Ex-CELL enclosure protects electrical components in hazardous locations across demanding industrial environments. Engineers often battle corrosion, space constraints, and complex compliance when selecting rugged enclosures for hazardous zones. This model is IECEx/ATEX and NEC/CEC certified, IP66 rated, and NEMA 4X, supporting safe operation in Zone 1 and Division 2 locations. The 610x610x254 mm size, 316L stainless steel, and one gland plate simplify installation and ongoing maintenance, while horizontal lugs with 666 mm by 445 mm fixing centers speed secure mounting in tight spaces. By meeting these standards, it delivers reliable, long-term protection for critical plant equipment, reducing downtime and total cost of ownership in hazardous environments.

Product Information

Extended Description

XLHS16060251 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 400A, 610 x 610 x 254 mm enclosure size, 666 mm horizontal fixing center, 445 mm vertical fixing center, 316L stainless steel, 1 gland plate, Horizontal lugs, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLHS16060251
EAN
4251958139489
Product Length/Depth
254 mm
Product Height
610 mm
Product Width
610 mm
Area classification
Hazardous/Classified Locations
Standards type
IEC IECEx/ATEX NEC/CEC
NEC hazardous rating
Class I, Division 2 Class II, Division 2 Class I, Zone 1
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
610 x 610 x 254 mm
Number of gland plates
1
Type
Horizontal lugs
316L stainless steel construction provides exceptional corrosion resistance and longevity for harsh environments such as chemical plants, offshore platforms, and mining facilities. This translates to lower maintenance costs and fewer shutdowns due to enclosure deterioration, enabling more reliable control system operation in hazardous locations. IP66 and NEMA 4X ratings guard against dust, water ingress, and corrosion from washdowns and sea air, reducing ingress-related failures and accelerating compliance during audits. The Ex-CELL enclosure offers a 610 x 610 x 254 mm footprint with one gland plate, giving engineers ample internal space for controllers, power distribution, and cabling while keeping enclosure footprints compact in crowded plant rooms. Horizontal lugs and fixed centers of 666 mm by 445 mm simplify mounting alignment, speeding installation and reducing on-site labor. IECEx/ATEX and NEC/CEC certifications, paired with hazardous-area ratings, streamline procurement and help ensure global compliance across projects. This enclosure is compatible with 690 Vac/Vdc systems and supports up to 400 A, enabling robust power handling for demanding control circuits. By leveraging standard documentation such as ENK10673 operating instructions and the available literature, commissioning teams can reduce setup time and ambiguities, improving overall project ROI.

Get a Quick Quote for a Eaton Crouse-Hinds XLHS16060251

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds XLHS16060251? Enquire Now

FAQs

Yes. The XLHS16060251 uses horizontal lugs with fixed centers of 666 mm by 445 mm, designed for quick alignment and secure mounting in constrained spaces. It ships with one gland plate and a 610x610x254 mm footprint, allowing straightforward integration into existing frames or panels. For installation guidance, refer to the ENK10673 Ex-Cell Operating Instructions and the manufacturer’s mounting recommendations to ensure compliant, vibration-resistant installation in hazardous areas.
This Ex-CELL enclosure is rated IP66 and NEMA 4X for robust ingress protection against dust, water, and corrosion. It is suitable for hazardous locations per NEC/CEC and IECEx/ATEX, with a hazardous rating of Class I, Division 2; Class II, Division 2; and Class I, Zone 1. The enclosure supports 690 Vac/Vdc operation and up to 400 A, providing ample headroom for control gear in demanding installations.
Absolutely. The 316L stainless steel construction, IP66/NEMA 4X protection, and hazardous-location certifications make it well-suited for chemical plants, offshore platforms, and mining facilities. Its corrosion resistance, rugged build, and sealed integrity help prevent downtime from environmental exposure, while the 610x610x254 mm size balances internal space with compact footprint for crowded plant rooms or vessel installations.
The XLHS16060251 Ex-CELL enclosure carries IECEx/ATEX and NEC/CEC standards, ensuring compliance across global markets. Its IP66 and NEMA 4X ratings address ingress protection and corrosion resistance, while the hazardous-location classifications cover Zone 1 and Division 2 environments. Documentation resources such as PESO certifications and installation instructions are available to support audits and regulator reviews.
Eaton provides installation and certification documentation including the ENK10673 Ex-Cell Operating Instructions and product literature. Access to brochures, catalog pages, and certification reports supports faster procurement and audit readiness. The enclosure's robust stainless steel construction and reliable certifications translate into reduced maintenance cycles, lower replacement costs, and improved total cost of ownership in hazardous-area applications.