEC/CEC, IECEx/ATEX, and IP66/NEMA 4X, offering global acceptability and rugged sealing. With 316L stainless steel construction, a single gland plate, and horizontal lugs, installation is straightforward and maintenance intervals are extended, reducing downtime and lifecycle costs. For plant engineers and procurement teams, it translates to reliable protection, easier spare strategy, and consistent performance across facilities.

Product Information

Extended Description

XLHS13026131 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 400A, 305 x 260 x 127 mm enclosure size, 316 mm horizontal fixing center, 203 mm vertical fixing center, 316L stainless steel, 1 gland plate, Horizontal lugs, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLHS13026131
EAN
4251958138659
Product Length/Depth
127 mm
Product Height
305 mm
Product Width
260 mm
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IECEx/ATEX IEC
NEC hazardous rating
Class I, Division 2 Class II, Division 2 Class I, Zone 1
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
305 x 260 x 127 mm
Number of gland plates
1
Type
Horizontal lugs
Stainless steel 316L construction delivers outstanding corrosion resistance in chemical, offshore, and washdown environments, extending service life and lowering maintenance costs. Business impact: reduced downtime and predictable long-term operating expense; application: control panels in hazardous locations where moisture, chemicals, or salt spray are present. The enclosure size and design integrate a single gland plate and horizontal lugs, enabling fast field wiring and flexible internal layouts. Business impact: faster installations and easier future upgrades; application: retrofits and new builds with tight mounting footprints. IP66 and NEMA 4X protection provide robust ingress sealing and weather resistance, safeguarding electronics from dust, water jets, and corrosive atmospheres. Business impact: compliant operations and fewer enclosure-related failures; application: critical production lines and safety systems in classified areas. NEC/CEC and IECEx/ATEX certifications ensure global applicability and audit readiness. Business impact: simplified international deployments and regulatory confidence; application: multi-site projects with shared equipment standards. The enclosure’s horizontal fixing centers (316 mm) and vertical centers (203 mm) support versatile mounting and alignment with standard frames. Business impact: reduced installation planning time and better integration with existing enclosures; application: modular plant architectures and scalable control rooms. A single gland plate reduces cabling complexity at entry points, while the 1-gland plate feature supports clean, organized wiring—translating to easier maintenance and inspection.

Get a Quick Quote for a Eaton Crouse-Hinds XLHS13026131

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds XLHS13026131? Enquire Now

FAQs

The Ex-CELL enclosure uses horizontal lugs and a 316 mm horizontal fixing center with a 203 mm vertical center, enabling flexible mounting on standard frames. A single gland plate simplifies cabling, reducing entry point complexity. Plan for secure grounding, correct seal installation, and alignment with nearby equipment to maximize ingress protection and serviceability in hazardous locations.
IP66 provides complete protection against dust ingress and powerful water jets, while NEMA 4X adds corrosion resistance in harsh environments. Together, they ensure enclosure integrity in chemical plants, offshore, and other classified locations, reducing maintenance frequency and extending equipment life in demanding automation applications.
Yes. The Ex-CELL enclosure is certified for NEC/CEC and IECEx/ATEX, aligning with global regulatory frameworks for hazardous locations. This certification simplifies cross-border deployments, supplier audits, and installation approvals across multiple sites while ensuring safe operation under local codes.
The enclosure measures 305 x 260 x 127 mm and uses 316L stainless steel, with one gland plate, horizontal lugs, and defined fixing centers. These features enable straightforward integration into existing control panels, support organized cabling, and accommodate standard mounting patterns, reducing rework during retrofits or new builds.
While initial cost may be higher than painted alternatives, the 316L stainless steel construction delivers superior corrosion resistance and longer service life in harsh environments, lowering maintenance, downtime, and replacement costs. Global certifications facilitate multi-site procurement, reducing audit and compliance expenses over the enclosure’s life cycle.