Eaton Crouse-Hinds XLHS17650253 Ex-CELL Enclosure - IP66

Part Number: XLHS17650253
Manufacturer
Eaton Crouse-Hinds
Part number
XLHS17650253

Quick Summary

Eaton Crouse-Hinds Ex-CELL enclosure protects electrical gear in hazardous locations for industrial installations. Engineers often struggle with corrosion, contamination, and safety compliance when housing control panels in harsh environments. It carries IP66 ingress protection, NEMA 4X ratings, and IECEx/ATEX along with NEC/CEC certifications to meet global standards. This enclosure combines corrosion-resistant 316L stainless steel with 3 gland plates for flexible, maintenance-friendly installations. For project teams, it enables scalable, compliant panel housing across chemical, oil & gas, and manufacturing facilities. Users value long-term durability and a robust barrier against wash-downs, while integrators benefit from standardized mounting and easier retrofits in evolving plant layouts.

Product Information

Extended Description

XLHS17650253 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 400A, 762 x 508 x 254 mm enclosure size, 563 mm horizontal fixing center, 608 mm vertical fixing center, 316L stainless steel, 3 gland plates, Horizontal lugs, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLHS17650253
EAN
4251958139687
Product Length/Depth
254 mm
Product Height
762 mm
Product Width
508 mm
Area classification
Hazardous/Classified Locations
Standards type
IEC IECEx/ATEX NEC/CEC
NEC hazardous rating
Class II, Division 2 Class I, Zone 1 Class I, Division 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
762 x 508 x 254 mm
Number of gland plates
3
Type
Horizontal lugs
Feature: Corrosion-resistant 316L stainless steel construction. Business Impact: Delivers superior durability in chemical, offshore, and wash-down environments, reducing corrosion-related downtime and maintenance costs. Application: Ideal for chemical plants, water treatment facilities, and oil & gas processing where environmental exposure is high. Feature: IP66 ingress protection and NEMA 4X rating. Business Impact: Ensures reliable operation in dusty, wet, and hazardous areas, supporting compliance with strict safety standards. Application: Offshore platforms, refineries, and hazardous-location installations requiring resilient enclosure performance. Feature: Large enclosure size (762 x 508 x 254 mm) with three gland plates and horizontal lugs. Business Impact: Facilitates flexible interior mounting and quick installation with standardized fixing centers, shortening project schedules. Application: Panel mounting in space-constrained plant layouts and retrofit projects. Feature: Horizontal lugs and 563 mm/608 mm fixing centers. Business Impact: Simplifies alignment and reduces installation errors, enabling faster UPS or PLC retrofits. Application: Factory automation and process control in hazardous environments. Feature: IECEx/ATEX and NEC/CEC certifications. Business Impact: Removes compliance bottlenecks for multi-region deployments, lowering regulatory risk. Application: Global oil, gas, chemical, and mining operations. Feature: Documentation and accessories availability. Business Impact: Provides installation guidance and validation materials, reducing commissioning time. Application: System integrators and maintenance teams coordinating with Eaton resources and standards.

Get a Quick Quote for a Eaton Crouse-Hinds XLHS17650253

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds XLHS17650253? Enquire Now

FAQs

When installing the XLHS17650253 Ex-CELL enclosure in hazardous zones, co-locate units to minimize wiring runs, use the horizontal lugs for quick mounting, and align with the 563 mm horizontal and 608 mm vertical fixing centers. Ensure gland plates remain accessible for cable entry, and follow ENK10673 Ex-Cell operating guidance to guarantee proper seal integrity and safe operation.
Yes. The Ex-CELL enclosure is certified for IECEx/ATEX and NEC/CEC compliance, with area classification suitable for Hazardous/Classified Locations. It also carries IP66 ingress protection and NEMA 4X ratings, supporting broad regulatory acceptance and safer installations across regions.
The enclosure is made from 316L stainless steel, measuring 762 mm high, 508 mm wide, and 254 mm deep. It includes three gland plates and horizontal lugs for flexible interior mounting and expedited field installation in demanding environments.
With 316L stainless steel, IP66/NEMA 4X protection, and robust sealing, the Ex-CELL enclosure reduces ingress-related failures and corrosion-driven outages. The three gland plates enable neat, configurable cable management, while horizontal lugs simplify mounting and retrofit tasks, maintaining uptime and reducing maintenance cycles.
A full range of resources is available, including the Ex-Cell Operating Instructions ENK10673, stainless steel enclosures brochure, and catalog pages. Certification reports (TRCU, EU DoC, PESO, and more) and installation guidance support safe commissioning and compliant field installations.