Eaton Crouse-Hinds XLHS17650204 Ex-CELL Enclosure - IP66

Part Number: XLHS17650204
Manufacturer
Eaton Crouse-Hinds
Part number
XLHS17650204

Quick Summary

The Eaton Crouse-Hinds Ex-CELL enclosure is a rugged stainless steel housing designed for hazardous locations. Engineers often struggle with corrosion, dust ingress, and regulatory compliance during field installs. This Ex-CELL enclosure carries IECEx/ATEX and NEC/CEC certifications, IP66 ingress protection, and a NEMA 4X rating for reliable service in chemical, offshore, or plant environments. With a 400 A rating and a compact 762 x 508 x 203 mm footprint, it accommodates modern control gear without sacrificing safety. Featuring 316L stainless steel, 4 gland plates, and horizontal lugs, it supports fast, compliant installations while reducing lifecycle costs and maintenance downtime.

Product Information

Extended Description

XLHS17650204 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 400A, 762 x 508 x 203 mm enclosure size, 563 mm horizontal fixing center, 608 mm vertical fixing center, 316L stainless steel, 4 gland plates, Horizontal lugs, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLHS17650204
EAN
4251958139663
Product Length/Depth
203 mm
Product Height
762 mm
Product Width
508 mm
Area classification
Hazardous/Classified Locations
Standards type
IEC NEC/CEC IECEx/ATEX
NEC hazardous rating
Class I, Division 2 Class I, Zone 1 Class II, Division 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
762 x 508 x 203 mm
Number of gland plates
4
Type
Horizontal lugs
Feature: 316L stainless steel construction; Business Impact: exceptional corrosion resistance in harsh environments; Application: chemical plants, offshore platforms, and process facilities where washdown and chemical exposure are common. The material choice directly lowers replacement costs and extends service life. Feature: IP66 and NEMA 4X ratings; Business Impact: superior ingress protection for reliable operation in outdoor, damp, or dusty installations; Application: outdoor substations and rugged industrial enclosures where moisture and particulates are present. Feature: 4 gland plates and horizontal lugs; Business Impact: flexible cabling entry and straightforward mounting for fast installation; Application: scalable control panels with multiple feeds and compact horizontal layouts. Feature: Hazardous/location area classification and certified protections; Business Impact: ensures regulatory compliance and safe operation in Zone 1/2 or Division 1/2 environments; Application: oil & gas, chemical processing, mining, and energy plants. Feature: 762 x 508 x 203 mm enclosure size with 400 A rating; Business Impact: accommodates larger controls and power circuits without enclosure expansion; Application: medium-size switchgear and controller assemblies. Feature: 316L stainless steel durability combined with gasketed seals; Business Impact: reduced maintenance cycles, lower total cost of ownership, and safer field service; Application: environments requiring frequent inspections or washdowns. Compatibility and installation: designed to integrate with standard mounting centers (563 mm horizontal fixing center, 608 mm vertical fixing center) for seamless retrofits or new builds; Application: retrofit projects or new installations in demanding facilities. Industry insight: Ex-CELL solutions are favored where long-term reliability and regulatory clearance are non-negotiable, enabling operators to minimize non-production time and maximize throughput.

Get a Quick Quote for a Eaton Crouse-Hinds XLHS17650204

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds XLHS17650204? Enquire Now

FAQs

The XLHS17650204 Ex-CELL enclosure carries IECEx/ATEX and NEC/CEC certifications, along with IP66 ingress protection and a NEMA 4X rating. It is approved for Hazardous/Classified Locations, supporting Class I and II environments and Zone 1/2 installations, ensuring regulatory compliance across international markets.
Yes. The enclosure is rated for 400 A and configured to house larger protection devices and control gear. Its 762 x 508 x 203 mm footprint, 316L stainless steel construction, and four gland plates with horizontal lugs enable safe, scalable assemblies suitable for demanding hazardous-location projects.
Ex-CELL features four gland plates and horizontal lugs for flexible cable entry and rapid mounting. Its 563 mm horizontal and 608 mm vertical fixing centers simplify alignment with existing frames, while the 316L stainless steel body and gasketed seals maintain IP66/NEMA 4X integrity during installation and operation.
Industries including oil & gas, chemical processing, mining, offshore operations, and other facilities with hazardous-area requirements benefit from Ex-CELL. The combination of IECEx/ATEX and NEC/CEC certifications, along with IP66 and 4X ratings, supports safe, compliant electrical protection in harsh environments.
Regular inspection of seals and gland plate integrity is advised to maintain IP66 performance. Inspect for corrosion on 316L stainless steel, verify fastener torque, and ensure all certification labels remain legible. Routine washdowns or chemical exposure should be accounted for in preventive maintenance to preserve NEMA 4X and hazardous-location compliance.