Eaton Crouse-Hinds XLHS13030152 Ex-CELL enclosure - IP66
Part Number: XLHS13030152
Manufacturer
Eaton Crouse-Hinds
Part number
XLHS13030152
Quick Summary
Ex-CELL enclosure protects electrical assemblies in hazardous locations with corrosion-resistant stainless steel. In harsh industrial environments, corrosion, ingress, and noncompliance threaten uptime and safety. This enclosure carries IECEx/ATEX and NEC/CEC certifications and meets IP66 and NEMA 4X protection, enabling safe operation across classified sites. With 316L stainless steel construction, a compact 305 x 305 x 152 mm footprint, and 2 gland plates, it supports robust, code-compliant installations. Horizontal lugs and fixed centers of 361 mm x 203 mm streamline mounting on existing frames. For engineers seeking durable, compliant stainless steel enclosures, this Ex-CELL solution delivers reliable protection, easier maintenance, and reduced downtime in hazardous-location projects, while supporting 690 Vac/Vdc control gear.
Product Information
Extended Description
XLHS13030152 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 400A, 305 x 305 x 152 mm enclosure size, 361 mm horizontal fixing center, 203 mm vertical fixing center, 316L stainless steel, 2 gland plates, Horizontal lugs, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLHS13030152
EAN
4251958138680
Product Length/Depth
152 mm
Product Height
305 mm
Product Width
305 mm
Area classification
Hazardous/Classified Locations
Standards type
IECEx/ATEX NEC/CEC IEC
NEC hazardous rating
Class II, Division 2 Class I, Division 2 Class I, Zone 1
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
305 x 305 x 152 mm
Number of gland plates
2
Type
Horizontal lugs
Crouse-Hinds series Stainless Steel Enclosures Solutions brochure
Crouse-Hinds series Ex-CELL Stainless Steel or Painted Steel Enclosures catalog page
Crouse-Hinds series Ex-CELL empty enclosures - TRCU
Crouse-Hinds series Ex-CELL empty enclosures - TRCU
Crouse-Hinds series Ex-CELL empty enclosures - TRCU
Crouse-Hinds series Ex-CELL empty enclosures - TRCU
Crouse-Hinds series Ex-CELL empty enclosures - TRCU
Crouse-Hinds series Ex-CELL empty enclosures - TRCU
Crouse-Hinds series Ex-CELL empty enclosures - TRCU
ENK10673 Ex-Cell Operating Instructions
316L stainless steel body provides excellent corrosion resistance, reducing maintenance costs and extending service life in chemical, oil and gas, and pharmaceutical plants. This translates to lower replacement frequency and safer, more reliable operation. The enclosure offers IP66 and NEMA 4X protection, delivering robust ingress and washdown resistance for harsh environments, which minimizes unplanned downtime and helps maintain process continuity. IECEx/ATEX and NEC/CEC certifications enable global deployment in Zone 1/Division 1 and Division 2 locations, ensuring compliance across regional safety standards and faster project approvals. The compact 305 x 305 x 152 mm size with horizontal lugs and 361 mm x 203 mm fixing centers simplifies retrofit and integration with existing frames, accelerating installation and reducing labor costs. Two gland plates provide straightforward cable routing for standard control gear, while the 690 Vac/Vdc rating supports diverse power and control circuits, enhancing system flexibility. Overall, the Ex-CELL enclosure combines rugged protection with installation efficiency, addressing common objections about corrosion, certification gaps, and maintenance burden in hazardous-location upgrades.
Get a Quick Quote for a Eaton Crouse-Hinds XLHS13030152
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds XLHS13030152?
Enquire Now
FAQs
The Ex-CELL enclosure uses horizontal lugs with a fixed center spacing of 361 mm horizontally and 203 mm vertically, designed for straightforward mounting on standard frames. It accepts two gland plates for cable routing and supports up to 690 Vac/Vdc control circuits, enabling flexible wiring layouts while maintaining safe enclosure integrity in hazardous locations.
It carries IECEx/ATEX and NEC/CEC certifications, addressing global compliance for hazardous locations. The enclosure is rated IP66 and NEMA 4X, ensuring ingress protection against dust, water jets, and corrosion, suitable for Zone 1/Division 1 environments and other classified locations.
Yes. The enclosure is rated for Class I Division 2 and Zone 1 (as well as Class II Division 2), enabling safe housing of electrical equipment in a wide range of hazardous-area applications, from oil and gas to chemical processing and power generation.
With two gland plates and horizontal lugs, the Ex-CELL enclosure supports organized cable entry and routing. The 305 x 305 x 152 mm footprint allows installation in tight spaces, while 690 Vac/Vdc capability accommodates a broad set of control devices, simplifying upgrades and reducing downtime during maintenance.
Constructed from 316L stainless steel, the enclosure delivers superior corrosion resistance in harsh process environments. Its IP66 and NEMA 4X ratings protect against dust and powerful water ingress, while IECEx/ATEX and NEC/CEC certifications ensure compliance across regions, reducing risk and extending service life in hazardous-location applications.