Eaton Crouse-Hinds XLHS15040251 Ex-CELL Enclosure - IECEx
Part Number: XLHS15040251
Manufacturer
Eaton Crouse-Hinds
Part number
XLHS15040251
Quick Summary
Ex-CELL enclosure by Eaton Crouse-Hinds protects electrical equipment in hazardous locations. This stainless steel solution addresses the challenge of maintaining safety and reliability in harsh environments where corrosion, dust ingress, and strict compliance requirements drive up risk and cost. Certified for IECEx/ATEX, NEC/CEC, IP66 and NEMA 4X, it delivers robust protection while supporting efficient installation and long service life. Engineers and procurement teams gain a scalable enclosure platform that aligns with hazardous-area regulations and corrosion resistance expectations, enabling easier maintenance, faster project turnover, and lower lifecycle costs. For customers prioritizing reliability, compliance, and total cost of ownership in industrial automation, the Ex-CELL XLHS15040251 is a strategic fit.
Product Information
Extended Description
XLHS15040251 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 400A, 508 x 406 x 254 mm enclosure size, 462 mm horizontal fixing center, 354 mm vertical fixing center, 316L stainless steel, 1 gland plate, Horizontal lugs, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLHS15040251
EAN
4251958139106
Product Length/Depth
254 mm
Product Height
508 mm
Product Width
406 mm
Area classification
Hazardous/Classified Locations
Standards type
IEC IECEx/ATEX NEC/CEC
NEC hazardous rating
Class II, Division 2 Class I, Division 2 Class I, Zone 1
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
508 x 406 x 254 mm
Number of gland plates
1
Type
Horizontal lugs
Crouse-Hinds series Stainless Steel Enclosures Solutions brochure
Crouse-Hinds series Ex-CELL Stainless Steel or Painted Steel Enclosures catalog page
Crouse-Hinds series Ex-CELL empty enclosures - EU Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - EU Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - EU Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - EU Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - EU Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - EU Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - EU Declaration of Conformity
ENK10673 Ex-Cell Operating Instructions
Feature → Business Impact → Application: 316L stainless steel construction delivers outstanding corrosion resistance in chemical plants and offshore environments, reducing replacement and maintenance intervals while extending service life. This minimizes downtime and safeguards sensitive equipment in hazardous locations. Feature → IP66 and NEMA 4X protection provides reliable ingress protection against dust, water jets, and harsh washdown conditions, enabling compliant operation in wet or dusty facilities and improving uptime. Feature → Enclosure size 508 x 406 x 254 mm with 462 mm horizontal fixing center and 354 mm vertical fixing center supports flexible mounting in retrofit projects and new builds, streamlining installation in constrained plant spaces. Feature → 400 A rating and 690 Vac/Vdc compatibility supports high-power control circuits without enclosure enclosure creep or overheating, improving overall system efficiency and safety. Feature → 1 gland plate and horizontal lug configuration simplify cable management and gland routing, reducing field assembly time and risk of improper sealing. Feature → IECEx/ATEX and NEC/CEC certifications, IP66, and NEMA 4X compliance provide a comprehensive regulatory package, reducing validation time for hazardous-area projects. Industry context: The Ex-CELL line is trusted for critical utility, process, and safety systems, where a robust stainless-steel enclosure translates to lower maintenance costs, fewer field faults, and easier audits. Compatibility and installation advantages include a factory-proven gland plate arrangement and standardized fixing centers, enabling quicker integration with existing panels and switchgear while meeting stringent safety standards.
Get a Quick Quote for a Eaton Crouse-Hinds XLHS15040251
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds XLHS15040251?
Enquire Now
FAQs
The Ex-CELL XLHS15040251 uses 316L stainless steel, IP66/NEMA 4X protection, and a single gland plate with horizontal lugs, making it straightforward to install in Class I/II, Division 2 or Zone 1 environments. The 462 mm horizontal and 354 mm vertical fixing centers support common mounting patterns, reducing field modification needs.
This enclosure supports up to 400 A with a 690 Vac/Vdc rating, providing robust protection for high-power control circuitry. It also carries IP66 and NEMA 4X ratings, and is suitable for hazardous locations per IECEx/ATEX and NEC/CEC classifications, ensuring compliance and safe operation in demanding environments.
Yes. The 316L stainless steel construction, corrosion resistance, IP66/NEMA 4X protection, and IECEx/ATEX compliance make it ideal for chemical processing, oil and gas, and offshore applications where exposure to chemicals, moisture, and dust is common.
The Ex-CELL enclosure carries IECEx and NEC/CEC certifications, IP66 and NEMA 4X ratings, and is rated for Hazardous/Classified Locations, including Class I, Division 2 and Zone 1, ensuring broad regulatory alignment for global projects.
The 316L stainless steel body provides superior corrosion resistance, reducing replacement frequency in harsh environments. The enclosure’s robust sealing (IP66/NEMA 4X) and standardized gland plate and lug configuration simplify maintenance, audits, and future upgrades, delivering lower total cost of ownership over the system lifecycle.