Ex-CELL enclosure from Eaton Crouse-Hinds provides rugged stainless housing for electrical gear in hazardous locations. This enclosure protects critical equipment while withstanding corrosive environments and demanding service conditions. For engineers and procurement teams, the challenge is maintaining enclosure integrity under harsh field conditions while staying compliant with global standards — and this product addresses that with robust construction and clear certifications. It is certified to NEC/CEC and IECEx/ATEX, with IP66 ingress protection and a NEMA 4X rating for moisture, dust, and corrosion resistance. In addition to safety compliance, the 762 x 508 x 300 mm enclosure size and 316L material support long-term reliability and easier maintenance, delivering lifecycle cost savings and faster project execution.
Product Information
Extended Description
XLHS17650300 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 400A, 762 x 508 x 300 mm enclosure size, 563 mm horizontal fixing center, 608 mm vertical fixing center, 316L stainless steel, 0 gland plates, Horizontal lugs, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLHS17650300
EAN
4251958139694
Product Length/Depth
300 mm
Product Height
762 mm
Product Width
508 mm
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IECEx/ATEX IEC
NEC hazardous rating
Class I, Division 2 Class I, Zone 1 Class II, Division 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
762 x 508 x 300 mm
Number of gland plates
0
Type
Horizontal lugs
Crouse-Hinds series Stainless Steel Enclosures Solutions brochure
Crouse-Hinds series Ex-CELL Stainless Steel or Painted Steel Enclosures catalog page
Crouse-Hinds series Ex-CELL empty enclosures - Certificate of Compliance
Crouse-Hinds series Ex-CELL empty enclosures - Certificate of Compliance
Crouse-Hinds series Ex-CELL empty enclosures - Certificate of Compliance
Crouse-Hinds series Ex-CELL empty enclosures - Certificate of Compliance
Crouse-Hinds series Ex-CELL empty enclosures - Certificate of Compliance
Crouse-Hinds series Ex-CELL empty enclosures - Certificate of Compliance
Crouse-Hinds series Ex-CELL empty enclosures - Certificate of Compliance
ENK10673 Ex-Cell Operating Instructions
Feature: 316L stainless steel construction provides superior corrosion resistance in harsh environments. Business Impact: Extends service life in chemical processing, offshore and mining applications, reducing maintenance cycles. Application: Ideal for heavy-duty control panels exposed to humidity, chemicals, or salt spray. Feature: Enclosure size 762 x 508 x 300 mm with horizontal lugs and 563 mm horizontal fixing center / 608 mm vertical fixing center. Business Impact: Eases mounting and alignment with standard frames, accelerating installation and reducing field wiring errors. Application: Controls equipment in compact plant footprints or retrofit projects.Feature: IP66 ingress protection and NEMA 4X rating. Business Impact: Delivers reliable protection against dust, water, and corrosion, lowering risk of downtime in demanding environments. Application: Oil & gas, chemical plants, water treatment, and other hazardous locations.Feature: 0 gland plates. Business Impact: Simplifies cable routing and reduces modification time during installation, lowering project cost and lead times. Application: New builds and upgrades where clean, fast cabling is essential.Feature: 400 A rating with 690 Vac/Vdc capability. Business Impact: Supports high-current feeders and robust control power without enclosure changes, improving system reliability. Application: Main distribution panels, motor control centers, and large control assemblies in industrial automation. Feature: Horizontal lugs and standardized fixing centers. Business Impact: Enables straightforward mounting and compatibility with existing frames, cutting on-site customization. Application: Retrofit projects and multi-panel installations in chemical and energy facilities. Together these features deliver measurable outcomes: longer equipment life, lower maintenance costs, faster installation, and strong regulatory compliance across NEC/CEC and IECEx/ATEX, making the Ex-CELL enclosure a reliable choice for hazardous-location automation projects.
Get a Quick Quote for a Eaton Crouse-Hinds XLHS17650300
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds XLHS17650300?
Enquire Now
FAQs
The XLHS17650300 Ex-CELL enclosure is designed for hazardous and classified locations, meeting NEC/CEC and IECEx/ATEX standards. Its 316L stainless steel body, IP66 protection, and NEMA 4X rating ensure reliable performance in oil, gas, chemical, and mining environments. The enclosure accommodates up to 400 A assemblies and aligns with horizontal lug mounting centers for straightforward retrofits.
This enclosure carries NEC/CEC and IECEx/ATEX certifications, as well as IEC standards, ensuring compliance across North American and international markets. It is rated IP66 and NEMA 4X, providing robust ingress protection and suitability for hazardous locations, helping you meet site regulatory requirements with confidence.
Key specs include 762 x 508 x 300 mm dimensions, 316L stainless steel construction, 0 gland plates, horizontal lugs, and fixing centers of 563 mm (horizontal) and 608 mm (vertical). The enclosure supports up to 400 A and 690 Vac/Vdc, making it suitable for high-power control and protection in demanding environments.
The 0 gland plates reduce cabling modifications and simplify entry points, while the stainless steel body resists corrosion, lowering maintenance frequency. Horizontal lugs and standardized fixing centers streamline mounting, wiring, and field upgrades, enabling faster commissioning and reduced total cost of ownership in harsh environments.
Yes. The Ex-CELL enclosure is explicitly designed for hazardous/classified locations with NEC/CEC and IECEx/ATEX certification, IP66/NEMA 4X protection, and 316L stainless steel construction. It supports high-current applications, long-term reliability, and easy integration with control cabinets in oil & gas, chemical processing, and mining facilities.