Eaton XLHS17660301 Ex-CELL enclosure - IP66
Part Number: XLHS17660301
Manufacturer
Eaton Crouse-Hinds
Part number
XLHS17660301
Quick Summary
Eaton XLHS17660301 Ex-CELL enclosure is a rugged stainless steel housing designed for hazardous locations and electrical control panels. This solves the pervasive challenge of protecting sensitive gear in corrosive or explosive environments where downtime and failures are costly. Key certifications including IECEx/ATEX, IP66 ingress protection, and NEMA 4X rugged rating validate safety and reliability in harsh sites. By combining 316L stainless steel with a compact footprint and a 400 A rating, this enclosure delivers scalable, compliant protection for growing automation programs and plant upgrades while reducing maintenance and replacement costs.
Product Information
Extended Description
XLHS17660301 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 400A, 762 x 610 x 300 mm enclosure size, 665 mm horizontal fixing center, 608 mm vertical fixing center, 316L stainless steel, 1 gland plate, Horizontal lugs, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLHS17660301
EAN
4251958139809
Product Length/Depth
300 mm
Product Height
762 mm
Product Width
610 mm
Area classification
Hazardous/Classified Locations
Standards type
IECEx/ATEX IEC NEC/CEC
NEC hazardous rating
Class I, Division 2 Class II, Division 2 Class I, Zone 1
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
762 x 610 x 300 mm
Number of gland plates
1
Type
Horizontal lugs
Crouse-Hinds series Stainless Steel Enclosures Solutions brochure
Crouse-Hinds series Ex-CELL Stainless Steel or Painted Steel Enclosures catalog page
Crouse-Hinds series Ex-CELL empty enclosures - Certificate of Compliance
Crouse-Hinds series Ex-CELL empty enclosures - Certificate of Compliance
Crouse-Hinds series Ex-CELL empty enclosures - Certificate of Compliance
Crouse-Hinds series Ex-CELL empty enclosures - Certificate of Compliance
Crouse-Hinds series Ex-CELL empty enclosures - Certificate of Compliance
Crouse-Hinds series Ex-CELL empty enclosures - Certificate of Compliance
Crouse-Hinds series Ex-CELL empty enclosures - Certificate of Compliance
ENK10673 Ex-Cell Operating Instructions
Feature: 316L stainless steel construction provides superior corrosion resistance and durability in chemical, offshore, and washdown environments. Business impact: longer service life, lower replacement costs, and reduced maintenance intervals. Application: robust protection for process control gear in chemical plants and oil & gas facilities. Feature: IP66 and NEMA 4X ratings offer complete protection against dust, water jets, and harsh cleaning regimes. Business impact: higher uptime in outdoor or harsh environments and improved compliance with safety standards. Application: outdoor switchgear, outdoor PLC housings, and instrumentation enclosures. Feature: Enclosure size 762 x 610 x 300 mm with 400 A, 690 VAC/VDC capability; 665 mm horizontal and 608 mm vertical fixing centers. Business impact: easy integration with large control components and flexible mounting options. Application: medium-scale electrical panels and motor control centers. Feature: 1 gland plate and horizontal lug type streamline cabling and installation. Business impact: faster installation, fewer components, and cleaner cable management. Application: controlled wiring in hazardous areas with reduced assembly steps. Feature: Area classification Hazardous/Classified Locations and IECEx/ATEX with NEC/CEC standards. Business impact: assured compliance for global projects and minimized certification risks. Application: chemical processing, mining, and power generation environments.
Get a Quick Quote for a Eaton Crouse-Hinds XLHS17660301
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds XLHS17660301?
Enquire Now
FAQs
The Ex-CELL enclosure accepts up to 400 A with 690 VAC/VDC, uses a single gland plate, and has horizontal lug wiring access. Its 762 x 610 x 300 mm footprint fits standard switchgear footprints, while 665 mm and 608 mm fixing centers simplify mounting to existing frames. Compatible with IECEx/ATEX and NEC/CEC certified environments, it reduces integration risk on global projects.
Rated for 400 A and 690 VAC/VDC, the XLHS17660301 supports high-current control circuits within a rugged enclosure. The single gland plate streamlines cabling, and the horizontal lug configuration eases terminations. These specs enable reliable integration with motor drives, MCCs, and PLCs in hazardous areas without compromising safety or compliance.
Yes. The Ex-CELL enclosure carries IECEx/ATEX standards and NEC/CEC compliance, ensuring safe operation in hazardous/classes locations. It also provides Class I, Division 2 and Zone 1 ratings, aligning with global regulatory requirements for chemical, oil & gas, and mining applications. This reduces certification risk for multi-site deployments.
IP66 protects against powerful water jets and dust ingress, while NEMA 4X adds corrosion resistance and enclosure integrity in harsh environments. Together, they guarantee reliable operation in washdown, offshore, and outdoor installations, lowering maintenance needs and extending equipment life in aggressive processes.
316L stainless steel resists corrosion for extended service life in challenging atmospheres, reducing replacement frequency. The enclosure’s robust protection, compact footprint, and single gland plate speed up installation and commissioning. Over time, this translates to lower total cost of ownership, fewer field service interventions, and a faster return on automation investments.