Eaton XLHS16060303 Ex-CELL Enclosure - IP66 NEMA 4X
Part Number: XLHS16060303
Manufacturer
Eaton Crouse-Hinds
Part number
XLHS16060303
Quick Summary
Ex-CELL enclosure from Eaton Crouse-Hinds protects electrical equipment in hazardous locations within industrial plants. Many projects struggle with corrosion, difficult wiring access, and ensuring compliance under tight schedules. This enclosure line is designed for harsh environments, featuring 316L stainless steel construction, IP66 ingress protection, and NEMA 4X durability, suitable for both indoor and outdoor installations. It aligns with NEC/CEC and IECEx/ATEX standards, delivering reliable performance in Class I/II locations. By standardizing on a rugged stainless-steel Ex-CELL system, you gain reduced maintenance, faster installation, and predictable lifecycle costs, while keeping critical automation components secure in hazardous areas. Secondary benefits include compatibility with horizontal lugs, gland plates, and easy retrofits for existing cabinets. This combination supports safer commissioning and extends service life in demanding industrial environments.
Product Information
Extended Description
XLHS16060303 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 400A, 610 x 610 x 300 mm enclosure size, 666 mm horizontal fixing center, 445 mm vertical fixing center, 316L stainless steel, 3 gland plates, Horizontal lugs, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLHS16060303
EAN
4251958139526
Product Length/Depth
300 mm
Product Height
610 mm
Product Width
610 mm
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IEC IECEx/ATEX
NEC hazardous rating
Class II, Division 2 Class I, Zone 1 Class I, Division 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
610 x 610 x 300 mm
Number of gland plates
3
Type
Horizontal lugs
Crouse-Hinds series Stainless Steel Enclosures Solutions brochure
Crouse-Hinds series Ex-CELL Stainless Steel or Painted Steel Enclosures catalog page
Crouse-Hinds series Ex-CELL empty enclosures - EU-Type Examination Certificate
Crouse-Hinds series Ex-CELL empty enclosures - EU-Type Examination Certificate
Crouse-Hinds series Ex-CELL empty enclosures - EU-Type Examination Certificate
Crouse-Hinds series Ex-CELL empty enclosures - EU-Type Examination Certificate
Crouse-Hinds series Ex-CELL empty enclosures - EU-Type Examination Certificate
Crouse-Hinds series Ex-CELL empty enclosures - EU-Type Examination Certificate
Crouse-Hinds series Ex-CELL empty enclosures - EU-Type Examination Certificate
ENK10673 Ex-Cell Operating Instructions
316L stainless steel construction delivers exceptional corrosion resistance in corrosive process environments such as chemical processing, refinery, and offshore installations. That resilience translates to longer service life and lower maintenance costs, reducing unscheduled downtime and extending asset reliability across plants. The combination also supports easier cleaning and sanitization in facilities with stringent hygiene and regulatory oversight. Enclosure size 610 x 610 x 300 mm with 3 gland plates and horizontal lugs enables compact, clean wiring and flexible terminations for diverse control panel layouts. This geometry supports faster installation, easier field modifications, and reliable cable management in tight spaces, while preserving sealing integrity and reducing commissioning time. With consistent gland plate alignment and robust mounting provisions, technicians can perform retrofits with minimal disruption. IP66 ingress protection and a NEMA 4X rating provide robust dust, water jet, and corrosion protection. That combination is proven for outdoor, washdown, and hazardous-location installations, helping prevent water intrusion and corrosion-related failures that drive downtime. The enclosure’s stainless surface resists routine washdowns commonly used in industrial plants, supporting long-term reliability. Hazardous-location certifications with NEC/CEC and IECEx/ATEX cover Class I, Zone 1 and Class II, Division 2 classifications. These approvals support compliant project planning, risk assessments, and permit-ready deployments across chemical, oil & gas, and mining sectors. Having a single, traceable compliance package simplifies procurement and reduces the risk of non-conformance during audits. 690 Vac/Vdc rating supports high-power control gear and fast switching in centralized automation architectures. Together with 316L construction, it enables scalable, maintenance-friendly panels that tolerate voltage spikes and frequent servicing in demanding industrial environments. The voltage capability also aligns with modern motor drives and PLC networks, reducing the need for enclosure upgrades as systems scale. Compatibility with Ex-CELL catalogs, gland plates, horizontal lugs, and mounting provisions supports standardized installations across multiple facilities. Designed for easy retrofits and modular upgrades, the XLHS16060303 helps reduce lifecycle costs while maintaining safety margins and compliance. Support materials such as installation instructions and brochures streamline knowledge transfer for maintenance teams and contractors.
Get a Quick Quote for a Eaton Crouse-Hinds XLHS16060303
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds XLHS16060303?
Enquire Now
FAQs
The XLHS16060303 is a 316L stainless-steel cabinet designed for hazardous locations and automated control panels. It features a 610x610x300 mm footprint, 3 gland plates, horizontal lugs, IP66 protection, and NEMA 4X rating, making it suitable for chemical plants, oil & gas, and harsh washdown environments.
Yes. It supports high-power automation gear with a 690 Vac/Vdc rating and a 400 A class rating, enabling reliable motor drives, contactors, and power distribution within a rugged enclosure while maintaining safety and compliance.
The enclosure carries NEC/CEC and IECEx/ATEX certifications for Class I, Zone 1 and Class II, Division 2 hazardous locations, along with IP66 and NEMA 4X ratings, simplifying compliance planning and permit-ready deployments in chemical, petrochemical, mining, and offshore sectors.
Its 610x610x300 mm footprint, three gland plates, and horizontal lugs are designed for compact wiring and flexible cable routing. Enhanced gland plate alignment and mounting provisions speed retrofits and minimize field wiring errors in space-constrained panels.
The 316L surface and IP66/NEMA 4X protection reduce corrosion-related maintenance and downtime, while added durability cuts spare-part needs. These factors collectively lower lifecycle costs and improve system availability in harsh environments.