Eaton Crouse-Hinds XLHS17676251 Ex-CELL enclosure - IP66

Part Number: XLHS17676251
Manufacturer
Eaton Crouse-Hinds
Part number
XLHS17676251

Quick Summary

The XLHS17676251 Ex-CELL enclosure from Eaton Crouse-Hinds protects critical electrical gear in hazardous locations. Plant engineers continually fight corrosion, dust ingress, and equipment downtime when enclosures fail in harsh environments. Certified for IECEx/ATEX, NEC/CEC hazardous locations, IP66 ingress protection, and NEMA 4X durability, it meets strict global standards for safety and reliability. Its 316L stainless steel construction, 762 x 762 x 254 mm size, and 400 A rating deliver robust performance while reducing maintenance and replacement costs. Designed with horizontal lugs, a single gland plate, and generous mounting centers, it supports quick install, easy cable routing, and scalable protection across industrial automation projects.

Product Information

Extended Description

XLHS17676251 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 400A, 762 x 762 x 254 mm enclosure size, 818 mm horizontal fixing center, 608 mm vertical fixing center, 316L stainless steel, 1 gland plate, Horizontal lugs, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLHS17676251
EAN
4251958139861
Product Length/Depth
254 mm
Product Height
762 mm
Product Width
762 mm
Area classification
Hazardous/Classified Locations
Standards type
IECEx/ATEX IEC NEC/CEC
NEC hazardous rating
Class I, Division 2 Class I, Zone 1 Class II, Division 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
762 x 762 x 254 mm
Number of gland plates
1
Type
Horizontal lugs
Feature material and corrosion resistance → Business impact: significant reduction in maintenance cycles and replacement costs due to 316L stainless steel long-term durability in chemical, water treatment, and offshore environments. Application: ideal for process automation and harsh plant interiors where wash-downs are routine. Feature ingress protection and certifications → Business impact: predictable protection against dust and water with IP66 and NEMA 4X, enabling safe operation in hazardous areas while simplifying regulatory compliance. Application: chemical processing, oil and gas, and mining facilities requiring certified enclosures. Feature enclosure size and current rating → Business impact: ample space for power distribution components and a 400 A current rating, reducing panel crowding and facilitating future upgrades. Application: control panels and feeder assemblies in medium- to high-current industrial systems. Feature mounting geometry and gland plate → Business impact: 818 mm horizontal and 608 mm vertical fixing centers streamline retrofits and alignment with existing frames, speeding installation. Application: retrofits and modular upgrades in expanding automation lines. Feature installation efficiency and documentation → Business impact: included gland plate and standard fixing centers minimize field fabrication, lowering install time and risk. Application: quick deployment in new plants or upgrades across process industries.

Get a Quick Quote for a Eaton Crouse-Hinds XLHS17676251

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds XLHS17676251? Enquire Now

FAQs

The Ex-CELL XLHS17676251 uses horizontal lugs with fixing centers of 818 mm horizontally and 608 mm vertically, allowing flexible panel integration. It includes one gland plate for cable entry and straightforward cable routing. This configuration simplifies retrofits and aligns with common industrial enclosure standards, reducing field fabrication and installation time.
This enclosure provides a 400 A current rating and IP66 ingress protection, paired with a NEMA 4X rating for rugged outdoor and indoor use. It is certified for hazardous locations under IECEx/ATEX and NEC/CEC, ensuring safe operation in Class I/Division 2, Zone 1 environments and similar classifications.
Yes. The 316L stainless steel Ex-CELL enclosure is designed for harsh chemical and hydrocarbon environments. Its IP66 and NEMA 4X protection, combined with IECEx/ATEX and NEC/CEC hazardous-location certifications, makes it well-suited for oil and gas, chemical processing, and other demanding industrial processes.
The enclosure carries IECEx/ATEX for hazardous locations, NEC/CEC classifications, IP66 ingress protection, and NEMA 4X. This combination ensures compliance across international markets and supports safe, regulatory-aligned installations in global projects.
Support materials include the ENK10673 Ex-Cell Operating Instructions, plus brochures, catalogs, and certification reports. These documents cover installation steps, wiring guidelines, compliance data, and traceability for audits, helping you deploy quickly and confidently in assembly or retrofit projects.