Eaton Crouse-Hinds XLHS17650302 Ex-CELL Enclosure - IP66
Part Number: XLHS17650302
Manufacturer
Eaton Crouse-Hinds
Part number
XLHS17650302
Quick Summary
Ex-CELL enclosure from Eaton Crouse-Hinds protects electrical assemblies in hazardous locations for industrial automation. Engineers often struggle with corrosion, ingress and downtime when enclosures lack approved ratings and robust mounting options. It carries IECEx/ATEX, NEC/CEC, NEMA 4X and IP66 ratings, providing regulatory confidence across multiple markets. With 316L stainless steel construction and a compact 762 x 508 x 300 mm footprint, this enclosure combines durability with installation flexibility, reducing maintenance cycles and extending asset life in demanding environments. By pairing corrosion resistance with proven sealing, it supports safer, more reliable automation in hazardous sites while aligning with cost-conscious procurement goals and lifecycle planning.
Product Information
Extended Description
XLHS17650302 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 400A, 762 x 508 x 300 mm enclosure size, 563 mm horizontal fixing center, 608 mm vertical fixing center, 316L stainless steel, 2 gland plates, Horizontal lugs, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLHS17650302
EAN
4251958139717
Product Length/Depth
300 mm
Product Height
762 mm
Product Width
508 mm
Area classification
Hazardous/Classified Locations
Standards type
IEC IECEx/ATEX NEC/CEC
NEC hazardous rating
Class I, Division 2 Class II, Division 2 Class I, Zone 1
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
762 x 508 x 300 mm
Number of gland plates
2
Type
Horizontal lugs
Crouse-Hinds series Stainless Steel Enclosures Solutions brochure
Crouse-Hinds series Ex-CELL Stainless Steel or Painted Steel Enclosures catalog page
Crouse-Hinds series Ex-CELL empty enclosures - UKCA Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - UKCA Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - UKCA Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - UKCA Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - UKCA Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - UKCA Declaration of Conformity
Crouse-Hinds series Ex-CELL empty enclosures - UKCA Declaration of Conformity
ENK10673 Ex-Cell Operating Instructions
Feature: 316L stainless steel construction → Business Impact: Superior corrosion resistance and cleanability in chemical, offshore, and pharmaceutical environments → Application: Use in harsh process areas where stainless enclosures are required. Feature: Enclosure size 762 x 508 x 300 mm with 563 mm horizontal and 608 mm vertical fixing centers → Business Impact: Predictable mounting footprint and straightforward retrofits or upgrades → Application: System integrators optimizing control panels in constrained spaces. Feature: IP66 and NEMA 4X protection → Business Impact: Robust ingress protection reduces dust, water, and corrosion ingress → Application: Wet, dusty, or washdown zones across oil & gas, water treatment, and mining facilities. Feature: 2 gland plates and horizontal lugs → Business Impact: Simplified cable entry management and secure field wiring → Application: Fast, compliant field installs with reduced rework. Feature: 690 Vac/Vdc rating → Business Impact: Wide electrical compatibility supports diverse industrial controls → Application: Hazardous location power distribution and drive systems. Feature: IECEx/ATEX and NEC/CEC certifications → Business Impact: Global approval simplifies compliance across regions → Application: Multinational projects with strict regulatory requirements. Feature: 316L stainless steel compatibility with hazardous locations → Business Impact: Long service life and lower maintenance in aggressive environments → Application: Chemical plants, refineries, and mining operations. These characteristics collectively enable predictable performance, lower total cost of ownership, and smoother project execution for system integrators and maintenance teams.
Get a Quick Quote for a Eaton Crouse-Hinds XLHS17650302
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds XLHS17650302?
Enquire Now
FAQs
This model features horizontal lugs and two gland plates with fixed centers of 563 mm (horizontal) and 608 mm (vertical). Plan for compatible mounting hardware and cable entries to minimize field wiring rework. The 762 x 508 x 300 mm footprint supports standard panels while maintaining clearance for inspections and maintenance.
Yes. It is certified for hazardous/classified locations with IECEx/ATEX and NEC/CEC standards, plus IP66 ingress protection and NEMA 4X enclosure rating. These approvals enable safe operation in Class I, Division 2 and Zone 1 environments, supporting cross-border installations and compliance-driven procurement.
The enclosure measures 762 mm high, 508 mm wide, and 300 mm deep, leveraging 316L stainless steel for corrosion resistance. The material choice supports harsh environments, while the size accommodates standard control hardware and field devices with ease.
Ideal for chemical processing, oil and gas, mining, and wastewater treatment where corrosion resistance and hazardous location approvals are critical. Its robust sealing and mounting versatility make it suitable for curbside control panels, drive systems, and actuator enclosures in challenging environments.
The enclosure supports 690 Vac/Vdc, enabling compatibility with a wide range of industrial controls, drives, and sensors. Its gasketed, sealed design helps ensure safe operation of high-voltage systems in hazardous locations while simplifying integration with existing control architectures.