Eaton Crouse-Hinds XLHS19060251 Ex-CELL Enclosure - IP66
Part Number: XLHS19060251
Manufacturer
Eaton Crouse-Hinds
Part number
XLHS19060251
Quick Summary
Eaton Crouse-Hinds Ex-CELL enclosure provides rugged outdoor-ready protection for electrical assemblies in hazardous locations. Maintenance and compliance in hazardous zones demand enclosures that withstand corrosive environments while keeping internal components accessible. This model meets NEC/CEC and IECEx/ATEX standards, offers IP66 ingress protection, and NEMA 4X corrosion resistance for harsh environments. Its 316L stainless steel construction and Ex-CELL design deliver long-term durability, reducing maintenance costs and speeding installation in automation projects. Engineers benefit from modular gland plate access and horizontal lug mounting that simplify wiring in restricted spaces. Procurement teams value standardized Ex-CELL enclosures that integrate with existing Eaton-Crouse-Hinds systems and reduce part proliferation.
Product Information
Extended Description
XLHS19060251 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 400A, 914 x 610 x 250 mm enclosure size, 665 mm horizontal fixing center, 650 mm vertical fixing center, 316L stainless steel, 1 gland plate, Horizontal lugs, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLHS19060251
EAN
4251958140119
Product Length/Depth
250 mm
Product Height
914 mm
Product Width
610 mm
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IEC IECEx/ATEX
NEC hazardous rating
Class II, Division 2 Class I, Division 2 Class I, Zone 1
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
914 x 610 x 250 mm
Number of gland plates
1
Type
Horizontal lugs
Crouse-Hinds series Stainless Steel Enclosures Solutions brochure
Crouse-Hinds series Ex-CELL Stainless Steel or Painted Steel Enclosures catalog page
Crouse-Hinds series Ex-CELL empty enclosures - TRCU
Crouse-Hinds series Ex-CELL empty enclosures - TRCU
Crouse-Hinds series Ex-CELL empty enclosures - TRCU
Crouse-Hinds series Ex-CELL empty enclosures - TRCU
Crouse-Hinds series Ex-CELL empty enclosures - TRCU
Crouse-Hinds series Ex-CELL empty enclosures - TRCU
Crouse-Hinds series Ex-CELL empty enclosures - TRCU
ENK10673 Ex-Cell Operating Instructions
Feature: 316L stainless steel construction provides exceptional corrosion resistance in chemical, offshore, and other harsh environments. Business Impact: This minimizes replacement cycles and lowers lifecycle costs while maintaining equipment integrity. Application: Ideal for hazardous-location control panels and power distribution in chemical plants and oil & gas facilities. Feature: Ex-CELL enclosure design with horizontal lugs and one gland plate enables straightforward wiring and mounting. Business Impact: Reduces installation time, simplifies field wiring, and improves sealing integrity. Application: Quick-ship integration for compact automation cabinets in constrained spaces. Feature: High protection ratings IP66 and NEMA 4X, plus NEC/IECEx/ATEX compliance. Business Impact: Enhances safety, reduces risk of noncompliance, and supports regulatory approvals for global projects. Application: Enclosures for hazardous locations across refineries, mining, and petrochemical plants. Feature: Generous enclosure size and 400A rating (914 x 610 x 250 mm). Business Impact: Supports larger control gear and power distribution while maintaining accessibility. Application: OEMs and integrators deploying medium-size motor control centers in demanding environments. Feature: 1 gland plate and robust mounting compatibility streamline retrofit and upgrade cycles. Business Impact: Facilitates upgrade projects with minimal modular changes, lowering downtime. Application: Retrofit of legacy equipment in existing facilities without reworking mounting frames.
Get a Quick Quote for a Eaton Crouse-Hinds XLHS19060251
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds XLHS19060251?
Enquire Now
FAQs
The XLHS19060251 uses horizontal lugs and a single gland plate, simplifying wall or chassis mounting in restricted spaces. For installation, ensure compatible mounting centers (690 mm horizontal fix centers are typical for this type) and verify enclosure is properly grounded. The 316L stainless steel construction supports on-site welding or mechanical fastening as required by local codes.
This Ex-CELL enclosure is rated for up to 690 Vac/Vdc and provides IP66 ingress protection with a NEMA 4X rating. It is designed for hazardous/classified locations and adheres to NEC/CEC and IECEx/ATEX standards, supporting reliable operation in aggressive industrial environments such as chemical plants and offshore facilities.
Yes. The enclosure is certified for hazardous locations (Class I, Division 1/2; Zone 1) and Class II, Division 2, meeting NEC/IECEx/ATEX requirements. Its IP66/NEMA 4X ratings provide robust protection against dust, water, and corrosive atmospheres typical in oil and gas and chemical processing plants.
The Ex-CELL XLHS19060251 carries IECEx/ATEX, NEC/CEC compliance, and IP66 with NEMA 4X. These certifications indicate suitability for hazardous locations, ensure regulatory conformity across markets, and reduce the risk of noncompliance during audits or project handovers.
316L stainless steel offers superior corrosion resistance, extending service life in challenging environments and lowering maintenance frequency. The robust Ex-CELL design also simplifies inspections and upgrades, reducing downtime and total cost of ownership in automation projects.