Eaton Crouse-Hinds XLHS16076202 Ex-CELL enclosure - IP66 / NEMA 4X

Part Number: XLHS16076202
Manufacturer
Eaton Crouse-Hinds
Part number
XLHS16076202

Quick Summary

Eaton Crouse-Hinds Ex-CELL enclosure protects electrical assemblies in hazardous locations. Engineers often struggle to find enclosures that withstand corrosion, dust ingress, and restrictive area classifications while keeping installation simple. This model carries IECEx/ATEX and NEC/CEC compliance, plus NEMA 4X and IP66 ratings, delivering rugged performance in demanding environments. Built from 316L stainless steel with two gland plates and horizontal lugs, it minimizes maintenance down-time and simplifies wiring, improving total cost of ownership. The design supports heavy-duty applications in chemical processing, oil and gas, and offshore facilities, aligning with compliance-driven procurement and long-term reliability goals.

Product Information

Extended Description

XLHS16076202 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 400A, 610 x 762 x 203 mm enclosure size, 818 mm horizontal fixing center, 456 mm vertical fixing center, 316L stainless steel, 2 gland plates, Horizontal lugs, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLHS16076202
EAN
4251958139557
Product Length/Depth
203 mm
Product Height
610 mm
Product Width
762 mm
Area classification
Hazardous/Classified Locations
Standards type
IECEx/ATEX IEC NEC/CEC
NEC hazardous rating
Class I, Zone 1 Class II, Division 2 Class I, Division 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
610 x 762 x 203 mm
Number of gland plates
2
Type
Horizontal lugs
316L stainless steel construction delivers exceptional corrosion resistance, reducing replacement cycles and maintenance costs in aggressive atmospheres. This material choice supports long service life in chemical plants and offshore environments, ensuring reliable operation with minimal downtime. The enclosure's 610 x 762 x 203 mm size, IP66 protection, and NEMA 4X rating provide robust ingress protection for dusty and wet conditions, enabling safe electrical installations in demanding sites. IECEx/ATEX and NEC/CEC certifications remove regulatory barriers for global deployments, empowering multi-site projects with a single enclosure platform. Two gland plates and horizontal lugs simplify wiring and field connections, accelerating panel assembly and maintenance while reducing labor costs. Large horizontal and vertical fixing centers (818 mm and 456 mm) ease mounting to frames or walls, enhancing compatibility with existing infrastructure. The 690 Vac/Vdc rating supports high-power drives and control systems, reducing the need for alternative enclosures in power-dense applications. Overall, the Ex-CELL enclosure delivers predictable performance, extended service intervals, and lower lifecycle costs for harsh-environment controls.

Get a Quick Quote for a Eaton Crouse-Hinds XLHS16076202

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds XLHS16076202? Enquire Now

FAQs

The XLHS16076202 Ex-CELL enclosure is designed for hazardous locations and supports heavy-duty electrical assemblies up to 400 A. With dimensions of 610 x 762 x 203 mm, 818 mm horizontal fixing center, and 456 mm vertical fixing center, it fits standard frame layouts while accommodating robust busbars and cabling. The inclusion of 2 gland plates and horizontal lugs streamlines wiring during installation and service.
This Ex-CELL enclosure carries IECEx/ATEX and NEC/CEC standards, ensuring compliance for global projects. It also meets IP66 ingress protection and NEMA 4X ruggedization requirements, making it suitable for classified hazardous areas and demanding industrial environments. These certifications support regulatory acceptance, reducing the need for alternative enclosures on multi-site builds.
316L stainless steel provides superior corrosion resistance in saltwater, chemical vapors, and humid industrial settings, extending enclosure life and reducing maintenance. While ideal for offshore and chemical processing, it also offers long-term savings in any harsh location. If your environment is less corrosive, painted variants may be considered, but stainless steel generally improves lifecycle cost and reliability.
The Ex-CELL model features two gland plates and horizontal lugs for flexible wiring and straightforward field connections. The 818 mm horizontal and 456 mm vertical fixing centers simplify mounting to frames or walls, while the 610 x 762 mm footprint fits common install footprints. This combination reduces installation time, minimizes field modifications, and improves overall project predictability.
By delivering long-term corrosion resistance, robust ingress protection (IP66) and rugged NEMA 4X compatibility, the Ex-CELL enclosure reduces maintenance frequency and replacement costs. Regulatory compliance with IECEx/ATEX and NEC/CEC minimizes project risk and rework. These factors collectively lower downtime, extend service life, and provide a favorable return on investment for hazardous-location electrical infrastructure.