Eaton Crouse-Hinds Ex-CELL enclosure protects critical electrical gear in hazardous industrial environments. In harsh plants, corrosion, dust ingress, and demanding maintenance schedules complicate reliability. It carries NEMA 4X and IP66 ratings, plus IECEx/ATEX and NEC/CEC certifications for hazardous and classified locations, giving operators confidence in safe operation. The 316L stainless steel construction resists harsh chemicals, while a single gland plate and horizontal lugs streamline installation and cable management. For engineers and procurement teams, this enclosure supports project timelines, compliance needs, and long-term ROI by reducing maintenance cycles and unplanned downtime. It suits offshore platforms, chemical plants, and other locations where performance and protection matters most.

Product Information

Extended Description

XLHS19076251 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-CELL enclosure, 400A, 914 x 762 x 250 mm enclosure size, 818 mm horizontal fixing center, 650 mm vertical fixing center, 316L stainless steel, 1 gland plate, ,Horizontal lugs, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series Ex-CELL enclosure
Catalog Number
XLHS19076251
EAN
4251958140201
Product Length/Depth
250 mm
Product Height
914 mm
Product Width
762 mm
Area classification
Hazardous/Classified Locations
Standards type
IEC IECEx/ATEX NEC/CEC
NEC hazardous rating
Class I, Division 2 Class I, Zone 1 Class II, Division 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
914 x 762 x 250 mm
Number of gland plates
1
Type
Horizontal lugs
Feature: 316L stainless steel construction delivers exceptional corrosion resistance in aggressive environments including salt spray, chemical processing, and high humidity. Business Impact: Extends component life, lowers maintenance costs, and reduces replacement cycles, translating into lower total cost of ownership. Application: Ideal for Ex-CELL enclosures in oil, gas, chemical plants, offshore platforms, and other hazardous locations where durable, cleanability-conscious enclosures are required. Feature: 914 x 762 x 250 mm enclosure footprint with 400 A current handling capability. Business Impact: Supports higher power and IO density without increasing cabinet footprint, delivering space efficiency and easier cable routing. Application: Control panels and switchgear housings in process plants, offshore facilities, and hazardous-area installations where space is constrained but high current is necessary. Feature: IP66 ingress protection and NEMA 4X rating provide robust protection against water, dust, and corrosion. Business Impact: Reduces downtime from washdowns and environmental exposure, improving reliability and safety. Application: Marine terminals, refineries, and chemical processing lines. Feature: 1 gland plate and horizontal lugs, plus fixed centers of 818 mm horizontal and 650 mm vertical for flexible mounting. Business Impact: Simplifies field wiring and alignment with existing frames, reduces installation time, and lowers labor costs. Application: Retrofit projects and new builds where fixed mounting patterns and neat cable runs are essential. Feature: IECEx/ATEX, NEC/CEC certifications for hazardous and classified locations. Business Impact: Maintains regulatory compliance across global sites and accelerates project approvals. Application: Projects in oil & gas, mining, and chemical industries requiring compliance. Feature: 316L stainless steel with one gland plate and horizontal-lug type enhances future expansion and serviceability. Business Impact: Enables straightforward upgrades and maintenance planning, lowering lifecycle risk. Application: Long-life enclosures in evolving control systems.

Get a Quick Quote for a Eaton Crouse-Hinds XLHS19076251

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds XLHS19076251? Enquire Now

FAQs

Yes. The Ex-CELL enclosure uses horizontal lugs and a fixed mounting center pattern (818 mm horizontal, 650 mm vertical) to align with common frame systems, simplifying retrofit projects and new installations in Zone 1/Division 2 environments.
The enclosure is made from 316L stainless steel, rated IP66 with NEMA 4X protection, and supports up to 400 A. It is certified for hazardous/classified locations under IECEx/ATEX and NEC/CEC standards, making it suitable for demanding process and offshore settings.
Ideal for oil & gas, chemical processing, refining, and marine/offshore facilities where corrosive exposure, washdowns, and strict safety regulations apply. The 316L stainless steel construction plus IECEx/ATEX and NEC/CEC certifications enable global deployment.
IECEx/ATEX certification confirms suitability for hazardous locations, NEC/CEC compliance supports North American installations, and the IP66/NEMA 4X ratings provide broad protection against water, dust, and corrosion in challenging environments.
The combination of 316L stainless steel, robust ingress protection, and a minimal gland plate configuration reduces corrosion-related maintenance, extends service life, and lowers downtime, delivering a favorable total cost of ownership for long-term industrial deployments.