Eaton Crouse-Hinds XLHS16076401 Ex-Cell Enclosure-IP66 4X

Part Number: XLHS16076401
Manufacturer
Eaton Crouse-Hinds
Part number
XLHS16076401

Quick Summary

Ex-Cell enclosure from Eaton Crouse-Hinds protects critical electrical gear in hazardous locations. Design challenges like corrosion, ingress protection, and regulatory compliance can slow downtime and inflate maintenance costs. Certified for NEC/CEC, IECEx/ATEX, IP66, and NEMA 4X, it meets global standards for hazardous environments and harsh weather. Built from 316L stainless steel, XLHS16076401 offers long-term durability and predictable service life. The enclosure supports reliable electrical control and power cabinet installations in industrial automation and electrical infrastructure projects, with a 400A rating, one gland plate, horizontal lugs, and a compact footprint that simplifies mounting and retrofits. This combination of protection and performance translates to lower lifecycle costs and reduced risk for critical plant assets.

Product Information

Extended Description

XLHS16076401 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 400A, 610 x 762 x 400 mm enclosure size, 316L stainless steel, 1 gland plate, Horizontal lugs, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLHS16076401
EAN
4251958139649
Product Length/Depth
400 mm
Product Height
610 mm
Product Width
762 mm
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IECEx/ATEX IEC
NEC hazardous rating
Class I, Zone 1 Class I, Division 2 Class II, Division 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
610 x 762 x 400 mm
Number of gland plates
1
Type
Horizontal lugs
316L stainless steel construction delivers superior corrosion resistance in chemical, offshore, and wash-down environments. This materially reduces maintenance cycles and downtime while maintaining enclosure integrity. The 610 Ă— 762 Ă— 400 mm footprint provides scalable space for control gear and cable management, enabling straightforward retrofits in existing lineups and minimizing panel redesign costs. IP66 sealing and a NEMA 4X rating protect against dust, water ingress, and harsh washdowns, reducing unwanted outages and extending service life in challenging facilities. Certifications including NEC/CEC and IECEx/ATEX ensure global compliance, simplifying procurement across multi-site operations and easing regulatory audits. A single gland plate and horizontal lugs streamline installation, cabling, and future expansions, translating to faster project delivery and lower total cost of ownership. The 400A rating supports sizeable power distribution needs without compromising safety or enclosure integrity, making it ideal for motor drives and large control systems in heavy industry.

Get a Quick Quote for a Eaton Crouse-Hinds XLHS16076401

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds XLHS16076401? Enquire Now

FAQs

Installing the XLHS16076401 Ex-Cell enclosure requires attention to site classification, particularly Class I, Zone 1 or Division 2 locations. Mounting should follow the enclosure’s horizontal lug configuration for stable panel integration, and the single gland plate simplifies cable entry planning. Ensure cable management complies with NEC/CEC and IECEx/ATEX requirements, and verify suitable bonding and grounding practices to maintain IP66 integrity during service life.
The Ex-CELL enclosure is rated for 400 A and supports 690 Vac/Vdc, delivering robust current handling for motor drives and control circuits. IP66 protection ensures dust-tight sealing and protection against powerful water jets, while the NEMA 4X rating adds corrosion resistance for demanding environments. Coupled with 316L stainless steel, these specs translate to dependable performance in harsh settings.
Yes. The enclosure is designed for Hazardous/Classified Locations with NEC/CEC and IECEx/ATEX certifications. It supports Class I, Zone 1 and Class I, Division 2, ensuring compliance for explosive or flammable atmospheres. This makes it suitable for oil & gas, chemical processing, and other high-risk industrial installations while maintaining safe control cabinet operation.
The Ex-CELL enclosure carries NEC and CEC standards, IECEx and ATEX certification, and an IP66 rating with NEMA 4X protection. It is built for hazardous locations and supports global regulatory requirements, simplifying cross-border procurement and compliance documentation for multinational projects.
The 316L stainless steel construction delivers superior corrosion resistance, reducing preventive maintenance frequency in aggressive environments. IP66/NEMA 4X protection lowers ingress-related repair costs, while the durable build extends service life, lowering total cost of ownership. The compact 400 A design with a single gland plate also reduces installation time and spare part needs, improving overall project ROI.