Eaton Crouse-Hinds XLHS15050303 Ex-CELL Enclosure - IP66
Part Number: XLHS15050303
Manufacturer
Eaton Crouse-Hinds
Part number
XLHS15050303
Quick Summary
XLHS15050303 Ex-CELL enclosure from Eaton Crouse-Hinds protects electrical assemblies in hazardous locations. Engineers often struggle with corrosion, ingress, and maintaining regulatory compliance in tough environments. This enclosure carries IP66 and NEMA 4X ratings, plus IECEx/ATEX and NEC/CEC certifications for hazardous or classified locations. Fabricated from 316L stainless steel with a compact 508 x 508 x 300 mm profile, it supports robust wiring in tight spaces. This combination translates to improved uptime, lower maintenance costs, and faster compliance demonstrations for automation projects. Its 3 gland plates, horizontal lugs, and 564 mm horizontal fixing center support flexible installation for control panels, drives, or field devices, while maintaining sealing integrity.
Product Information
Extended Description
XLHS15050303 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 400A, 508 x 508 x 300 mm enclosure size, 564 mm horizontal fixing center, 354 mm vertical fixing center, 316L stainless steel, 3 gland plates, Horizontal lugs, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLHS15050303
EAN
4251958139205
Product Length/Depth
300 mm
Product Height
508 mm
Product Width
508 mm
Area classification
Hazardous/Classified Locations
Standards type
IEC IECEx/ATEX NEC/CEC
NEC hazardous rating
Class II, Division 2 Class I, Zone 1 Class I, Division 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
508 x 508 x 300 mm
Number of gland plates
3
Type
Horizontal lugs
Crouse-Hinds series Stainless Steel Enclosures Solutions brochure
Crouse-Hinds series Ex-CELL Stainless Steel or Painted Steel Enclosures catalog page
Crouse-Hinds series Ex-CELL empty enclosures - EU Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - EU Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - EU Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - EU Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - EU Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - EU Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - EU Declaration of Conformity
ENK10673 Ex-Cell Operating Instructions
Feature: 316L stainless steel construction provides outstanding corrosion resistance and mechanical strength. Business Impact: Longer service life in chemical plants, offshore environments, and wash-down facilities reduces replacement cycles and maintenance costs. Application: Ideal for hazardous-location control panels and outdoor installations where exposure to moisture and chemicals is routine. Feature: Enclosure size and layout at 508 x 508 x 300 mm with 564 mm horizontal fixing center and 354 mm vertical fixing center. Business Impact: Streamlined installation planning and cabling with predictable mounting patterns and clearances. Application: Panel builders and engineers designing compact control enclosures in constrained spaces. Feature: IP66 ingress protection and NEMA 4X rating. Business Impact: Superior dust-tight and water-resistant performance, enabling reliable operation in wash-down and outdoor environments. Application: Food&Beverage, water treatment, and petrochemical facilities requiring robust protection. Feature: Certifications IECEx/ATEX and NEC/CEC for hazardous locations. Business Impact: Regulatory compliance across multiple jurisdictions, simplifying sales to global customers. Application: Oil & gas, chemical processing, mining, and other classified locations. Feature: Horizontal lugs and three gland plates. Business Impact: Flexible cable entry management and straightforward wiring access, saving installation time and reducing risk of damage to seals. Application: High-power drives, control circuits, and field instrumentation in industrial environments.
Get a Quick Quote for a Eaton Crouse-Hinds XLHS15050303
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds XLHS15050303?
Enquire Now
FAQs
The Ex-CELL enclosure uses a 508 x 508 x 300 mm footprint with 564 mm horizontal and 354 mm vertical fixing centers, plus 3 gland plates and horizontal lugs. This combination makes it straightforward to retrofit into existing panel layouts, aligns with common field wiring practices, and preserves sealing integrity during retrofits.
This enclosure carries IECEx/ATEX and NEC/CEC certifications, along with IP66 and NEMA 4X ratings. It is designed for hazardous or classified locations, providing compliance for Zone 1/Class I/II environments and enabling safe installation in petrochemical, mining, and chemical processing facilities.
Yes. Rated for 690 Vac/Vdc, the Ex-CELL enclosure supports high-power control panels and drive applications. The 316L steel construction, robust gland plate arrangement, and horizontal lug design facilitate reliable wiring for motor controllers, VFDs, and power distribution in demanding industrial settings.
Industries such as oil & gas, chemical processing, water treatment, mining, and offshore facilities benefit the most due to the combination of corrosion resistance, wash-down capability, hazardous-location certification, and robust mechanical design that supports both panel integration and field wiring.
The 316L stainless steel construction provides superior durability in corrosive environments, reducing replacement cycles. The enclosure’s sealing and gland plate arrangement simplify maintenance tasks and wire management, while compliance with multiple standards minimizes regulatory-related downtime and accelerates audits, delivering a favorable total cost of ownership over the device’s life.