Eaton Crouse-Hinds XLHS16060300 Ex-Cell Enclosure - IP66
Part Number: XLHS16060300
Manufacturer
Eaton Crouse-Hinds
Part number
XLHS16060300
Quick Summary
XLHS16060300 Ex-CELL enclosure from Eaton Crouse-Hinds provides a rugged, stainless-steel housing for hazardous-location electrical systems. In demanding industrial environments, protecting sensitive equipment from dust, water jets and chemical exposure is a persistent challenge, affecting uptime and maintenance costs. This model carries IECEx/ATEX and NEC/CEC certifications, plus IP66 and NEMA 4X ratings, delivering robust protection for Class I, Zone 1 and Division 2 installations. By pairing corrosion resistance with a compact 610 x 610 x 300 mm footprint and 400 A capacity, it supports scalable control architectures while meeting global compliance requirements. The Ex-Cell solution integrates smoothly with existing stainless enclosures programs and offers predictable total cost of ownership for safety-critical applications.
Product Information
Extended Description
XLHS16060300 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 400A, 610 x 610 x 300 mm enclosure size, 666 mm horizontal fixing center, 445 mm vertical fixing center, 316L stainless steel, 0 gland plates, Horizontal lugs, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLHS16060300
EAN
4251958139502
Product Length/Depth
300 mm
Product Height
610 mm
Product Width
610 mm
Area classification
Hazardous/Classified Locations
Standards type
IEC NEC/CEC IECEx/ATEX
NEC hazardous rating
Class I, Zone 1 Class II, Division 2 Class I, Division 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
610 x 610 x 300 mm
Number of gland plates
0
Type
Horizontal lugs
Crouse-Hinds series Stainless Steel Enclosures Solutions brochure
Crouse-Hinds series Ex-CELL Stainless Steel or Painted Steel Enclosures catalog page
Crouse-Hinds series Ex-CELL empty enclosures - EU-Type Examination Certificate
Crouse-Hinds series Ex-CELL empty enclosures - EU-Type Examination Certificate
Crouse-Hinds series Ex-CELL empty enclosures - EU-Type Examination Certificate
Crouse-Hinds series Ex-CELL empty enclosures - EU-Type Examination Certificate
Crouse-Hinds series Ex-CELL empty enclosures - EU-Type Examination Certificate
Crouse-Hinds series Ex-CELL empty enclosures - EU-Type Examination Certificate
Crouse-Hinds series Ex-CELL empty enclosures - EU-Type Examination Certificate
ENK10673 Ex-Cell Operating Instructions
Feature: 316L stainless steel construction → Business impact: superior corrosion resistance and durability in caustic or washdown environments. Application: chemical plants, offshore platforms, food-processing facilities. Feature: Enclosure size 610 x 610 x 300 mm and 400 A rating → Business impact: accommodates sizable control panels and power distribution with headroom for future expansion. Application: industrial automation cabinets in hazardous locations. Feature: IP66 and NEMA 4X ingress protection → Business impact: reliable dust, water, and splash protection reduces field maintenance and downtime. Application: outdoor installations and washdown areas. Feature: Hazardous/Classified Locations area classification → Business impact: global compliance for Class I, Zone 1 and Division 2 environments minimizes regulatory risk. Application: oil & gas, chemical processing, refineries. Feature: 0 gland plates and horizontal lugs → Business impact: simplified assembly and flexible glanding options for fast installation. Application: retrofit projects and modular control schemes. Feature: 690 Vac/Vdc electrical rating and 316L compatibility → Business impact: supports high-energy equipment while maintaining enclosure integrity. Application: high-power drives and control gear in harsh environments.
Get a Quick Quote for a Eaton Crouse-Hinds XLHS16060300
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds XLHS16060300?
Enquire Now
FAQs
Installation requires securing the enclosure to a defined mounting surface using the horizontal lug arrangement and 666 mm fixing centers horizontally, with 445 mm vertical centers. Ensure complies with local restrictions for Class I, Zone 1 locations and follow IECEx/ATEX installation guidelines. The 0 gland plates can be adapted with external glands as needed for your cable management.
The Ex-CELL enclosure meets IECEx/ATEX certifications for hazardous locations and IEC NEC/CEC standards for electrical equipment, alongside IP66 ingress protection and NEMA 4X enclosure integrity. It is certified for hazardous/classified locations, ensuring compliance in global industrial environments and simplifying regulatory approvals.
Yes. The enclosure specifies 690 Vac/Vdc compatibility and a 400 A current rating, making it suitable for high-power drives and control gear. Its stainless-steel construction and IP66/NEMA 4X protection help maintain reliable operation under high-energy, harsh conditions.
The 316L stainless steel body offers excellent corrosion resistance and durability in washdown and corrosive environments, reducing maintenance frequency. With IP66/NEMA 4X protection, it minimizes ingress-related issues, while horizontal lugs simplify field wiring and future upgrades.
Longer service life from corrosion resistance, reduced maintenance and fewer replacements drive down lifecycle costs. Compliance with IECEx/ATEX and NEC/CEC reduces regulatory risk, while the robust 610x610x300 mm footprint supports scalable automation, delivering predictable installation costs and faster time-to-operation.