Eaton Crouse-Hinds XLHS17676202 Ex-CELL enclosure - IP66

Part Number: XLHS17676202
Manufacturer
Eaton Crouse-Hinds
Part number
XLHS17676202

Quick Summary

Eaton Crouse-Hinds XLHS17676202 Ex-CELL enclosure is a robust stainless steel housing designed to protect electrical gear in hazardous locations. This enclosure addresses common downtime and corrosion challenges by combining corrosion-resistant material with a proven Ex-CELL design. It carries IECEx/ATEX certifications, IP66 ingress protection, and a NEMA 4X rating, ensuring safe operation in demanding environments. The 316L stainless steel construction delivers long life in harsh chemical, humid, and wash-down scenarios, while the enclosure’s size and gland plates simplify installation and wiring. By selecting this enclosure, engineers gain a compliant, maintenance-friendly solution that reduces lifecycle costs and supports scalable electrical infrastructure in oil, gas, chemical, and mining applications.

Product Information

Extended Description

XLHS17676202 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 400A, 762 x 762 x 203 mm enclosure size, 818 mm horizontal fixing center, 608 mm vertical fixing center, 316L stainless steel, 2 gland plates, Horizontal lugs, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLHS17676202
EAN
4251958139847
Product Length/Depth
203 mm
Product Height
762 mm
Product Width
762 mm
Area classification
Hazardous/Classified Locations
Standards type
IECEx/ATEX IEC NEC/CEC
NEC hazardous rating
Class I, Zone 1 Class II, Division 2 Class I, Division 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
762 x 762 x 203 mm
Number of gland plates
2
Type
Horizontal lugs
Feature → Business Impact → Application: The 316L stainless steel construction delivers exceptional corrosion resistance, extending service life in chemical and marine environments, reducing maintenance costs and downtime for critical equipment in refineries, offshore platforms, and chemical plants. Application: Enables reliable protection of switchgear and control components where exposure to moisture, chill spray, or corrosive vapors is common. Feature → Business Impact → Application: With an enclosure size of 762 x 762 x 203 mm, and 818 mm horizontal and 608 mm vertical fixing centers, installation is faster and more repeatable across multiple skid-mounted or centralized electrical rooms. Application: Simplifies mounting of larger assemblies in power distribution and process control cabinets. Feature → Business Impact → Application: IP66 and NEMA 4X ratings provide robust ingress protection against dust and water ingress, minimizing field failures and enabling continuous operation in wash-down environments and outdoor installations. Application: Suitable for chemical plants, water treatment, and mining sites requiring rigorous enclosure protection. Feature → Business Impact → Application: Hazardous Location readiness with Area Classification and IECEx/ATEX/NEC/CEC certifications ensures regulatory compliance and reduces project risk during approvals. Application: Essential for oil & gas, petrochemical, and refinery projects where safety certifications drive project timelines. Feature → Business Impact → Application: Horizontal lugs and two gland plates streamline wiring and cable management, lowering installation time and enabling scalable wiring densities. Application: Ideal for compact, maintenance-friendly electrical enclosures in control rooms and field installations.

Get a Quick Quote for a Eaton Crouse-Hinds XLHS17676202

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds XLHS17676202? Enquire Now

FAQs

To install XLHS17676202 Ex-CELL enclosure, verify site compliance with hazardous-location codes (IECEx/ATEX, NEC/CEC), position the enclosure on a sturdy surface, and use the 818 mm horizontal and 608 mm vertical fixing centers for mounting. Fit cables through the two gland plates, ensuring gland entries are sealed to maintain IP66/NEMA 4X protection and to simplify future cable management.
Key specs include a 400 A rating, enclosure size of 762 x 762 x 203 mm, 316L stainless steel construction, IP66 ingress protection, and NEMA 4X rating, with 690 Vac/Vdc capability. The design features horizontal lugs, two gland plates, and fixed centers at 818 mm horizontally and 608 mm vertically to support clean, repeatable installation.
Yes. The Ex-CELL XLHS17676202 is built for Hazardous/Classified Locations, supporting Class I, Zone 1 and Class II, Division 2 installations. With IECEx/ATEX and NEC/CEC certifications, it provides a compliant enclosure solution for oil and gas, chemical processing, and mining environments, enabling safe, long-term operation of electrical gear in challenging sites.
It carries IECEx and ATEX certifications for Ex equipment, as well as NEC/CEC conformity, plus area classification for Hazardous/Classified Locations. The enclosure also meets IP66 ingress protection and NEMA 4X environmental ratings, ensuring robust performance against dust, water, and corrosive exposures in demanding installations. Documentation supports fast regulatory approvals.
316L stainless steel provides superior corrosion resistance, enabling longer service life in wet, salty, and chemical environments. This reduces maintenance intervals, lowers replacement costs, and improves uptime in critical operations. Combined with Ex-CELL sealing and robust design, it delivers a predictable lifecycle cost and sustained performance in challenging facilities.